Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 23
Filter
1.
Anesthesiology ; 2024 Apr 01.
Article in English | MEDLINE | ID: mdl-38557791

ABSTRACT

BACKGROUND: The Hypotension Prediction Index (the index) software is a machine learning algorithm that detects physiological changes that may lead to hypotension. The original validation used a case control (backwards) analysis that has been suggested to be biased. We therefore conducted a cohort (forwards) analysis and compared this to the original validation technique. METHODS: We conducted a retrospective analysis of data from previously reported studies. All data were analysed identically with 2 different methodologies and receiver operating characteristic curves (ROC) constructed. Both backwards and forwards analyses were performed to examine differences in area under the ROC for HPI and other haemodynamic variables to predict a MAP < 65mmHg for at least 1 minute 5, 10 and 15 minutes in advance. RESULTS: Two thousand and twenty-two patients were included in the analysis, yielding 4,152,124 measurements taken at 20 second intervals. The area-under-the-curve for the index predicting hypotension analysed by backward and forward methodologies respectively was 0.957 (95% CI, 0.947-0.964) vs 0.923 (95% CI, 0.912-0.933) 5 minutes in advance, 0.933 (95% CI, 0.924-0.942) vs 0.923 (95% CI, 0.911-0.933) 10 minutes in advance , and 0.929 (95% CI, 0.918-0.938) vs. 0.926 (95% CI, 0.914-0.937) 15 minutes in advance. No other variable had an area-under-the-curve > 0.7 except for MAP. Area-under-the-curve using forward analysis for MAP predicting hypotension 5, 10, and 15 minutes in advance was 0.932 (95% CI, 0.920-0.940), 0.929 (95% CI, 0.918-0.938), and 0.932 (95% CI, 0.921-0.940). The R 2 for the variation in the index due to MAP was 0.77. CONCLUSION: Using an updated methodology, we found the utility of the HPI index to predict future hypotensive events is high, with an area under the receiver-operating-characteristics curve similar to that of the original validation method.

2.
Physiol Rep ; 11(4): e15607, 2023 02.
Article in English | MEDLINE | ID: mdl-36808901

ABSTRACT

Left ventricular mechanical dyssynchrony (LVMD) refers to the nonuniformity in mechanical contraction and relaxation timing in different ventricular segments. We aimed to determine the relationship between LVMD and LV performance, as assessed by ventriculo-arterial coupling (VAC), LV mechanical efficiency (LVeff ), left ventricular ejection fraction (LVEF), and diastolic function during sequential experimental changes in loading and contractile conditions. Thirteen Yorkshire pigs submitted to three consecutive stages with two opposite interventions each: changes in afterload (phenylephrine/nitroprusside), preload (bleeding/reinfusion and fluid bolus), and contractility (esmolol/dobutamine). LV pressure-volume data were obtained with a conductance catheter. Segmental mechanical dyssynchrony was assessed by global, systolic, and diastolic dyssynchrony (DYS) and internal flow fraction (IFF). Late systolic LVMD was related to an impaired VAC, LVeff , and LVEF, whereas diastolic LVMD was associated with delayed LV relaxation (logistic tau), decreased LV peak filling rate, and increased atrial contribution to LV filling. The hemodynamic factors related to LVMD were contractility, afterload, and heart rate. However, the relationship between these factors differed throughout the cardiac cycle. LVMD plays a significant role in LV systolic and diastolic performance and is associated with hemodynamic factors and intraventricular conduction.


Subject(s)
Ventricular Dysfunction, Left , Ventricular Function, Left , Animals , Swine , Ventricular Function, Left/physiology , Stroke Volume , Systole/physiology , Diastole , Nitroprusside
3.
J Clin Monit Comput ; 37(2): 651-659, 2023 04.
Article in English | MEDLINE | ID: mdl-36335548

