Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 143
Filter
2.
J Invasive Cardiol ; 2024 May 20.
Article in English | MEDLINE | ID: mdl-38776474

ABSTRACT

An 87-year-old man with a history of heart failure and a modified bio-Bentall Mitroflow 23-mm bioprosthesis (Sorin) was referred to our institution for critical aortic stenosis, which was confirmed by transesophageal echocardiography. Pre-procedural computed tomography revealed slightly calcified bioprosthesis leaflets, adequate coronary ostia height, and a slightly angled Bentall tube graft measuring 29 mm in diameter at the aortic anastomosis .

3.
J Clin Med ; 13(10)2024 May 09.
Article in English | MEDLINE | ID: mdl-38792321

ABSTRACT

Background: The usefulness of drug-eluting balloons (DEBs) has not been fully elucidated in calcified coronary lesions (CCLs). This meta-analysis aimed to evaluate the efficacy of DEBs compared to a drug-eluting stent (DES) in this setting. Methods: PubMed, EMBASE and Cochrane were searched through December 2023. The primary endpoint was 12 months major adverse cardiac events (MACE). Secondary endpoints included clinical outcomes and angiographic results after PCI and at a 12-month follow-up. Results: Five studies and a total of 1141 patients with 1176 coronary lesions were included. Overall, the DEB was comparable to DES in MACE (RR = 0.86, 95% CI: 0.62-1.19, p = 0.36), cardiac death (RR = 0.59, 95% CI: 0.23-1.53, p = 0.28), myocardial infarction (RR = 0.89, 95% CI: 0.25-3.24, p = 0.87) and target lesion revascularization (RR = 1.1, 95% CI: 0.68-1.77, p = 0.70). Although the DEB was associated with worse acute angiographic outcomes (acute gain; MD = -0.65, 95% CI: -0.73, -0.56 and minimal lumen diameter; MD = -0.75, 95% CI: -0.89, -0.61), it showed better results at 12 months follow-up (late lumen loss; MD = -0.34, 95% CI: -0.62, -0.07). Conclusions: This meta-analysis showed that the DEB strategy is comparable to DES in the treatment of CCLs in terms of clinical outcomes. Although the DEB strategy had inferior acute angiographic results, it may offer better angiographic results at follow-up.

4.
Catheter Cardiovasc Interv ; 103(6): 1015-1022, 2024 May.
Article in English | MEDLINE | ID: mdl-38577931

ABSTRACT

BACKGROUND: Previous studies have documented a high rate of implantation success with the ACURATE neo2 valve, as well as a reduction in paravalvular leak (PVL) compared to its predecessor, the ACURATE neo. However, there are no studies that have reviewed and compared the long-term clinical and hemodynamic outcomes of these patients. AIMS: This study aimed to evaluate the results of the ACURATE neo transcatheter aortic valve in a real-world context, and to compare the results of the outcomes of both generations of this device (ACURATE neo and ACURATE neo2), with a specific focus on procedural success, safety, and long-term effectiveness. METHODS: A prospective study including all consecutive patients treated with the ACURATE neo device in seven hospitals was conducted (Clinical Trials Identification Number: NCT03846557). The primary endpoint consisted of a composite of adverse events, including mortality, aortic insufficiency, and other procedural complications. As the second-generation device (ACURATE neo2) replaced the ACURATE neo during the study period, hemodynamic and clinical results before admission, at 30 days, and at 1 year of follow-up were compared between the two generations. RESULTS: A total of 296 patients underwent transcatheter aortic valve implantation with the ACURATE device, with 178 patients receiving the ACURATE neo and 118 patients receiving the ACURATE neo2. In the overall population, the absence of device success occurred in 14.5%. The primary reason for the absence of device success was the presence of para-valvular regurgitation ≥ 2. There were no instances of coronary occlusions, valve embolization, annulus rupture, or procedural deaths. ACURATE neo2 was associated with a significantly higher device success rate (91.7% vs. 82%, p = 0.04), primarily due to a significantly lower rate of para-valvular regurgitation, which remained significant at 1 year. CONCLUSION: The use of ACURATE neo and neo2 transcatheter aortic valves is associated with satisfactory clinical results and an extremely low rate of complications. The ACURATE neo2 enables a significantly higher device success rate, primarily attributed to a significant reduction in the rate of PVL.


