Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 2 de 2
Filter
Add more filters










Database
Publication year range
1.
Guang Pu Xue Yu Guang Pu Fen Xi ; 33(5): 1327-30, 2013 May.
Article in Chinese | MEDLINE | ID: mdl-23905345

ABSTRACT

To develop a spectrophotometric method for determining the concentration of recombinant hirudin (rH) in urine of rats. rH concentration was determined based on the rH inhibility to thrombin which hydrolyzed the Chromozym TH TH chromogenic substrate to form the specific pNA absorbed at 405 nm. The standard rH in rat urine was determined by the spectrophotometric method at concentration of 6.25 to 75 ng x mL(-1) with day and intra-day RSD < 10%, method recoveries of > 95% and the dilution recoveries of > 93%. The rH samples of rat urines which iv dose of 0.5, 1.0, and 2.0 mg x kg(-1) were collected and analyzed by the CSA method. Their cumulative excretion rH at 0-12 hr were (116.850 +/- 57.160), (235.544 +/- 39.375) and (474.986 +/- 85.426) microg x kg(-1). The calculated cumulative excretion rate of three doses is about 23% which indicates that the rH was eliminated in the way of a linear kinetics in rats. The rH content in rat urine could be measured by the spectrophotometric method accurately, reliably and sensitively for the rH urinary excretion dynamics study.


Subject(s)
Hirudins/urine , Recombinant Proteins/urine , Spectrophotometry/methods , Animals , Hirudins/administration & dosage , Injections, Intravenous , Male , Rats , Rats, Sprague-Dawley , Recombinant Proteins/administration & dosage
2.
PLoS One ; 8(6): e64336, 2013.
Article in English | MEDLINE | ID: mdl-23785400

ABSTRACT

AIM: To compare the analytical methods used to study the pharmacokinetics of recombinant hirudin in the plasma of rats that had been injected with (125)I-recombinant hirudin. METHODS: 2.0 mg/kg (125)I-recombinant hirudin were injected intravenously into rats. The recombinant hirudins in the plasma was analyzed by chromogenic substrate assay, enzyme-linked immunosorbent assay (ELISA), total radioisotope assay (RA) and trichloroacetic acid pre-treated total radioisotope assay (TCA-RA). RESULTS: The chromogenic substrate assay standard curve was linear over the concentration range from 3.12 to 40.00 ng/ml for the recombinant hirudin in plasma. The relative standard deviations (RSD) for the intra- and inter-day variation were 5.0 to 6.3% and 11.9 to 12.6%, respectively. The recoveries of recombinant hirudin was 89.8% to 100.7%. The limit of quantification (LOQ) was 3.12 ng/ml. The concentration-time curve of the recombinant hirudin in the plasma could be explained as a two-compartment model. Pharmacokinetic parameters, including the half-life of distribution phase (t1/2 α), the half-life of elimination phase (t1/2 ß), volume of apparent distribution (Vd), and area under the concentration-time curve from zero to infinite time (AUC0-t) were 7.59 min, 46.99 min, 0.17 L/kg, and 204.5 mg/L/min, respectively, as determined by chromogenic substrate assay; 6.41 min, 47.28 min, 1.24 L/kg, and 575.18 mg/L/min, respectively, as determined by ELISA; 3.69 min, 701.90 min, 0.04 L/kg, and 4189 mg/L/min, respectively as determined by RA; and 4.57 min, 724.9 min, 0.09 L/kg, and 2329 mg/L/min, respectively, as determined by TCA-RA. CONCLUSIONS: The chromogenic substrate assay on the concentration dynamics of the recombinant hirudin in the plasma is a specific, sensitive, and accurate analytical method for pharmacokinetic studies. Moreover, the pharmacokinetic parameters determined by the chromogenic substrate assay and ELISA are congruent except for AUC.


Subject(s)
Fibrinolytic Agents/pharmacokinetics , Hirudins/pharmacokinetics , Recombinant Proteins/pharmacokinetics , Animals , Chromogenic Compounds , Enzyme-Linked Immunosorbent Assay , Fibrinolytic Agents/blood , Hirudins/blood , Male , Radioisotopes , Rats , Recombinant Proteins/blood , Reproducibility of Results
SELECTION OF CITATIONS
SEARCH DETAIL
...