ABSTRACT

The Cerebral Aneurysm Detection and Analysis (CADA) challenge was organized to support the development and benchmarking of algorithms for detecting, analyzing, and risk assessment of cerebral aneurysms in X-ray rotational angiography (3DRA) images. 109 anonymized 3DRA datasets were provided for training, and 22 additional datasets were used to test the algorithmic solutions. Cerebral aneurysm detection was assessed using the F2 score based on recall and precision, and the fit of the delivered bounding box was assessed using the distance to the aneurysm. The segmentation quality was measured using the Jaccard index and a combination of different surface distance measures. Systematic errors were analyzed using volume correlation and bias. Rupture risk assessment was evaluated using the F2 score. 158 participants from 22 countries registered for the CADA challenge. The U-Net-based detection solutions presented by the community show similar accuracy compared to experts (F2 score 0.92), with a small number of missed aneurysms with diameters smaller than 3.5 mm. In addition, the delineation of these structures, based on U-Net variations, is excellent, with a Jaccard score of 0.92. The rupture risk estimation methods achieved an F2 score of 0.71. The performance of the detection and segmentation solutions is equivalent to that of human experts. The best results are obtained in rupture risk estimation by combining different image-based, morphological, and computational fluid dynamic parameters using machine learning methods. Furthermore, we evaluated the best methods pipeline, from detecting and delineating the vessel dilations to estimating the risk of rupture. The chain of these methods achieves an F2-score of 0.70, which is comparable to applying the risk prediction to the ground-truth delineation (0.71).


Subject(s)
Intracranial Aneurysm , Algorithms , Cerebral Angiography/methods , Humans , Imaging, Three-Dimensional/methods , Intracranial Aneurysm/diagnostic imaging , X-Rays
2.
Med Image Anal ; 70: 102027, 2021 05.
Article in English | MEDLINE | ID: mdl-33740739

ABSTRACT

Lung cancer is the deadliest type of cancer worldwide and late detection is the major factor for the low survival rate of patients. Low dose computed tomography has been suggested as a potential screening tool but manual screening is costly and time-consuming. This has fuelled the development of automatic methods for the detection, segmentation and characterisation of pulmonary nodules. In spite of promising results, the application of automatic methods to clinical routine is not straightforward and only a limited number of studies have addressed the problem in a holistic way. With the goal of advancing the state of the art, the Lung Nodule Database (LNDb) Challenge on automatic lung cancer patient management was organized. The LNDb Challenge addressed lung nodule detection, segmentation and characterization as well as prediction of patient follow-up according to the 2017 Fleischner society pulmonary nodule guidelines. 294 CT scans were thus collected retrospectively at the Centro Hospitalar e Universitrio de So Joo in Porto, Portugal and each CT was annotated by at least one radiologist. Annotations comprised nodule centroids, segmentations and subjective characterization. 58 CTs and the corresponding annotations were withheld as a separate test set. A total of 947 users registered for the challenge and 11 successful submissions for at least one of the sub-challenges were received. For patient follow-up prediction, a maximum quadratic weighted Cohen's kappa of 0.580 was obtained. In terms of nodule detection, a sensitivity below 0.4 (and 0.7) at 1 false positive per scan was obtained for nodules identified by at least one (and two) radiologist(s). For nodule segmentation, a maximum Jaccard score of 0.567 was obtained, surpassing the interobserver variability. In terms of nodule texture characterization, a maximum quadratic weighted Cohen's kappa of 0.733 was obtained, with part solid nodules being particularly challenging to classify correctly. Detailed analysis of the proposed methods and the differences in performance allow to identify the major challenges remaining and future directions - data collection, augmentation/generation and evaluation of under-represented classes, the incorporation of scan-level information for better decision-making and the development of tools and challenges with clinical-oriented goals. The LNDb Challenge and associated data remain publicly available so that future methods can be tested and benchmarked, promoting the development of new algorithms in lung cancer medical image analysis and patient follow-up recommendation.


Subject(s)
Lung Neoplasms , Solitary Pulmonary Nodule , Algorithms , Databases, Factual , Humans , Lung Neoplasms/diagnostic imaging , Retrospective Studies , Tomography, X-Ray Computed