Subject(s)
Aortic Valve Stenosis , Aortic Valve , Heart Valve Prosthesis , Hemodynamics , Prosthesis Design , Registries , Transcatheter Aortic Valve Replacement , Aged , Aged, 80 and over , Female , Humans , Male , Aortic Valve/surgery , Aortic Valve/physiopathology , Aortic Valve/diagnostic imaging , Aortic Valve Insufficiency/physiopathology , Aortic Valve Insufficiency/etiology , Aortic Valve Insufficiency/diagnostic imaging , Aortic Valve Stenosis/surgery , Aortic Valve Stenosis/physiopathology , Aortic Valve Stenosis/diagnostic imaging , Postoperative Complications , Prospective Studies , Recovery of Function , Risk Factors , Spain , Time Factors , Transcatheter Aortic Valve Replacement/instrumentation , Transcatheter Aortic Valve Replacement/adverse effects , Treatment Outcome
5.
J Invasive Cardiol ; 2024 Mar 22.
Article in English | MEDLINE | ID: mdl-38517884

ABSTRACT

Dynamic road-mapping (DRM) (Dynamic Coronary Roadmap; Philips) offers a real-time, dynamic overlay of the coronary tree on fluoroscopy.

6.
J Invasive Cardiol ; 2024 Mar 22.
Article in English | MEDLINE | ID: mdl-38517883

ABSTRACT

A 69-year-old man who underwent a liver transplant in 2014 due to hepatitis C virus hepatopathy was evaluated for dyspnea on exertion and chest pain.

7.
J Endovasc Ther ; : 15266028241233994, 2024 Feb 22.
Article in English | MEDLINE | ID: mdl-38385241

ABSTRACT

CLINICAL IMPACT: Mechanical thrombectomy using a thromboaspiration catheter can be an effective alternative in the treatment of subacute pulmonary embolism.

8.
RMD Open ; 10(1)2024 Jan 08.
Article in English | MEDLINE | ID: mdl-38191213

ABSTRACT

BACKGROUND: Systemic lupus erythematosus (SLE) significantly affects the lungs and heart, and pulmonary hypertension (PH) is a severe manifestation that leads to considerable morbidity and mortality. OBJECTIVES: We aimed to determine the prevalence and risk factors of probable SLE-PH, assess the main echocardiographic predictors and develop a potential screening strategy. METHODS: A prospective single-centre study was conducted on 201 patients with SLE who underwent transthoracic echocardiography. Patients meeting PH criteria were referred for right heart catheterisation (RHC). RESULTS: Among patients, 88.56% were women, 85.57% were of Spanish origin and 43.78% had structural heart disease. Out of these, 16 (7.96%) had intermediate or high probability criteria for PH according to European Society of Cardiology (ESC) 2022. Six RHCs confirmed PH with a prevalence of 2.99% for SLE-PH and 1.99% for SLE-pulmonary arterial hypertension (PAH). KEY RISK FACTORS: Key risk factors included age, cardiorespiratory symptoms, serositis, anti-Ro, cardiac biomarkers and altered pulmonary function tests (PFTs). PH was linked to a higher Systemic Lupus International Collaborative Clinics/American College of Rheumatology Damage Index (SDI) (mean SDI 4.75 vs 2.05, p<0.001) and increased mortality risk in a 2-year follow-up (12.50% vs 1.08%, p=0.002). CONCLUSION: In our cohort, 7.96% of patients with SLE had an intermediate or high PH probability. By RHC, six patients (2.99%) met the ESC/European Respiratory Society criteria for PH and four (1.99%) for PAH. The main risk factors were older age, cardiorespiratory symptoms, serositis, anti-Ro, cardiac biomarkers and altered PFTs. PH was a severe SLE complication, suggesting the need for earlier diagnosis through data-driven screening to reduce associated morbidity and mortality.