ABSTRACT

To investigate if the Hypotension Prediction Index was an early indicator of haemodynamic instability in a negative inotropy porcine model, and to assess the correlation of commonly measured indicators of left ventricular systolic function. Eight anaesthetised pigs were volume resuscitated and then underwent an incremental infusion of esmolol hydrochloride (0-3000 mg/hr), following which it was then reduced in a stepwise manner. Full haemodynamic measurements were taken at each stage and measurements of left ventricular systolic function including left ventricular stroke work index, ejection fraction and peripheral dP/dT were obtained. At an infusion rate of 500 mg/hr of esmolol there were no significant changes in any measured variables. At 1000 mg/hr MAP was on average 11 mmHg lower (95% CI 1 to 11 mmHg, p = 0.027) with a mean of 78 mmHg, HPI increased by 33 units (95% CI 4 to 62, p = 0.026) with a mean value of 63. No other parameters showed significant change from baseline values. Subsequent increases in esmolol showed changes in all parameters except SVV, SVR and PA mean. Correlation between dP/dt and LVSWI was 0.85 (95% CI 0.77 to 0.90, p < 0.001), between LVEF and dP/dt 0.39 (95% CI 0.18 to 0.57, p < 0.001), and between LSWI and LVEF 0.41 (95% CI 0.20 to 0.59, p < 0.001). In this model haemodynamic instability induced by negative inotropy was detected by the HPI algorithm prior to any clinically significant change in commonly measured variables. In addition, the peripheral measure of left ventricular contractility dP/dt correlates well with more established measurements of LV systolic function.


Subject(s)
Propanolamines , Ventricular Function, Left , Animals , Swine , Propanolamines/pharmacology , Systole , Hemodynamics , Myocardial Contraction
4.
Cureus ; 13(8): e17610, 2021 Aug.
Article in English | MEDLINE | ID: mdl-34646661

ABSTRACT

Invasive intraarterial blood pressure measurement is currently the gold standard for intraoperative hemodynamic monitoring but accurate systolic blood pressure (SBP) measurement is difficult in everyday clinical practice, mostly because of problems with hyper-resonance or damping within the measurement system, which can lead to erroneous treatment decisions if these phenomena are not recognized. A hyper-resonant blood pressure trace significantly overestimates true systolic blood pressure while underestimating the diastolic pressure. Invasively measured systolic blood pressure is also significantly more affected than mean blood pressure by the site of measurement within the arterial system. Patients in the intraoperative period should be treated based on the invasively measured mean blood pressure rather than the systolic blood pressure. In this review, we discuss the pros/cons, mechanisms of invasive blood pressure measurements, and the interpretation of the invasively measured systolic blood pressure value.

6.
J Clin Monit Comput ; 35(1): 71-78, 2021 Feb.
Article in English | MEDLINE | ID: mdl-31989416

ABSTRACT

An algorithm derived from machine learning uses the arterial waveform to predict intraoperative hypotension some minutes before episodes, possibly giving clinician's time to intervene and prevent hypotension. Whether the Hypotension Prediction Index works well with noninvasive arterial pressure waveforms remains unknown. We therefore evaluated sensitivity, specificity, and positive predictive value of the Index based on non-invasive arterial waveform estimates. We used continuous hemodynamic data measured from ClearSight (formerly Nexfin) noninvasive finger blood pressure monitors in surgical patients. We re-evaluated data from a trial that included 320 adults ≥ 45 years old designated ASA physical status 3 or 4 who had moderate-to-high-risk non-cardiac surgery with general anesthesia. We calculated sensitivity and specificity for predicting hypotension, defined as mean arterial pressure ≤ 65 mmHg for at least 1 min, and characterized the relationship with receiver operating characteristics curves. We also evaluated the number of hypotensive events at various ranges of the Hypotension Prediction Index. And finally, we calculated the positive predictive value for hypotension episodes when the Prediction Index threshold was 85. The algorithm predicted hypotension 5 min in advance, with a sensitivity of 0.86 [95% confidence interval 0.82, 0.89] and specificity 0.86 [0.82, 0.89]. At 10 min, the sensitivity was 0.83 [0.79, 0.86] and the specificity was 0.83 [0.79, 0.86]. And at 15 min, the sensitivity was 0.75 [0.71, 0.80] and the specificity was 0.75 [0.71, 0.80]. The positive predictive value of the algorithm prediction at an Index threshold of 85 was 0.83 [0.79, 0.87]. A Hypotension Prediction Index of 80-89 provided a median of 6.0 [95% confidence interval 5.3, 6.7] minutes warning before mean arterial pressure decreased to < 65 mmHg. The Hypotension Prediction Index, which was developed and validated with invasive arterial waveforms, predicts intraoperative hypotension reasonably well from non-invasive estimates of the arterial waveform. Hypotension prediction, along with appropriate management, can potentially reduce intraoperative hypotension. Being able to use the non-invasive pressure waveform will widen the range of patients who might benefit.Clinical Trial Number: ClinicalTrials.gov NCT02872896.


