Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 82
Filter
1.
J Sex Med ; 21(6): 511-521, 2024 May 28.
Article in English | MEDLINE | ID: mdl-38477100

ABSTRACT

BACKGROUND: Erectile dysfunction (ED), defined as the inability to achieve or maintain a penile erection sufficient to satisfy sexual behavior, is prevalent worldwide. AIM: Using previous research, bioinformatics, and experimental confirmation, we aimed to discover genes that contribute to ED through regulating hypoxia in corpus cavernosum smooth muscle cells (CCSMCs). METHODS: We used the Gene Expression Omnibus to acquire the sequencing data of the corpus cavernosum transcriptome for diabetic ED and nerve injury type ED rats. We intersected the common differentially expressed genes. Further verification was performed using single cell sequencing. Real-time quantitative polymerase chain reaction and immunofluorescence were used to investigate whether the differentially expressed genes are found in the corpus cavernosum. We used induced hypoxia to assess cell viability changes, and we developed a lentivirus overexpressing Cldn4 for in vitro and in vivo experiments to measure changes in JNK signaling, fibrosis, hypoxia, and erectile function. OUTCOMES: Our results indicate that targeting the JNK pathway and decreasing local hypoxia may be better options for therapeutic intervention to improve erectile function. RESULTS: We identified Cldn4 and found its expression increased in the corpora cavernosa of the 2 datasets. In addition, we found that hypoxia can increase the expression of Cldn4, activate the JNK signaling pathway, and exacerbate fibrosis in CCSMCs. Cldn4 overexpression in CCSMCs activated the JNK signaling pathway and increased fibrotic protein expression. Last, rat corpus cavernosum overexpressing Cldn4 activated the JNK signaling pathway, increased local fibrosis, and impaired erectile function. CLINICAL IMPLICATIONS: Through bioinformatics and in vitro and in vivo experiments, we found that Cldn4 has a negative effect on ED, and targeting Cldn4 may provide new ideas for ED treatment. STRENGTHS AND LIMITATIONS: Although we have identified Cldn4 as a potential target for ED treatment, we have only conducted preliminary validation on CCMSCs, and we still need to further validate in other cell lines. CONCLUSION: CCSMC hypoxia leads to increased Cldn4, in both nerve injury and diabetic ED rat models, and promotes fibrosis by activating the JNK signaling pathway.


Subject(s)
Erectile Dysfunction , Fibrosis , MAP Kinase Signaling System , Penis , Male , Animals , Penis/pathology , Erectile Dysfunction/genetics , Erectile Dysfunction/etiology , Rats , MAP Kinase Signaling System/genetics , MAP Kinase Signaling System/physiology , Rats, Sprague-Dawley , Myocytes, Smooth Muscle/metabolism , Disease Models, Animal , Penile Erection/physiology , Claudins/genetics , Claudins/metabolism
2.
Chinese Journal of Orthopaedics ; (12): 105-113, 2024.
Article in Chinese | WPRIM (Western Pacific) | ID: wpr-1027695

ABSTRACT

Objective:To explore the optimal index of rotational displacement of femoral neck fractures by modeling the axial rotational displacement of femoral neck fractures after reduction and based on X-ray projections.Methods:Six dry human femur specimens, comprising 2 males and 4 females, were utilized in the study. Design and manufacture a proximal femur ortholateral and oblique X-ray casting jigs and mounts. The femoral neck fracture was modeled on the femoral specimen, with Pauwells 30°, 50°, and 70° models (2 each) made according to Pauwells typing. The fractures were manually repositioned with residual anterior 20°, 40° and 60° axial rotational displacements. Each fracture model was projected at different angles (pedicled 40°, pedicled 20°, vertical 0°, cephalad 20°, and cephalad 40°), and the trabecular angle and Garden's alignment index of the model were measured to observe the imaging characteristics of the fracture line on the medial oblique and lateral oblique radiographs.Results:In the presence of a 20° and 40° anterior rotational displacement following reduction of a femoral neck fracture, the trabecular angle in the rotationally displaced group was not significantly different from that of the anatomically repositioned group in various projection positions. However, when a residual rotational displacement of 60° was present, the trabeculae appeared blurred at most projection angles in the Pauwells 30° and 50° models, failing to measure trabecular angles. In the Pauwells 70° fracture model, the trabecular angle in the rotational displacement group was significantly different from that in the anatomical reduction group. In anteroposterior radiographs, when the anterior rotation displacement was 60° in the Pauwells 70° group, Garden's contralateral index showed an unsatisfactory restoration (150°, 142°), whereas all rotationally displaced models in the Pauwells 30° and Pauwells 50° groups had a Garden's contralateral index of >155°, which achieved an acceptable restoration. In lateral radiographs, all rotational displacement models with Garden's alignment index>180° failed to achieve acceptable repositioning, and the larger the Pauwells angle the greater the Garden's alignment index at the same rotational displacement. In the internal oblique position with a bias towards the foot side, the image showed partial overlap between the femoral head and the shaft, making it difficult to assess the quality of the reduction. Conversely, when projected cephalad, the femoral neck appeared longer, particularly at a projection angle of 40° cephalad, allowing for clear observation of the fracture line and the anatomy of the proximal femur. The trabeculae were not well visualized in the external oblique position.Conclusion:There are limitations in applying the trabecular angle to assess the axial rotational displacement of the femoral head after reduction of femoral neck fractures. The Pauwells 70° with residual rotational anterior displacement of 60° was the only way to detect axial rotational displacement of the femoral head on anteroposterior radiographs Garden's alignment index. For the determination of axial rotational displacement of the femoral head, the Garden's alignment index on lateral radiographs provides higher reliability.

