Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 2 de 2
Filter
Add more filters











Language
Publication year range
1.
Article in Chinese | WPRIM (Western Pacific) | ID: wpr-1027518

ABSTRACT

Objective:To evaluate the technical approach and application value of DynaCT biliary reconstruction with CT images fusion (DynaCT-CT fusion) for the treatment of complex hepatolithiasis.Methods:The data of 18 patients with complex hepatolithiasis admitted to the First Affiliated Hospital of Guangzhou Medical University from May 2022 to October 2022 were retrospectively analyzed, including 7 males and 11 females, aged (50.6±15.0) years. Preoperative DynaCT biliary reconstruction with CT images fusion was performed to guide the percutaneous transhepatic one-step biliary fistulation (PTOBF). The technical data, including the bile duct with stones identified by preoperative imaging, the actual bile duct with stones confirmed intraoperatively, the satisfied stone removal time for each targeted bile duct, the actual stone removal time for each targeted bile duct, the intraoperative identification of CT-negative stones, the postoperative complications and reoperation were analyzed.Results:In 18 patients, a total of 95 target bile ducts with stones were identified by preoperative DynaCT-CT fusion technology, involving the first, secondary and tertiary bile ducts. Preoperative CT identified 29 lesions of stones involving the first and secondary bile ducts. CT negative stones were confirmed in 5 patients by DynaCT-CT fusion. Bile duct stricture occurred in 12 patients. All procedures were completed without postoperative bile leakage or hemorrhage. A total of 82 lesions of stones were successfully removed with a removal time of (25.9±12.8) min. The satisfied stone removal time for each targeted bile duct was (10.1±7.6) min, and the actual stone removal time was (10.5±7.4) min. Immediate stone clearance was achieved in 13 patients. Biliary tract infection occurred in 2 patients, and 5 patients underwent reoperation for residual or recurrent stones.Conclusion:The DynaCT-CT fusion technology guided PTOBF is feasible and safe in patients with complex hepatolithiasis. It could effectively detect more stones, shorten the stone clearance time. DynaCT-CT fusion technology provides a new strategy for the treatment of hepatolithiasis.

2.
Article in Chinese | WPRIM (Western Pacific) | ID: wpr-884777

ABSTRACT

Objective:To investigate the correlations between perfused lung volumes, visual scores (using perfusion SPECT/CT) and right-heart catheter (RHC) hemodynamic parameters in patients with chronic thromboembolic pulmonary hypertension (CTEPH).Methods:A total of 51 consecutive CTEPH patients (17 males, 34 females, age (59±12) years) in the First Affiliated Hospital of Guangzhou Medical University between March 2015 and July 2019 were retrospectively analyzed. All patients underwent lung perfusion SPECT/CT imaging and RHC examinations. Perfused lung volumes were determined using threshold-based (15%-85%) segmentation. Visual semiquantitative scoring in each lung segment was performed using Begic method. RHC hemodynamic parameters including pulmonary artery systolic pressure (PASP), pulmonary arterial diastolic pressure (PADP), mean pulmonary artery pressure (mPAP), pulmonary arteriolar wedge pressure (PAWP), pulmonary vessel resistance (PVR), cardiac output (CO), cardiac index (CI) were recorded. Spearman correlation analysis was used to evaluate the correlations between perfused lung volumes, visual scores and hemodynamic parameters.Results:There were significant correlations between perfused lung volumes (30%-70% threshold) and mPAP ( rs values: from -0.414 to -0.302, all P<0.05). Among them, perfused lung volumes under the threshold of 40% and 45% were moderately correlated with mPAP ( rs values: -0.414, -0.412, both P<0.05). Perfused lung volume (40% threshold) was moderately negatively correlated with PASP, PADP ( rs values: -0.402, -0.440, both P<0.05), and slightly negatively correlated with PVR ( rs=-0.352, P<0.05). Visual scores were slightly positively correlated with the PADP ( rs=0.311, P<0.05), while there was no correlation between visual scores and other RHC hemodynamic parameters ( rs values: from -0.201 to 0.275, all P>0.05). Conclusion:Perfused lung volumes based on threshold-based segmentation in lung perfusion SPECT/CT imaging can accurately reflect hemodynamic status and may provide useful information for severity assessment of CTEPH.

SELECTION OF CITATIONS
SEARCH DETAIL