Subject(s)
Arterial Pressure , Hypotension , Adult , Humans , Hypotension/diagnosis , Machine Learning , Middle Aged , Predictive Value of Tests , Sensitivity and Specificity
7.
Front Physiol ; 11: 284, 2020.
Article in English | MEDLINE | ID: mdl-32327999

ABSTRACT

Dynamic arterial elastance (Eadyn), the ratio between arterial pulse pressure and stroke volume changes during respiration, has been postulated as an index of the coupling between the left ventricle (LV) and the arterial system. We aimed to confirm this hypothesis using the gold-standard for defining LV contractility, afterload, and evaluating ventricular-arterial (VA) coupling and LV efficiency during different loading and contractile experimental conditions. Twelve Yorkshire healthy female pigs submitted to three consecutive stages with two opposite interventions each: changes in afterload (phenylephrine/nitroprusside), preload (bleeding/fluid bolus), and contractility (esmolol/dobutamine). LV pressure-volume data was obtained with a conductance catheter, and arterial pressures were measured via a fluid-filled catheter in the proximal aorta and the radial artery. End-systolic elastance (Ees), a load-independent index of myocardial contractility, was calculated during an inferior vena cava occlusion. Effective arterial elastance (Ea, an index of LV afterload) was calculated as LV end-systolic pressure/stroke volume. VA coupling was defined as the ratio Ea/Ees. LV efficiency (LVeff) was defined as the ratio between stroke work and the LV pressure-volume area. Eadyn was calculated as the ratio between the aortic pulse pressure variation (PPV) and conductance-derived stroke volume variation (SVV). A linear mixed model was used for evaluating the relationship between Ees, Ea, VA coupling, LVeff with Eadyn. Eadyn was inversely related to VA coupling and directly to LVeff. The higher the Eadyn, the higher the LVeff and the lower the VA coupling. Thus, Eadyn, an easily measured parameter at the bedside, may be of clinical relevance for hemodynamic assessment of the unstable patient.

8.
Anesth Analg ; 130(2): 352-359, 2020 02.
Article in English | MEDLINE | ID: mdl-30896602

ABSTRACT

BACKGROUND: Intraoperative hypotension is associated with worse perioperative outcomes for patients undergoing major noncardiac surgery. The Hypotension Prediction Index is a unitless number that is derived from an arterial pressure waveform trace, and as the number increases, the risk of hypotension occurring in the near future increases. We investigated the diagnostic ability of the Hypotension Prediction Index in predicting impending intraoperative hypotension in comparison to other commonly collected perioperative hemodynamic variables. METHODS: This is a 2-center retrospective analysis of patients undergoing major surgery. Data were downloaded and analyzed from the Edwards Lifesciences EV1000 platform. Receiver operating characteristic curves were constructed for the Hypotension Prediction Index and other hemodynamic variables as well as event rates and time to event. RESULTS: Two hundred fifty-five patients undergoing major surgery were included in the analysis yielding 292,025 data points. The Hypotension Prediction Index predicted hypotension with a sensitivity and specificity of 85.8% (95% CI, 85.8%-85.9%) and 85.8% (95% CI, 85.8%-85.9%) 5 minutes before a hypotensive event (area under the curve, 0.926 [95% CI, 0.925-0.926]); 81.7% (95% CI, 81.6%-81.8%) and 81.7% (95% CI, 81.6%-81.8%) 10 minutes before a hypotensive event (area under the curve, 0.895 [95% CI, 0.894-0.895]); and 80.6% (95% CI, 80.5%-80.7%) and 80.6% (95% CI, 80.5%-80.7%) 15 minutes before a hypotensive event (area under the curve, 0.879 [95% CI, 0.879-0.880]). The Hypotension Prediction Index performed superior to all other measured hemodynamic variables including mean arterial pressure and change in mean arterial pressure over a 3-minute window. CONCLUSIONS: The Hypotension Prediction Index provides an accurate real time and continuous prediction of impending intraoperative hypotension before its occurrence and has superior predictive ability than the commonly measured perioperative hemodynamic variables.


