Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 3 de 3
Filter
Add more filters










Database
Language
Publication year range
1.
Global Spine J ; 13(1): 89-96, 2023 Jan.
Article in English | MEDLINE | ID: mdl-33648356

ABSTRACT

STUDY DESIGN: Prospective observational study. OBJECTIVE: In ACDF, graft failure and subsidence are common complications of surgery. Depending on the cervical fixation, different biomechanical characteristics are applied on the grafts. This aims to describe the incidence of cervical spacer failure in patients with cervical degenerative condition according to the cervical fixation method and sagittal balance. METHOD: From November 2011 to December 2015, 262 patients who underwent cervical spine surgery were enrolled prospectively. Patients were divided into 3 groups based on fixation method: anterior plate/screw (APS), posterior lateral mass screw (LMS), pedicle screw (PPS) groups. Serial X-rays and CT scans were utilized to evaluate radiologic outcomes. RESULTS: Mean patient ages were 56.1 years in the APS group, 61.5 years in the LMS group, and 57.6 years in the PPS group (P = 0.002). Allospacer failure was most common in the APS group, compared to the LMS and PPS groups (chi-square, P = 0.038). Longer fusion level was associated with greater allospacer failure (Baseline 2 level surgery; Odds ratio (OR) 3.4 in 3 level, 15.2 in 4 level, P = 0.036,0.013). Higher T1 slope was correlated with less allospacer failure (OR 0.875, P = 0.001). ORs of allospacer failure in the LMS and PPS groups were 0.04 and 0.02, respectively, (P = 0.01, 0.01), compared with the APS group. CONCLUSION: This study was able to show that allospacer failure in multi-level ACDF surgery is more common with a longer fusion length, less postoperative T1 slope, and an anterior plate-screws technique. Pedicle screws provided the best biomechanical stability among the 3 constructs.

2.
J Clin Med ; 10(9)2021 May 05.
Article in English | MEDLINE | ID: mdl-34062994

ABSTRACT

BACKGROUND: Few studies have investigated associations between hand grip strength (HGS) and the surgical outcomes of degenerative cervical myelopathy (DCM). METHODS: This study was designed as a prospective observational study of 203 patients who had undergone fusion surgery for DCM. We divided the patients according to sex and HGS differences. Clinical outcome parameters, including HGS, a fall diary and four functional mobility tests (alternative step test, six-meter walk test, timed up and go test, and sit-to-stand test) were measured preoperatively, at 3 months and 1 year after surgery. RESULTS: Mean patient ages were 59.93 years in the male group and 67.33 years in the female group (p = 0.000; independent t-test). The mean HGS of both hands improved significantly at postoperative 3 months and 1 year in all patients (p = 0.000 for both; ANOVA). In male patients, preoperative risk of falls was negatively correlated with HGS (p = 0.000). In female patients, pre- and postoperative risk of falls were correlated negatively with HGS (p = 0.000). The postoperative incidence of falls decreased in both groups (p = 0.000) Conclusions: Postoperative HGS in patients with DCM is correlated with postoperative falls and functional outcome differently, when comparing male and female patients, for predicting favorable outcomes and neurologic deficit recovery after surgery in DCM patients.

3.
J Clin Med ; 10(9)2021 May 10.
Article in English | MEDLINE | ID: mdl-34068531

ABSTRACT

BACKGROUND: Anterior cervical discectomy and fusion surgery is a common procedure for degenerative cervical spine. This describes allospacer and implant-related outcomes, comparing medium plate-low screw angle and short plate-high screw angle techniques. METHODS: From January 2016 to June 2019, 79 patients who underwent ACDF were prospectively enrolled. Patients were divided, depending on the plate-screw system used: medium plate-low screw angle (12.3 ± 2.5 to 13.2 ± 3.2 degrees), and short plate-high screw angle (22.8 ± 5.3 to 23.3 ± 4.7 degrees). Subsidence, ALOD, and sagittal cervical balance were analyzed using lateral cervical X-rays. NDI and VAS scores were also evaluated. RESULTS: Age for medium plate-low-angled screw group is 58.0 ± 11.3 years, and 55.3 ± 12.0 in the short plate-high-angled screw group (p-value = 0.313). Groups were comparable in mean NDI (p-value = 0.347), VAS (p-value = 0.156), C2-C7 SVA, (p-value = 0.981), and lordosis angle (p-value = 0.836) at 1-year post-surgery. Subsidence was higher in the medium plate-low-angled screw than in the short plate-high-angled screw (25% and 8.5%, respectively, p-value = 0.045). ALOD is also more common in the medium plate group (p-value = 0.045). CONCLUSION: Use of a short plate and insertion of high-angled screws (more than 20 degrees) has less chance of subsidence and occurrence of ALOD than the traditional technique of using medium plate and low angle.

SELECTION OF CITATIONS
SEARCH DETAIL
...