3.
Chinese Journal of Geriatrics ; (12): 82-85, 2024.
Article in Chinese | WPRIM (Western Pacific) | ID: wpr-1028251

ABSTRACT

Examining mechanisms involved in the mutual regulation between the muscular system and the skeletal system, elucidating the key issues responsible for loss of muscle and bone mass and strength, and thus halting the progression of these conditions are critical measures for reducing fractures caused by falls and subsequent disability and mortality.At present, most studies have treated the muscular system and the skeletal system separately, often ignoring the mutual regulation and connections between them.This article reviews the current research progress on the mechanisms of interaction between the two systems, aiming to provide a basis for the prevention, diagnosis and treatment of disuse-related diseases in the elderly population.

4.
Article in Chinese | WPRIM (Western Pacific) | ID: wpr-981545

ABSTRACT

In clinical practice, radiopharmaceutical dynamic imaging technology requires the bolus injection method to complete injection. Due to the failure rate and radiation damage of manual injection, even experienced technicians still bear a lot of psychological burden. This study combined the advantages and disadvantages of various manual injection modes to develop the radiopharmaceutical bolus injector, and explored the application of automatic injection in the field of bolus injection from four aspects: radiation protection, occlusion response, sterility of injection process and effect of bolus injection. Compared with the current mainstream manual injection method, the bolus manufactured by the radiopharmaceutical bolus injector based on the automatic hemostasis method had a narrower full width at half maximum and better repeatability. At the same time, radiopharmaceutical bolus injector had reduced the radiation dose of the technician's palm by 98.8%, and ensured more efficient vein occlusion recognition performance and sterility of the entire injection process. The radiopharmaceutical bolus injector based on automatic hemostasis has application potential in improving the effect and repeatability of bolus injection.


Subject(s)
Radiopharmaceuticals , Injections , Hand
5.
Chinese Journal of Trauma ; (12): 1139-1146, 2023.
Article in Chinese | WPRIM (Western Pacific) | ID: wpr-1026998

ABSTRACT

Femoral fracture is a common type of fracture in clinical practice, and poor fracture reduction may lead to malunion and dysfunction. At present, traditional reduction with manipulation and intramedullary nailing are the mainstream treatments, but there exist problems such as X-ray exposure or poor reduction. Fracture reduction robots are of positive significance in improving the safety of surgical treatment of femur fracture, avoiding repetitive operations and poor alignment, and shortening the patients′ postoperative recovery time. Navigation algorithm is the key to achieve the function of femoral repositioning. Understanding the advantages and disadvantages that various types of navigation algorithms demonstrated in femoral reduction applications is important for giving full play to the value of fracture reduction robots in femoral reduction. Therefore, the authors reviewed the research progress in existing robot navigation algorithms applied in femoral fracture repositioning from the following four aspects, including image alignment algorithm, algorithm for establishing the target pose of femoral repositioning, algorithm for compensating the mechanical error, and algorithm for path planning, hoping to provide a reference for the application and research of navigation algorithms of fracture reduction robots.

6.
Chinese Journal of Trauma ; (12): 1147-1152, 2023.
Article in Chinese | WPRIM (Western Pacific) | ID: wpr-1026999

ABSTRACT

Bone defects, often accompanied by osteomyelitis, soft tissue contusions, etc, are facing lengthy treatment process and slow healing, seriously jeopardizing the structural integrity of the human bone tissue. Currently, the main treatment for bone defects involves autologous or allogeneic bone transplant. However, autologous bone transplant poses problems, including long surgical duration, increased pain and complications such as infections. Additionally, immune rejection reactions also limit the effectiveness of allogeneic bone transplant of the same species. Bone scaffolds have become a potential alternative for bone transplant, but problems such as sharp edges of the scaffolds and poor compatibility with human tissues exist. Triply periodic minimal surface (TPMS), with an average curvature of zero has lower levels of stress concentration and the ability to be precisely expressed with mathematical formulas, compared with other structures. Its application in bone scaffolds attracts much attention, but there is currently a lack of comprehensive understanding of the impacts of different types of TPMS on the performance of bone scaffolds. With this purpose, the authors reviewed the research progress in the impacts of different types of TPMS on the performance of bone scaffolds, providing a reference for the construction of bone scaffolds.