Subject(s)
Arterial Pressure/physiology , Hypotension/diagnosis , Hypotension/physiopathology , Intraoperative Complications/diagnosis , Intraoperative Complications/physiopathology , Monitoring, Intraoperative/methods , Aged , Aged, 80 and over , Female , Forecasting , Humans , Male , Middle Aged , Predictive Value of Tests , Prospective Studies , Retrospective Studies
9.
Ann Intensive Care ; 9(1): 48, 2019 Apr 16.
Article in English | MEDLINE | ID: mdl-30993544

ABSTRACT

BACKGROUND: The aim of this study was to quantify the impact of different cardiovascular factors on left ventricular ejection fraction (LVEF) and test a novel LVEF calculation considering these factors. RESULTS: 10 pigs were studied. The experimental protocol consisted of sequentially changing afterload, preload and contractility. LV pressure-volume (PV) loops and peripheral arterial pressure were obtained before and after each intervention. LVEF was calculated as stroke volume (SV)/end-diastolic volume (EDV). We studied global cardiac function variables: LV end-systolic elastance (Ees), effective arterial elastance (Ea), end-diastolic volume and heart rate. Diastolic function was evaluated by means of the ventricular relaxation time (τ) and ventricular stiffness constant (ß) obtained from the end-diastolic PV relationship. Ventriculo-arterial coupling (VAC), an index of cardiovascular performance, was calculated as Ea/Ees. LV mechanical efficiency (LVeff) was calculated as the ratio of stroke work to LV pressure-volume area. A linear mixed model was used to determine the impact of cardiac factors (Ees, Ea, EDV and heart rate), VAC and LVeff on LVEF during all experimental conditions. LVEF was mainly related to Ees and Ea. There was a strong relationship between LVEF and both VAC and LVeff (r2 = 0.69 and r2 = 0.94, respectively). The relationship between LVEF and Ees was good (r2 = 0.43). Adjusting LVEF to afterload ([Formula: see text]) performed better for estimating Ees (r2 = 0.75) and improved the tracking of LV contractility changes, even when a peripheral Ea was used as surrogate (Ea = radial MAP/SV; r2 = 0.73). CONCLUSIONS: LVEF was mainly affected by contractility and afterload changes and was strongly related to VAC and LVeff. An adjustment to LVEF that considers the impact of afterload provided a better assessment of LV contractility.

11.
J Clin Monit Comput ; 33(5): 803-813, 2019 Oct.
Article in English | MEDLINE | ID: mdl-30552525

ABSTRACT

To compare the effective arterial elastance (Ea) obtained from the arterial pressure with Ea calculated from left-ventricular (LV) pressure-volume analysis. Experimental study. LV pressure-volume data was obtained with a conductance catheter and arterial pressures were measured via a fluid-filled catheter placed in the proximal aorta, femoral and radial arteries. Ea was calculated as LV end-systolic pressure (ESP)/stroke volume (SV). Experimental protocol consisted sequentially changing afterload (phenylephrine/nitroprusside), preload (bleeding/fluid), and contractility (esmolol/dobutamine). 90% of systolic pressure (Eaao_SYS, Eafem_SYS, Earad_SYS), mean arterial pressure (Eaao_MAP, Eafem_MAP, Earad_MAP), and dicrotic notch pressure (Eaao_DIC, Eafem_DIC, Earad_DIC) were used as surrogates for LV ESP. SV was calculated from the LV pressure-volume data. When Ea was compared with estimations based on 90% SAP, the relationship was r2 = 0.95, 0.94 and 0.92; and the bias and limits of agreement (LOA): - 0.01 ± 0.12, - 0.09 ± 0.12, - 0.05 ± 0.15 mmHg ml-1, for Eaao_SYS, Eafem_SYS and Earad_SYS, respectively. For estimates using dicrotic notch, the relationship was r2 = 0.94, 0.95 and 0.94 for Eaao_DIC, Eafem_DIC and Earad_DIC, respectively; with a bias and LOA: 0.05 ± 0.11, 0.06 ± 0.12, 0.10 ± 0.12 mmHg ml-1, respectively. When Ea was compared with estimates using MAP, the relationship was r2 = 0.95, 0.96 and 0.95 for Eaao_MAP, Eafem_MAP and Earad_MAP, respectively; with a bias and LOA: 0.05 ± 0.11, 0.06 ± 0.11, 0.06 ± 0.11 mmHg ml-1, respectively. LV ESP can be estimated from the arterial pressure. Provided that the SV measurement is reliable, the ratio MAP/SV provides a robust Ea surrogate over a wide range of hemodynamic conditions and is interchangeably in any peripheral artery, so it should be recommended as an arterial estimate of Ea in further research.