Subject(s)
Hypertension, Pulmonary , Lupus Erythematosus, Systemic , Serositis , Humans , Female , Male , Hypertension, Pulmonary/diagnosis , Hypertension, Pulmonary/epidemiology , Hypertension, Pulmonary/etiology , Prevalence , Prospective Studies , Echocardiography , Lupus Erythematosus, Systemic/complications , Lupus Erythematosus, Systemic/epidemiology , Biomarkers
9.
Catheter Cardiovasc Interv ; 103(3): 482-489, 2024 02.
Article in English | MEDLINE | ID: mdl-38204382

ABSTRACT

OBJECTIVES: The aim of this study was to analyze the efficacy and safety of percutaneous balloon pericardiotomy (PBP) in oncological patients who present with a malignant pericardial effusion (MPE). BACKGROUND: The use of PBP as a treatment for MPE is not standardized due to the limited evidence. Furthermore, the performance of a second PBP for a recurrence after a first procedure is controversial. METHODS: The BALTO Registry (BALloon pericardioTomy in Oncological patients) is a prospective, single-center, observational registry that includes consecutive PBP performed for MPE from October 2007 to February 2022. Clinical and procedural, characteristics, as well as clinical outcome were analyzed. RESULTS: Seventy-six PBP were performed in 61 patients (65% female). Mean age was of 66.4 ± 11.2 years. In 15 cases, a second PBP procedure was performed due to recurrence despite the first PBP. The procedure could be performed effectively in all cases with only two serious complications. Ninety-five percent of cases were discharged alive from the hospital. During a median follow-up of 6.3 months (interquartile range [IQR], 0.9-10.8), MPE recurred in 24.5% cases although no recurrences were reported after the second procedure. No evidence of malignant pleural effusion developed on follow-up. The median overall survival time was 5.8 months (IQR, 0.8-10.2) and the time to recurrence after the first PBP was 2.4 months (IQR, 0.7-4.5). CONCLUSIONS: PBP is a safe and effective treatment for MPE. It could be considered an acceptable therapy in most MPE, even in those who recur after a first procedure.


Subject(s)
Balloon Occlusion , Pericardial Effusion , Humans , Female , Middle Aged , Aged , Male , Pericardiectomy/adverse effects , Treatment Outcome , Prospective Studies , Pericardial Effusion/diagnostic imaging , Pericardial Effusion/etiology , Pericardial Effusion/therapy , Balloon Occlusion/adverse effects
10.
Cardiovasc Revasc Med ; 59: 93-98, 2024 Feb.
Article in English | MEDLINE | ID: mdl-37723011

ABSTRACT

INTRODUCTION: Clinical events may occur after percutaneous coronary intervention (PCI), particularly in complex lesions and complex patients. The optimization of PCI result, using pressure guidewire and intracoronary imaging techniques, may reduce the risk of these events. The hypothesis of the present study is that the clinical outcome of patients with indication of PCI and coronary stent implantation that are at high risk of events can be improved with an unrestricted use of intracoronary tools that allow PCI optimization. METHODS AND ANALYSIS: Observational prospective multicenter international study, with a follow-up of 12 months, including 1064 patients treated with a cobalt­chromium everolimus-eluting stent. Inclusion criteria include any of the following: Lesion length > 28 mm; Reference vessel diameter < 2.5 mm or > 4.25 mm; Chronic total occlusion; Bifurcation with side branch ≥2.0 mm;Ostial lesion; Left main lesion; In-stent restenosis; >2 lesions stented in the same vessel; Treatment of >2 vessels; Acute myocardial infarction; Renal insufficiency; Left ventricular ejection fraction <30 %; Staged procedure. The control group will be comprised by a similar number of matched patients included in the "extended risk" cohort of the XIENCE V USA study. The primary endpoint will be the 1-year rate of target lesion failure (TLF) (composite of ischemia-driven TLR, myocardial infarction (MI) related to the target vessel, or cardiac death related to the target vessel). Secondary endpoints will include overall mortality, cardiovascular mortality, acute myocardial infarction, TVR, TLR, target vessel failure, and definitive or probable stent thrombosis at 1 year. IMPLICATIONS: The ongoing OPTI-XIENCE study will contribute to the growing evidence supporting the use of intra-coronary imaging techniques for stent optimization in patients with complex coronary lesions.