7.
Chinese Journal of Geriatrics ; (12): 1320-1325, 2023.
Article in Chinese | WPRIM (Western Pacific) | ID: wpr-1028206

ABSTRACT

Objective:To compare the clinical results and costs of treatment between internal fixation and total hip replacement in patients aged 60 to 75 years with femoral neck fractures, in order to provide a reference basis for choosing the appropriate surgical procedure for patients in this age group.Methods:According to the inclusion and exclusion criteria, we selected 69 patients treated with internal fixation and 88 patients treated with total hip replacement for femoral neck fractures, and collected relevant data to analyze the differences in clinical characteristics and prognosis between the two groups.Results:The total hip replacement group was older than the internal fixation group[68(64, 72) vs.63(61, 68), Z=-4.536, P<0.001]. There were 20 men(29.0%)and 49 women(71.0%)in the internal fixation group, and 13 men(14.8%)and 75 women(85.2%)in the total hip replacement group.Both groups had more women than men( χ2=4.706, P=0.030). The ratio of the displaced type to the non-displaced type was higher in the total hip replacement group than in the internal fixation group(90.9% vs.46.4%, χ2=37.510, P<0.001). Postoperative serum albumin levels were lower than preoperative levels in both groups, with greater decreases in the total hip replacement group than in the internal fixation group[(9.06±3.45)g/L vs.(7.07±3.37)g/L, t=-3.393, P=0.001]. The total hip replacement group had a higher intraoperative bleeding volume and blood transfusion volume than the internal fixation group( P<0.05), and the days of hospitalization[12(9, 14)d]and hospitalization costs[¥89222.1(84826.8, 93040.0)]were higher than those in the internal fixation group[9(8, 10)d; ¥51158.9(47816.5, 54098.4), Z=-5.138, -10.737, P<0.001 for both]. Weight-bearing after total hip replacement occurred earlier than the internal fixation group[32.0(28.0, 36.5)d vs.92.0(89.3, 95.5)d, Z=-10.228, P<0.001]. There were no significant differences between the two types of surgery for non-displaced femoral neck fractures at 1 year after surgery in the Harris hip score and the quality of life score EQ-5D.For patients with displacement, the rates of excellent and good outcomes based on the Harris score for the total hip replacement group were significantly higher than those for the internal fixation group at 1 year after surgery(97.5% vs.81.3%, χ2=6.697, P=0.010); the postoperative quality of life score EQ-5D was also better than that of the internal fixation group[0.9(0.7, 1.0) vs.1.0(1.0, 1.0), Z=-4.785, P<0.001], and the incidence of postoperative pain and anxiety was lower than that in the internal fixation group(6.3% vs.28.1%, 1.3%, vs.50.0%, χ2=7.928, 38.032, all P<0.01). Conclusions:The mortality and short-term postoperative complications between internal fixation and total hip replacement have no significant differences.There is no significant difference in postoperative function between the two surgical methods for patients with non-displaced femoral neck fractures.For patients with displacement, total hip arthroplasty is superior to internal fixation.The cost of initial hospitalization for internal fixation is significantly lower than for total hip replacement.

8.
Article in Chinese | WPRIM (Western Pacific) | ID: wpr-1009061

ABSTRACT

OBJECTIVE@#To summarize the influence of microstructure on performance of triply-periodic minimal surface (TPMS) bone scaffolds.@*METHODS@#The relevant literature on the microstructure of TPMS bone scaffolds both domestically and internationally in recent years was widely reviewed, and the research progress in the imfluence of microstructure on the performance of bone scaffolds was summarized.@*RESULTS@#The microstructure characteristics of TPMS bone scaffolds, such as pore shape, porosity, pore size, curvature, specific surface area, and tortuosity, exert a profound influence on bone scaffold performance. By finely adjusting the above parameters, it becomes feasible to substantially optimize the structural mechanical characteristics of the scaffold, thereby effectively preempting the occurrence of stress shielding phenomena. Concurrently, the manipulation of these parameters can also optimize the scaffold's biological performance, facilitating cell adhesion, proliferation, and growth, while facilitating the ingrowth and permeation of bone tissue. Ultimately, the ideal bone fusion results will obtain.@*CONCLUSION@#The microstructure significantly and substantially influences the performance of TPMS bone scaffolds. By deeply exploring the characteristics of these microstructure effects on the performance of bone scaffolds, the design of bone scaffolds can be further optimized to better match specific implantation regions.