Subject(s)
Arterial Pressure , Heart Ventricles/physiopathology , Monitoring, Intraoperative/instrumentation , Systole , Animals , Calibration , Cardiac Output , Catheterization , Dobutamine/pharmacology , Elasticity , Hemodynamics , Hemorrhage , Linear Models , Monitoring, Intraoperative/methods , Nitroprusside/pharmacology , Phenylephrine/pharmacology , Pressure , Propanolamines/pharmacology , Regression Analysis , Stroke Volume , Swine , Ventricular Function, Left
12.
Crit Care ; 22(1): 325, 2018 11 29.
Article in English | MEDLINE | ID: mdl-30486866

ABSTRACT

BACKGROUND: Maximal left ventricular (LV) pressure rise (LV dP/dtmax), a classical marker of LV systolic function, requires LV catheterization, thus surrogate arterial pressure waveform measures have been proposed. We compared LV and arterial (femoral and radial) dP/dtmax to the slope of the LV end-systolic pressure-volume relationship (Ees), a load-independent measure of LV contractility, to determine the interactions between dP/dtmax and Ees as loading and LV contractility varied. METHODS: We measured LV pressure-volume data using a conductance catheter and femoral and radial arterial pressures using a fluid-filled catheter in 10 anesthetized pigs. Ees was calculated as the slope of the end-systolic pressure-volume relationship during a transient inferior vena cava occlusion. Afterload was assessed by the effective arterial elastance. The experimental protocol consisted of sequentially changing afterload (phenylephrine/nitroprusside), preload (bleeding/fluid bolus), and contractility (esmolol/dobutamine). A linear-mixed analysis was used to assess the contribution of cardiac (Ees, end-diastolic volume, effective arterial elastance, heart rate, preload-dependency) and arterial factors (total vascular resistance and arterial compliance) to LV and arterial dP/dtmax. RESULTS: Both LV and arterial dP/dtmax allowed the tracking of Ees changes, especially during afterload and contractility changes, although arterial dP/dtmax was lower compared to LV dP/dtmax (bias 732 ± 539 mmHg⋅s- 1 for femoral dP/dtmax, and 625 ± 501 mmHg⋅s- 1 for radial dP/dtmax). Changes in cardiac contractility (Ees) were the main determinant of LV and arterial dP/dtmax changes. CONCLUSION: Although arterial dP/dtmax is a complex function of central and peripheral arterial factors, radial and particularly femoral dP/dtmax allowed reasonably good tracking of LV contractility changes as loading and inotropic conditions varied.


Subject(s)
Ventricular Function, Left/physiology , Weights and Measures/standards , Adrenergic beta-1 Receptor Antagonists/therapeutic use , Animals , Cardiotonic Agents/therapeutic use , Catheterization, Central Venous/methods , Myocardial Contraction/physiology , Nitroprusside/therapeutic use , Phenylephrine/therapeutic use , Propanolamines/therapeutic use , Swine , Vasodilator Agents/therapeutic use
13.
Anesthesiology ; 129(4): 663-674, 2018 10.
Article in English | MEDLINE | ID: mdl-29894315