Subject(s)
Coronary Artery Disease , Drug-Eluting Stents , Myocardial Infarction , Percutaneous Coronary Intervention , Humans , Coronary Artery Disease/diagnostic imaging , Coronary Artery Disease/therapy , Coronary Artery Disease/etiology , Myocardial Infarction/etiology , Percutaneous Coronary Intervention/adverse effects , Prospective Studies , Prosthesis Design , Sirolimus , Stroke Volume , Treatment Outcome , Ventricular Function, Left
11.
Front Cardiovasc Med ; 10: 1199475, 2023.
Article in English | MEDLINE | ID: mdl-37745092

ABSTRACT

Background: Third generation drug-eluting stents (DES) potentially offer better technical performance and reduced neointimal proliferation than previous generation DES. The XLIMIT non-inferiority trial evaluated the performance of the Xlimus (a novel sirolimus-eluting coronary stent system) in terms of endothelialization and tissue healing compared to the bioresorbable polymer Synergy DES. Methods: A total of 177 patients undergoing percutaneous coronary intervention (PCI) were randomized in a 2:1 ratio (2 Xlimus: 1 Synergy). The primary endpoints, defined as the in-stent neointimal volume weighted by the sum of the lengths of the implanted stent (ISNV) and the in-stent neointimal percent volume obstruction (%VO) were evaluated at 6-9 months by means of optical coherence tomography (OCT). Additional OCT parameters as well as clinical endpoints were also collected. Results: Most of the patients were males (77.4%), and the mean age was 64 years. One third of the population had stable angina/silent ischemia. A total of 300 stents (237 lesions) were analyzed: 198 (152 lesions) were in the Xlimus group, and 102 (85 lesions) in the Synergy group. The ISNV in the Xlimus group was 30.7 ± 24.5 mm3 while in the Synergy group it was 26.5 ± 26.7 mm3: the difference between the two means was 0.08 (-0, 04-0, 45), p = 0.018, thus meeting the non-inferiority hypothesis. The %VO was 16.3% ± 10.4% and 13.3% ± 10.8% in the Xlimus and Synergy groups, respectively: the difference between the two means was 3.0 (-0, 06-4, 2), (p = 0.01), thus meeting the non-inferiority hypothesis. No difference was found with respect to the secondary OCT endpoints as well as for clinical endpoints. Conclusions: The study results confirm that the biological interaction of the Xlimus and Synergy DES with the coronary artery is comparable, and that translates in very reassuring OCT parameters at follow-up: as such, the Xlimus is non-inferior to the Synergy. Clinical Trial Registration: ClinicalTrials.gov, identifier (NCT03745053).