Subject(s)
Tissue Scaffolds/chemistry , Tissue Engineering/methods , Bone and Bones , Porosity
9.
Journal of Medical Biomechanics ; (6): E084-E089, 2023.
Article in Chinese | WPRIM (Western Pacific) | ID: wpr-987918

ABSTRACT

Objective To analyze the influence from material and size of the filling block on stress distributions of the tibial osteotomy model. Methods The filling blocks with three different materials (iliac bone, cancellous bone and polyetheretherketone (PEEK)) and five different sizes were established and implanted to the tibial osteotomy models, respectively. The mechanical loads were applied on the model, the stress distribution and edge displacement of the model were analyzed. Results For three kinds of materials, the stress at proximal end of the tibia and the plate, as well as edge displacement in the model implanted with filling block by iliac bone material were lower than those of the cancellous bone and PEEK, but the filling block by iliac bone material had the highest stress. When the filling blocks with different sizes were implanted in osteotomy space, the stress distribution on each part of the tibial osteotomy and edge displacement were different. Especially when the width of the filling block was reduced from 30 mm to 10 mm, the peak stress of the proximal tibia, steel plate and filling block was increased by 49. 3% , 92. 7% and 54. 4% on average. Conclusions Different filling block parameters will affect the stress distribution in different parts of the tibial osteotomy. The research results provide the theoretical basis for parameter selection of the tibial osteotomy filling block in clinic.

10.
Journal of Medical Biomechanics ; (6): E561-E567, 2023.
Article in Chinese | WPRIM (Western Pacific) | ID: wpr-987986

ABSTRACT

Objective To compare the differences in kinematic parameters and plantar pressures for two types of knee varus with tibial and femoral origins in gait analysis, so as to provide biomechanical theoretical basis for different types of genu varus. Methods Twenty-six patients with unilateral knee osteoarthritis (KOA) varus genu were enrolled, with 13 from femoral and 13 from tibial sources. Using Noraxon MyoMotion three-dimensional (3D) motion capture system and Footscan plantar pressure test system, the gait of the subjects during natural walking was measured, the temporal and spatial parameters of the gait, the kinematics parameters of lower limb joints and plantar pressures were collected, to make comparative analysis between the two groups. Results The range of knee flexion and extension of tibial varus, the peak of hip abduction, the range of motion (ROM) of hip adduction and abduction and the peak of ankle pronation were larger than those of femoral lateral genu varus. The peak of knee flexion and hip adduction was smaller than that of femoral lateral genu varus. Compared with femoral varus, subjects with tibial varus had increased stress time and peak pressure on the plantar of the 4th and 5th metatarsals (P<0.05). In the 3rd metatarsal region, the impulse of healthy femoral limb was greater than that of healthy limb with tibial deformity. While in the medial calcaneal region, the impulse of healthy femoral limb was smaller (P<0.05). Conclusions There are some differences in kinematic parameters and plantar pressures between two different types of unilateral genu varus patients. The results of this study are helpful to understand the abnormal gait caused by genu varus, and provide reliable reference for postoperative rehabilitation and limb exercise for different types of genu varus.

11.
Article in Chinese | WPRIM (Western Pacific) | ID: wpr-992686

ABSTRACT

Orthopedic robots, as intelligent medical devices, have achieved good outcomes in clinical application in some orthopedic surgeries. Artificial intelligence (AI) has played an important role in the development of orthopedic robots due to its powerful capabilities of information processing and decision-making. The developing trends of orthopedic robotics are automation and intelligentization. Since AI has demonstrated great advantages in preoperative planning, an increasing number of researchers have been devoted to AI application in intraoperative navigation by an orthopedic robot. This paper outlines the exploratory efforts in applying AI technology to the intraoperative navigation assisted by an orthopedic robot, describes the advantages of AI in improving accuracy and reducing radiation, and forecasts research prospects in application of AI technology to orthopedic robots based on the current situation.