ABSTRACT

WHAT WE ALREADY KNOW ABOUT THIS TOPIC: WHAT THIS ARTICLE TELLS US THAT IS NEW: BACKGROUND:: With appropriate algorithms, computers can learn to detect patterns and associations in large data sets. The authors' goal was to apply machine learning to arterial pressure waveforms and create an algorithm to predict hypotension. The algorithm detects early alteration in waveforms that can herald the weakening of cardiovascular compensatory mechanisms affecting preload, afterload, and contractility. METHODS: The algorithm was developed with two different data sources: (1) a retrospective cohort, used for training, consisting of 1,334 patients' records with 545,959 min of arterial waveform recording and 25,461 episodes of hypotension; and (2) a prospective, local hospital cohort used for external validation, consisting of 204 patients' records with 33,236 min of arterial waveform recording and 1,923 episodes of hypotension. The algorithm relates a large set of features calculated from the high-fidelity arterial pressure waveform to the prediction of an upcoming hypotensive event (mean arterial pressure < 65 mmHg). Receiver-operating characteristic curve analysis evaluated the algorithm's success in predicting hypotension, defined as mean arterial pressure less than 65 mmHg. RESULTS: Using 3,022 individual features per cardiac cycle, the algorithm predicted arterial hypotension with a sensitivity and specificity of 88% (85 to 90%) and 87% (85 to 90%) 15 min before a hypotensive event (area under the curve, 0.95 [0.94 to 0.95]); 89% (87 to 91%) and 90% (87 to 92%) 10 min before (area under the curve, 0.95 [0.95 to 0.96]); 92% (90 to 94%) and 92% (90 to 94%) 5 min before (area under the curve, 0.97 [0.97 to 0.98]). CONCLUSIONS: The results demonstrate that a machine-learning algorithm can be trained, with large data sets of high-fidelity arterial waveforms, to predict hypotension in surgical patients' records.


Subject(s)
Algorithms , Arterial Pressure/physiology , Hypotension/diagnosis , Hypotension/physiopathology , Machine Learning , Wavelet Analysis , Adult , Aged , Aged, 80 and over , Female , Humans , Male , Middle Aged
14.
J Appl Physiol (1985) ; 113(2): 281-9, 2012 Jul.
Article in English | MEDLINE | ID: mdl-22556399

ABSTRACT

INTRODUCTION: phenylephrine is used daily during anesthesia for treating hypotension. However, the effects of phenylephrine on cardiac output (CO) are not clear. We hypothesized that the impact of phenylephrine on cardiac output is related to preload dependency. METHODS: eight pigs were studied at a preload independent stage (after CO augmentation) and at a preload dependent stage (after a 21 ml/kg hemorrhage). At each stage, phenylephrine boluses (0.5, 1.0, 2.0, and 4.0 µg/kg) were given randomly while mean arterial pressure (MAP), CO, inferior vena cava flow (IVCf) (both measured using ultrasonic flow probes), and pulse pressure variation were measured. RESULTS: at the preload independent stage, phenylephrine boluses induced significant increases in MAP (from 72 ± 6 to 100 ± 6 mmHg; P < 0.05) and decreases in CO and IVCf (from 7.0 ± 0.8 to 6.0 ± 1.1 l/min and from 4.6 ± 0.5 to 3.8 ± 0.6 l/min, respectively). At the preload-dependent stage, phenylephrine boluses induced significant increases in MAP (from 40 ± 7 to 65 ± 9 mmHg), CO (from 4.1 ± 0.6 to 4.9 ± 0.7 l/min), and IVCf (from 3.0 ± 0.4 to 3.5 ± 0.6 l/min; all data presented are for 4 µg/kg). Incremental doses of phenylephrine induced incremental changes in cardiac output. A pulse pressure variation >16.4% before phenylephrine predicted an increase in stroke volume with a 93% sensitivity and a 100% specificity. CONCLUSION: impact of phenylephrine on cardiac output is related to preload dependency. When the heart is preload independent, phenylephrine boluses induce on average a decrease in cardiac output. When the heart is preload dependent, phenylephrine boluses induce on average an increase in cardiac output.