12.
Microvasc Res ; 150: 104598, 2023 11.
Article in English | MEDLINE | ID: mdl-37633337

ABSTRACT

In the 20th century, research focused on cholesterol and lipoproteins as the key mechanism in establishing atherosclerotic cardiovascular disease (ASCVD). Given that some studies demonstrated subclinical atherosclerosis in subjects without conventional cardiovascular risk factors, the elevated low-density lipoprotein (LDL) levels alone cannot account for the entire burden of atherosclerosis. Hence, large-scale clinical trials demonstrated the operation of immune and inflammatory pathways in ASCVD. In this regard, the evidence establishes that cells of the immune system, both the innate (neutrophils, macrophages) and adaptive (T cell and other lymphocytes) limbs, contribute to atherosclerosis and atherothrombosis. Besides, basic science studies have identified proatherogenic cytokines such as interleukin (IL)-1, IL-12, and IL-18. In this regard, some studies showed that antiinflammatory therapy targeting the immune system by modulating or blocking interleukins, also known as anti-cytokine therapy, can reduce the risk of major cardiovascular adverse events. The neutrophils play a key role in the innate immune system, representing the acute phase of an inflammatory response. In contrast, lymphocytes represent the adaptive immune system and promote the induction of autoimmune inflammation, especially in the chronic inflammatory response. Through the literature review, we will highlight the inflammatory pathway for the physiopathology of ASCVD, HF, and COVID-19. In this regard, the neutrophil-to-lymphocyte ratio (NLR) integrates the innate immune and adaptive immune systems, making the NLR a biomarker of inflammation. In addition, we provided an update on the evidence showing that high NLR is associated with worse prognosis in heart failure (HF), ASCVD, and COVID-19, as well as their clinical applications showing that the normalization of NLR after anti-cytokine therapy is a potential predictor of therapy responsiveness and is associated with reduction of major adverse cardiovascular events.


Subject(s)
Atherosclerosis , COVID-19 , Cardiovascular Diseases , Heart Failure , Humans , Cardiovascular Diseases/diagnosis , Neutrophils , Prognosis , Heart Failure/diagnosis , Heart Failure/drug therapy , Lymphocytes , Biomarkers , Chronic Disease
14.
J Invasive Cardiol ; 35(4): E223-E224, 2023 04.
Article in English | MEDLINE | ID: mdl-37029998

ABSTRACT

Cardiac computed tomography (CT) scan was performed in a 69-year-old male with atrial fibrillation radiofrequency ablation who was admitted for transcatheter angioplasty of left inferior pulmonary vein (LIPV) stenosis due to recurrent hemoptysis. CT showed complete ostial occlusion in the area of the LIPV. Occlusion of the pulmonary vein ostium is a rare complication. We describe the successful use of chronic occlusion techniques in the treatment of this patient.


Subject(s)
Atrial Fibrillation , Catheter Ablation , Pulmonary Veins , Vascular Diseases , Male , Humans , Aged , Pulmonary Veins/diagnostic imaging , Pulmonary Veins/surgery , Atrial Fibrillation/diagnosis , Atrial Fibrillation/surgery , Atrial Fibrillation/complications , Angioplasty/adverse effects , Vascular Diseases/surgery , Constriction, Pathologic/diagnosis , Constriction, Pathologic/etiology , Constriction, Pathologic/surgery , Catheter Ablation/adverse effects
15.
Eur Heart J Acute Cardiovasc Care ; 12(5): 299-305, 2023 May 04.
Article in English | MEDLINE | ID: mdl-37010101