12.
Chinese Journal of Orthopaedics ; (12): 122-130, 2023.
Article in Chinese | WPRIM (Western Pacific) | ID: wpr-993418

ABSTRACT

Objective:To establish a risk assessment system focusing on surgical and anesthesian-related indicators for the incidence of complications and mortality of hip fracture surgery in senile patients, and to evaluate its prediction accuracy, sensitivity and specificity.Methods:From January 2020 to February 2021, a total of 1 086 elderly patients (493 males and 593 females) aged 76±5 years (ranging from 60 to 94 years) underwent hip fracture surgery in Tianjin Hospital were collected. A total of 543 patients were randomly selected for the establishment of the hip fracture scoring system in senile patients, including 253 males and 290 females, aged 75±6 years (ranging from 60 to 92 years). With the preoperative physiological factor score and surgical risk factor score as independent variables and the occurrence of complications and death as dependent variables, binary logistic regression analysis was performed to establish a surgical risk scoring system for hip fracture in senile patients. The remaining 543 patients, including 240 males and 303 females, aged 74±7 years (range 60-94 years), their data were used to compare AUC, sensitivity, specificity, and compliance of the physiological and operative severity score for the enumeration of mortality and morbidity (POSSUM), Daping orthopedics operative risk scoring system for senile patient (DORSSSP), and our surgical risk scoring system for hip fracture in senile patients through receiver operating characteristic (ROC) curves, and to compare the predictive value of these systems for complication incidence and mortality.Results:The predictive model equation of the elderly hip fracture scoring system is: ln R1/ (1- R1) =-7.13+0.112× PS+0.148× OS; ln R2/ (1- R2) =-6.14+0.124× PS+0.136× OS; [ R1 is the incidence of complications, R2 is the mortality, PS (physiology score) is the score of preoperative physiological factors, and OS (operation score) is the score of surgical risk factors]. Among the 543 patients whose data were used to compared with the hip fracture scoring system, POSSUM and DORSSSP, 72 actually developed complications and 36 died. The complication rate predicted by surgical risk scoring system for hip fracture in senile patients was 12.05%±6.34% (range 6.18%-61.29%), and 64 cases were predicted to have complications. The predicted mortality was 6.05%±3.26% (range 2.45%-58.36%), and 29 cases were predicted to die. The complication rate predicted by POSSUM was 25.36%±13.95% (range 9.16%-76.34%), and 126 cases were predicted to have complications. The predicted mortality rate was 10.46%±5.31% (range 6.23%-59.34%), and 54 deaths were predicted. The predicted complication rate of DORSSSP was 19.34%±9.67% (range 8.36%-70.85%), and 99 cases were predicted to have complications. The predicted mortality was 10.12%±5.16% (range 7.35%-57.54%), and 52 deaths were predicted. In predicting the incidence of complications, the AUC of surgical risk scoring system for hip fracture in senile patients, POSSUM and DORSSSP were 0.95, 0.82 and 0.75, the sensitivity was 0.89, 0.83 and 0.85, the specificity was 0.80, 0.86 and 0.92, and the compliance rate was 0.94, 0.93 and 0.94, respectively. In the prediction of mortality, the AUC of surgical risk scoring system for hip fracture in senile patients, POSSUM and DORSSSP were 0.87, 0.67 and 0.71, the sensitivity was 0.85, 0.69 and 0.75, the specificity was 0.73, 0.94, 0.95, and the compliance rate was 0.94, 0.93 and 0.94, respectively. Conclusion:Compared with POSSUM and DORSSSP, hip fracture scoring system in elderly patients has improved its ability to predict surgical risk, and can accurately predict the incidence of complications and mortality in elderly patients undergoing hip surgery.

13.
Chinese Journal of Orthopaedics ; (12): 915-921, 2023.
Article in Chinese | WPRIM (Western Pacific) | ID: wpr-993521

ABSTRACT

The sources of common knee valgus deformities were classified in order to better plan the orthopedic methods, matching prostheses and soft tissue repair of knee valgus deformities.Based on the analysis of typical clinical cases and the operability of classification standards in practical clinical practice, it is of great significance to establish a reasonable morphological classification of knee valgus deformity, in order to grasp the characteristics and patterns of the onset of valgus deformity. According to the origin of the deformity and the tension of the medial and lateral collateral ligaments, the classification of the genu valgus deformity can be divided into the classification of the traditional Genu valgum deformity origin and the classification of the new Genu valgum deformity origin. Although both of them highlight the skeletal characteristics and soft tissue conditions of the valgus deformity, they are quite different. Traditional classification is based on femoral tibial angle, valgus angle, etc; The new classification is divided into mechanical angle, anatomical angle, distal condylar angle, etc. The origin of Genu valgum deformity is generally complex. The traditional classification cannot fully reflect the origin of valgus deformity and the tension state of soft tissue. The new classification, especially based on the classification of anatomical angle valgus deformity, can not only reflect the morphological and anatomical details of knee valgus deformity, but also reflect the tension state of the medial and lateral collateral ligaments and local soft tissue stress state that determine the stability of the knee joint. At present, the commonly used surgical methods for valgus deformity of the knee include periarticular osteotomy of the knee and total knee Joint replacement. The former focuses on correcting extraarticular deformity without over repairing ligaments, and the latter focuses on force line correction, which is the final treatment for terminal valgus deformity. The application of digital technology in clinical orthopedics can improve the accuracy of implant placement. Implant placement needs to be based on the patient's bone characteristics and degree of deformity. For patients with severe deformity, the application of digital technology can improve the accuracy of implant placement and assist in the treatment of knee valgus deformity.

14.
Article in Chinese | WPRIM (Western Pacific) | ID: wpr-1008924

ABSTRACT

Radiopharmaceutical dynamic imaging typically necessitates intravenous injection via the bolus method. However, manual bolus injection carries the risk of handling errors as well as radiological injuries. Hence, there is potential for automated injection devices to replace manual injection methods. In this study, the effect of micro-bolus pulse injection technology was compared and verified by radioactive experiments using a programmable injection pump, and the overall bubble recognition experiment and rat tail vein simulation injection verification were performed using the piezoelectric sensor preloading method. The results showed that at the same injection peak speed, the effective flushing volume of micro-bolus pulse flushing (about 83 μL/pulse) was 49.65% lower than that of uniform injection and 25.77% lower than that of manual flushing. In order to avoid the dilution effect of long pipe on the volume of liquid, the use of piezoelectric sensor for sealing preloading detection could accurately predict the bubbles of more than 100 μL in the syringe. In the simulated injection experiment of rat tail vein, when the needle was placed in different tissues by preloading 100 μL normal saline, the piezoelectric sensor fed back a large difference in pressure attenuation rate within one second, which was 2.78% in muscle, 17.28% in subcutaneous and 54.71% in vein. Micro-bolus pulse injection method and piezoelectric sensor sealing preloading method have application potential in improving the safety of radiopharmaceutical automatic bolus injection.