Subject(s)
Cardiac Output/drug effects , Cardiac Output/physiology , Phenylephrine/administration & dosage , Posture/physiology , Stroke Volume/drug effects , Stroke Volume/physiology , Veins/physiology , Animals , Cardiotonic Agents , Dose-Response Relationship, Drug , Swine , Veins/drug effects
15.
Opt Express ; 18(2): 1024-32, 2010 Jan 18.
Article in English | MEDLINE | ID: mdl-20173923

ABSTRACT

Optical coherence tomography is an emerging non-invasive technology that provides high resolution, cross-sectional tomographic images of internal structures of specimens. OCT images, however, are usually degraded by significant speckle noise. Here we introduce to our knowledge the first 3D approach to attenuating speckle noise in OCT images. Unlike 2D approaches which only consider information in individual images, 3D processing, by analyzing all images in a volume simultaneously, has the advantage of also taking the information between images into account. This, coupled with the curvelet transform's nearly optimal sparse representation of curved edges that are common in OCT images, provides a simple yet powerful platform for speckle attenuation. We show the approach suppresses a significant amount of speckle noise, while in the mean time preserves and thus reveals many subtle features that could get attenuated in other approaches.


Subject(s)
Algorithms , Artifacts , Image Enhancement/methods , Image Interpretation, Computer-Assisted/methods , Tomography, Optical Coherence/methods , Reproducibility of Results , Sensitivity and Specificity
16.
Opt Lett ; 34(10): 1516-8, 2009 May 15.
Article in English | MEDLINE | ID: mdl-19448806

ABSTRACT

We describe an algorithm based on shrinkage in the curvelet domain to attenuate speckles in optical coherence tomography (OCT) images. The algorithm exploits the curvelet transform's sparse representation of edge discontinuities that are common in OCT images and its ability to map signals and noise into different areas in the curvelet domain. The speckle attenuation is controlled by a single parameter that determines the threshold in the curvelet domain. Applying the algorithm to OCT images shows significant improvement of image quality.


Subject(s)
Image Processing, Computer-Assisted/methods , Tomography, Optical Coherence/methods , Algorithms , Fourier Analysis , Tomography, Optical Coherence/standards
17.
Opt Lett ; 32(6): 683-5, 2007 Mar 15.
Article in English | MEDLINE | ID: mdl-17308601

ABSTRACT

We report an experimental demonstration of the superprism effect in a photonic crystal slab at terahertz frequencies. For a 10% frequency variation around 0.28 THz, the refraction angle at the output facet of a wedge-shaped photonic crystal varies by about 15 degrees. A comparison with the predictions of a band structure calculation demonstrates that a three-dimensional treatment, accurately modeling the finite slab thickness and the metallic boundary conditions, is required for even a qualitative agreement with the experimental observations.

18.
Opt Lett ; 30(21): 2843-5, 2005 Nov 01.
Article in English | MEDLINE | ID: mdl-16279444

ABSTRACT

We develop a closed-form expression for the probability distribution function for the field components of a diffusive broadband wave propagating through a random medium. We consider each spectral component to provide an individual observation of a random variable, the configurationally averaged spectral intensity. Since the intensity determines the variance of the field distribution at each frequency, this random variable serves as the Bayesian prior that determines the form of the non-Gaussian field statistics. This model agrees well with experimental results.

19.
Opt Lett ; 29(17): 2067-9, 2004 Sep 01.
Article in English | MEDLINE | ID: mdl-15455782

ABSTRACT

We describe broadband coherent transmission studies of two-dimensional photonic crystals consisting of a hexagonal array of air holes in a dielectric slab in a planar waveguide. By filling several of the air holes in the photonic crystal slab, we observe the signature of a defect mode within the stop band, in both the amplitude and phase spectra. The experimental results are in reasonable agreement with theoretical calculations using the transfer matrix method.

20.
Philos Trans A Math Phys Eng Sci ; 362(1815): 301-13; discussion 313-4, 2004 Feb 15.
Article in English | MEDLINE | ID: mdl-15306521

ABSTRACT

We describe measurements of single-cycle terahertz pulse propagation in a random medium. The unique capabilities of terahertz time-domain spectroscopy permit the characterization of a multiply scattered field with unprecedented spatial and temporal resolution. With these results, we can develop a framework for understanding the statistics of broadband laser speckle. Also, the ability to extract information on the phase of the field opens up new possibilities for characterizing multiply scattered waves. We illustrate this with a simple example, which involves computing a time-windowed temporal correlation between fields measured at different spatial locations. This enables the identification of individual scattering events, and could lead to a new method for imaging in random media.

SELECTION OF CITATIONS
SEARCH DETAIL
...