ABSTRACT

AIMS: Spontaneous coronary artery dissection (SCAD) is a relatively infrequent cause of acute coronary syndrome. Clinical features, angiographic findings, management, and outcomes of SCAD patients who present reduced left ventricular ejection fraction (LVEF) remain unknown. METHODS AND RESULTS: The Spanish multicentre prospective SCAD registry (NCT03607981), included 389 consecutive patients with SCAD. In 348 of these patients, LVEF could be assessed by echocardiography during the index admission. Characteristics and outcomes of patients with preserved LVEF (LVEF ≥50%, n = 295, 85%) were compared with those with reduced LVEF (LVEF <50%, n = 53, 15%). Mean age was 54 years and 90% of patients in both groups were women. The most frequent clinical presentation in patients with reduced LVEF was ST-segment elevation myocardial infarction (STEMI) (62% vs. 36%, P < 0.001), especially anterior STEMI. Proximal coronary segment and multi-segment involvement were also significantly more frequent in these patients. No differences were found on initial revascularization between groups. Patients with reduced LVEF significantly received more often neurohormonal antagonist therapy, and less frequently aspirin. In-hospital events were more frequent in these patients (13% vs. 5%, P = 0.01), with higher rates of death, cardiogenic shock, ventricular arrhythmia, and stroke. During a median follow-up of 28 months, the occurrence of a combined adverse event did not statistically differ between the two groups (19% vs. 12%, P = 0.13). However, patients with reduced LVEF had higher mortality (9% vs. 0.7%, P < 0.001) and readmission rates for heart failure (HF) (4% vs. 0.3%, P = 0.01). CONCLUSION: Patients with SCAD and reduced LVEF show differences in clinical characteristics and angiographic findings compared with SCAD patients with preserved LVEF. Although these patients receive specific medications at discharge, they had higher mortality and readmission rates for HF during follow-up.


Subject(s)
Percutaneous Coronary Intervention , ST Elevation Myocardial Infarction , Ventricular Dysfunction, Left , Humans , Female , Middle Aged , Male , Prognosis , Ventricular Function, Left , Stroke Volume , ST Elevation Myocardial Infarction/complications , ST Elevation Myocardial Infarction/diagnosis , Coronary Vessels , Prospective Studies , Percutaneous Coronary Intervention/methods , Ventricular Dysfunction, Left/diagnosis , Ventricular Dysfunction, Left/etiology , Coronary Angiography
17.
J Invasive Cardiol ; 35(2): E103-E105, 2023 02.
Article in English | MEDLINE | ID: mdl-36735872

ABSTRACT

To the best of our knowledge, this case represents the first patient with Mitraclip, Amplatzer, and TricValve devices with a profound clinical improvement and long-term follow-up. In addition, this case illustrates how the treatment of high-risk patients with polyvalvular disease has changed in the last few years.


Subject(s)
Heart Valve Prosthesis Implantation , Mitral Valve Insufficiency , Humans , Mitral Valve/diagnostic imaging , Mitral Valve/surgery , Mitral Valve Insufficiency/diagnosis , Mitral Valve Insufficiency/surgery , Mitral Valve Insufficiency/etiology , Cardiac Catheterization/adverse effects , Heart Valve Prosthesis Implantation/adverse effects , Treatment Outcome
18.
J Invasive Cardiol ; 35(2): E110-E111, 2023 02.
Article in English | MEDLINE | ID: mdl-36735875

ABSTRACT

An 86-year-old patient with non-valvular atrial fibrillation was referred to our institution to undergo a left atrial appendage (LAA) closure for recurrent gastrointestinal bleeding on direct oral anticoagulants. The transesophageal echocardiogram (TEE) performed the previous day evaluated the morphology and dimensions of the LAA and ruled out any thrombus. During the procedure, a pigtail catheter was inserted into the LAA, observing an unusual image we describe as a culde- sac, without an anomalous connection with any drainage in other vessel or cavity. After additional imaging studies, we concluded that it was morphology related to LAA, which we have termed the "water-gun" morphology. Four morphologies have been described based on the shape of the central and secondary lobes. To the best of our knowledge, this is the first description of a fifth type, which was shown to be effectively closed with current closure devices.


Subject(s)
Atrial Appendage , Atrial Fibrillation , Cardiac Surgical Procedures , Thrombosis , Humans , Aged, 80 and over , Atrial Appendage/diagnostic imaging , Atrial Appendage/surgery , Atrial Fibrillation/complications , Atrial Fibrillation/diagnosis , Atrial Fibrillation/surgery , Echocardiography, Transesophageal , Treatment Outcome
SELECTION OF CITATIONS
SEARCH DETAIL
...