Subject(s)
Animals , Rats , Radiopharmaceuticals/administration & dosage
15.
Article in Chinese | WPRIM (Western Pacific) | ID: wpr-1009020

ABSTRACT

OBJECTIVE@#To review the research progress of design of bone scaffolds with different single cell structures.@*METHODS@#The related literature on the study of bone scaffolds with different single cell structures at home and abroad in recent years was extensively reviewed, and the research progress was summarized.@*RESULTS@#The single cell structure of bone scaffold can be divided into regular cell structure, irregular cell structure, cell structure designed based on topology optimization theory, and cell structure designed based on triply periodic minimal surface. Different single cell structures have different structural morphology and geometric characteristics, and the selection of single cell structure directly determines the mechanical properties and biological properties of bone scaffold. It is very important to choose a reasonable cell structure for bone scaffold to replace the original bone tissue.@*CONCLUSION@#Bone scaffolds have been widely studied, but there are many kinds of bone scaffolds at present, and the optimization of single cell structure should be considered comprehensively, which is helpful to develop bone scaffolds with excellent performance and provide effective support for bone tissue.


Subject(s)
Bone and Bones , Tissue Scaffolds
16.
Article in Chinese | WPRIM (Western Pacific) | ID: wpr-1009039

ABSTRACT

OBJECTIVE@#To summarize the progress of research related to the surgical treatment of recurrent patellar dislocation by peripatellar osteotomy in clinical practice, in order to provide reference for clinical treatment.@*METHODS@#The recent literature on peripatellar osteotomy for recurrent patellar dislocation at home and abroad was reviewed, and the bony structural abnormalities, imaging diagnosis, and treatment status were summarized.@*RESULTS@#Abnormalities in the bony anatomy of the lower limb and poor alignment lead to patellofemoral joint instability through the quadriceps pulling force line and play an important role in the pathogenesis of recurrent patellar dislocation. Identifying the source of the deformity and intervening with peripatellar osteotomy to restore the biomechanical structure of the patellofemoral joint can reduce the risk of soft tissue surgical failure, delay joint degeneration, and achieve the target of treatment.@*CONCLUSION@#In the clinical diagnosis and treatment of recurrent patellar dislocation, the factors causing patellofemoral joint instability should be comprehensively evaluated to guide the selection of surgery and personalized treatment.


Subject(s)
Humans , Patellar Dislocation/surgery , Joint Dislocations , Joint Instability/surgery , Lower Extremity , Osteotomy
17.
Chinese Journal of Trauma ; (12): 125-129, 2022.
Article in Chinese | WPRIM (Western Pacific) | ID: wpr-932216

ABSTRACT

Objective:To analyze the morphology and distribution characteristics of subchondral bone cysts of the talus by CT three-dimensional reconstruction.Methods:A total of 176 patients diagnosed with subchondral bone cyst of the talus after CT scan of the ankle or foot from 2015 to 2020 were retrieved from the imaging report database of Tianjin Hospital, including 77 males and 99 females, aged 14-84 years[(56.1±14.0)years]. After three-dimensional reconstruction of the talus and cyst area by Mimics 20.0 software, an equal 2×2 grid configuration was constructed to divide the domed articular surface into four regions: anteromedial, anterolateral, posteromedial and posterolateral. For subchondral cyst of the talus, area involved under grid localization, gender, age and side of the onset were recorded. The anteroposterior diameter, transverse diameter, depth, surface area and volume of the subchondral bone cyst of the talus were measured.Results:Subchondral cyst of the talus was anteromedial in 131 patients (74.4%), anterolateral in 5(2.8%), posteromedial in 34(19.3%), and posterolateral in 6(3.4%). Subchondral cyst of the talus occurred in the older aged (≥60 years) for 78 patients (44.3%), in the middle aged (45-59 years) for 62(35.2%), in young adults for 32(18.2%), and in preadolescents for 4(2.3%). The age composition of the subchondral cyst of the talus involving the anteromedial, anterolateral, posteromedial and posterolateral regions was 59(49, 64)years, 44(39, 45)years, 61(54, 68)years and 40(22, 58) years, respectively (all P<0.01). There were no statistically significant differences in gender and side of the onset (all P>0.05). The anteroposterior diameter of the subchondral bone cysts located anteromedially, anterolaterally, posteromedially and posterolaterally was (9.7±4.4)mm, (3.5±1.1)mm, (10.3±4.4)mm and (2.1±0.8)mm, respectively; the transverse diameter was (5.4±1.7)mm, (3.9±1.8)mm, (5.9±2.2)mm and (3.4±1.1)mm, respectively; the depth was (7.1±2.4)mm, (3.2±2.2)mm, (8.2±3.0)mm and (3.9±1.9)mm, respectively; the surface area was 156.1(82.6, 198.2)mm 2, 23.0(21.4, 28.9)mm 2, 180.0(75.1, 230.4)mm 2 and 28.0(20.3, 36.7)mm 2, respectively; the volume was 77.1(37.1, 129.1)mm 3, 23.9(14.2, 37.8)mm 3, 104.6(37.7, 157.4)mm 3 and 13.0(10.4, 16.0)mm 3, respectively. When comparing the anteroposterior diameter, transverse diameter, depth, surface area and volume of the subchondral bone cysts in the anteromedial and posteromedial regions with the anterolateral and posterolateral regions, the differences were statistically significant (all P<0.01) except for the transverse diameter of the subchondral bone cysts in the anteromedial region and the anterolateral region ( P>0.05). In addition, the depth of subchondral bone cysts in the anteromedial region was significantly greater than that in the posteromedial region ( P<0.05). Conclusions:Subchondral bone cysts of the talar are commonly found in the middle- and old-aged population. Anteromedial lesions of the talar dome are the most commonly seen, with large and deeply involved cysts, followed by posteromedial lesions of the dome, while anterolateral and posterolateral lesions of the dome are less common and have smaller cyst sizes. An equal 2×2 grid configuration for talar cysts is useful in positioning and characterizing bone cysts, and can assist clinicians in accurately diagnosing and treating bone cysts.

18.
Chinese Journal of Orthopaedics ; (12): 668-674, 2022.
Article in Chinese | WPRIM (Western Pacific) | ID: wpr-932879

ABSTRACT

Osteoclast is a type of multinuclear giant cell, which plays a role in bone resorption in the homeostasis of bone mass. Excessive bone resorption leads to osteoporosis and other diseases characterized by decreased bone mass. Ca 2+ metabolism plays an important role as a second messenger in the differentiation, migration, fusion and bone resorption of osteoclast. The transient receptor potential vanilloid (TRPV) ion channel is expressed in a variety of cells, including osteoclast. Current studies have found that the TRPV ion channel can participate in the production and bone resorption function of osteoclast by increasing intracellular Ca 2+ concentration and calcium oscillations. This article reviews the relationship between the TRPV ion channel and the changes of Ca 2+ concentration and the potential mechanisms involved in osteoclast activity, so as to provide a reference for further research on diseases characterized by abnormally increased activation of osteoclast in the future.

19.
Chinese Journal of Orthopaedics ; (12): 760-767, 2022.
Article in Chinese | WPRIM (Western Pacific) | ID: wpr-957066

ABSTRACT

Objective:To investigate the clinical effects of anterior cage inserting for old thoracolumbar fractures with kyphosis through facet joint approach.Methods:A retrospective analysis was conducted on 32 patients with old thoracolumbar fractures complicated with kyphosis admitted from January 2018 to December 2019, including 14 males and 18 females. The average age was 47.3±13.1 years (range, 26-70 years). Thoracolumbar injury classification (TLICS) scores of patients with initial injury were 3-5 points, with an average of 4.0 points. After 6.3±2.9 months (range, 3-16 months) conservative treatment, intractable thorax and lumbar or back pain still existed. Anterior cage inserting via articular protrusion was performed in 15 cases and posterior screw placement and bone grafting fusion of injured vertebrae was performed in 17 cases. Preoperative sagittal Cobb angle was 27.0°±3.9° and 26.8°±4.6° in the anterior cage inserting group and fixation on fractured vertebrae group ( t=0.07, P=0.946), respectively. Sagittal vertical axis (SVA) was 4.2±1.8 cm and 4.1±2.1 cm ( t=0.14, P=0.887), respectively. The number of patients with ASIA impairment scale (AIS) of the anterior cage inserting group before surgery was 1 in grade C, 4 in grade D and 10 in grade E. However, the number of that in fixation on fractured vertebrae group was 2 in grade C, 2 in grade D and 13 in grade E. There was no significant difference between the two groups (χ 2=1.34, P=0.520). Results:All 32 patients were followed up for 12.2±3.1 months in the anterior cage inserting group and 12.0±3.3 months in fixation on fractured vertebrae group. The operative duration of the anterior cage inserting group and fixation on fractured vertebrae was 128±24.5 min and 123±40.6 min ( t=0.42, P=0.681). The intraoperative blood loss was 485±12.6 ml and 478±16.3 ml ( t=0.13, P=0.894), respectively. At the last follow-up, the improvement rate of VAS score of the anterior cage inserting group was higher than that of fixation on fractured vertebrae group (90%±10% vs. 75%±20%, t=3.17, P=0.004). The height of anterior margin of injured vertebra in the two groups was increased by 1.02±0.10 cm and 0.29±0.14 cm, the change rate of anterior cage inserting group was higher than that of fixation on fractured vertebrae group (67.1%±31.5% vs. 19.0%±14.9%, t=16.29, P<0.001). The sagittal Cobb angle of the anterior cage inserting group was significantly lower than that of fixation on fractured vertebrae group (7.4°±1.5° vs. 11.6°±2.5°, t=-5.85, P<0.001). The SVA of anterior cage inserting group was lower than that of fixation on fractured vertebrae group (1.1±0.6 cm vs. 1.6±0.6 cm, t=2.35, P=0.025). There were 15 patients in AIS grade E in the anterior cage inserting group, while 1 patient in grade D and 16 patients in grade E in fixation on fractured vertebrae group without significant difference between the two groups (χ 2=0.83, P=0.706). Conclusion:The treatment of old thoracolumbar fractures with kyphosis through facet joint approach and anterior fixation could achieve satisfied effects and could relieve pain symptoms of thoracolumbar and back, compared with posterior fusion for injured vertebra with nail and bone grafting.

20.
Chinese Journal of Orthopaedics ; (12): 856-863, 2022.
Article in Chinese | WPRIM (Western Pacific) | ID: wpr-957078

ABSTRACT

Objective:To observe the effects of alendronate (ALN) on the expression of autophagy signaling pathway related proteins LC3, Beclin-1 and P62 in the muscle tissue of mice with denervated skeletal muscle atrophy, and to explore the potential molecular biological mechanism of ALN in the treatment of skeletal muscle atrophy.Methods:Thirty males C57BL/6 mice were divided into three groups with 10 mices in each group by random number method, including blank control group: sciatic nerve exposed without resection, model group: sciatic nerve exposed and resection, ALN group: sciatic nerve resection +ALN intervention. At the intervention stage, mices were given 1 mg/kg ALN by intragastric administration. The weight of gastrocnemius muscle was weighed by wet weight method. Atpase staining was used to distinguish muscle fiber types. HE staining was used to observe the arrangement and cross-sectional area of gastrocnemius muscle fibers in each group, and further quantitative analysis was performed by Image J 1.48 software. Western blotting and immunohistochemical staining were performed to detect the expressions of MHC and MuRF1 as well as LC3, Beclin-1 and P62 in gastrocnemius tissues of each group.Results:The weight of gastrocnemius muscle in the model group 137±7.80 mg was significantly lower than that in the blank control group 203±10.34 mg, which proved that the denervation muscle atrophy mouse model was successfully established. After intervention, the gastrocnemius muscle weight of ALN group 177±11.65 mg was significantly higher than that of model group, and the muscle mass was significantly improved. HE staining showed that muscle fibers in the model group were loosely arranged and the cross-sectional area was significantly smaller than that in the blank control group, and there were more blue stains among muscle fibers. Atpase staining showed that the distribution of type II muscle fibers in the model group was increased compared with that in the blank control group, and the distribution of type II muscle fibers in the ALN group was decreased compared with that in the model group, but higher than that in the blank control group. The results showed that the most widely distributed muscle fiber cross-sectional area was 600-800μm 2 in the blank control group, 200-400 μm 2 in the model group, and 400-600 μm 2 in the ALN group. The results of quantitative calculation of muscle fiber cross-sectional area by Image J 1.48 showed that the mean value of muscle fiber cross-sectional area in the model group was (352±18) μm 2, which was significantly reduced compared with the blank control group 794±20 μm 2. After ALN treatment, muscle fiber cross-sectional area recovered somewhat. The mean muscle fiber cross-sectional area of ALN group was 578±23 μm 2, which increased muscle fiber cross-sectional area by 29%. Western blotting results showed that the expressions of MHC, LC3 and Beclin-1 in model group were significantly lower than those in blank control group ( P<0.05), while MuRF1 and P62 proteins were significantly higher than those in blank control group ( P<0.05). The MHC, LC3 and Beclin-1 proteins in ALN group were significantly higher than those in model group (0.12±0.01 vs. 0.10±0.003, 0.15±0.02 vs. 0.10±0.02, 0.13±0.03 vs. 0.09±0.04). MuRF1 and P62 proteins in ALN group were significantly lower than those in model group (0.10±0.004 vs. 0.15±0.01, 0.16±0.03 vs. 0.20±0.03). MHC immunohistochemical staining showed that the expression of MHC in gastrocnemius of mice in model group was significantly lower than that in blank control group, and the expression of MHC in gastrocnemius of mice in ALN group was higher than that in model group ( P<0.05). Conclusion:ALN has a therapeutic effect on skeletal muscle atrophy, and its mechanism may be realized by moderately activating the LC3/Beclin-1 autophagy signaling pathway.

SELECTION OF CITATIONS
SEARCH DETAIL