1.
Zhongguo Yi Liao Qi Xie Za Zhi ; 47(2): 178-184, 2023 Feb 08.
Article in Chinese | MEDLINE | ID: mdl-37096472

ABSTRACT

The emergence of smart phones has not only brought extensive changes to people's way of life, but also provided a new research platform for the expansion and application of science and technology. Technicians have combined immunoassay methods with smart phone sensing technology to develop a variety of smartphone-based biological sample analysis and detection sensing systems, promoting the application of immunoassay methods in POCT fields. In this review, we summarize the researches and applications of smart-phone in the field of immune analysis. According to the different sensors and detection objects, these applications can be divided into four aspects: camera-based spectrometer, camera-based enzyme reader, camera-based strip reader and spectrophotometer based on environmental light sensor. This study also briefly discusses some limitations of current smart phone application in immune analysis, and prospects the future applicability of smart phone sensing system.


Subject(s)
Smartphone , Technology , Humans , Immunoassay/methods
2.
Zhongguo Yi Liao Qi Xie Za Zhi ; 46(3): 296-301, 2022 May 30.
Article in Chinese | MEDLINE | ID: mdl-35678440

ABSTRACT

Blood glucose monitoring is of great significance to diabetic patients, and the development of rapid, accurate and real-time glucose detection technology has become a research hotspot nowadays. This study introduces the concept and classification of the enzyme-free glucose sensor, expounds enzymefree glucose sensor electrode characterization methods and the application progress of different materials in enzyme-free blood glucose sensors. Meanwhile, some problems of enzyme-free glucose sensor existing in the current research and its future application prospects also will be discussed.


Subject(s)
Blood Glucose Self-Monitoring , Blood Glucose , Electrodes , Glucose , Humans , Monitoring, Physiologic
3.
Zhongguo Yi Liao Qi Xie Za Zhi ; 45(6): 645-649, 2021 Nov 30.
Article in Chinese | MEDLINE | ID: mdl-34862778

ABSTRACT

In order to solve the problem of continuous monitoring and automatic regulation of patient airbag pressure in intensive care unit, the study designed an intelligent management system of artificial airway airbag pressure. It can realize real-time monitoring and automatic control of airbag pressure. Its pressure data was sent to the PC in real time by the serial port. It can realize the display, store, review and analysis of pressure data. Its clinical application effect was discussed. Experiments showed that the system can monitor airbag pressure in real time and control the pressure to stabilize at 25~30 cmH2O. Compared with the control group, the experimental group had a statistically significant difference in the operation time of monitoring patients' airbag pressure, changes in airbag pressure, the instantaneous maximum value during nursing operation, and the number of aspiration and reflux cases. The clinical application of the system can reduce the workload of medical staff greatly, effectively reduce the number of patients with aspiration and reflux, reduce the incidence of ventilator pneumonia.


Subject(s)
Air Bags , Critical Care , Humans , Intensive Care Units , Monitoring, Physiologic
4.
Zhongguo Yi Liao Qi Xie Za Zhi ; 45(6): 698-701, 2021 Nov 30.
Article in Chinese | MEDLINE | ID: mdl-34862788

ABSTRACT

Ramping-up is the magnet current injection procedure which is under the control of resistance, voltage, current lead temperature, magnet pressure, temperature and so on. In this procedure, the factors related to the stability of the magnet such as, magnet temperature, pressure and currents are constantly changing. This procedure is the main step which the magnet-quench occurs in. This study uses the data collected during 7 years and SIMENS MRI ramping-up theory, in order to help engineers understand the key factors to reduce the magnet quench during the ramping up procedure.


Subject(s)
Magnets , Temperature
5.
Zhongguo Yi Liao Qi Xie Za Zhi ; 44(4): 367-370, 2020 Apr 08.
Article in Chinese | MEDLINE | ID: mdl-32762216

ABSTRACT

The modifications of slices, flip angle, SAR mode and TR time are required when the SAR exceeds the limits. The scan time and image quality are affected by those. This study analyzes the SAR from the basic side. With the principle diagram of SIEMENS 1.5 T AVANTO and 3.0 T VERIO MRIS, the trouble shooting procedure of SAR problem is reached both in application and problem sides.


Subject(s)
Image Enhancement , Algorithms
6.
Zhongguo Yi Liao Qi Xie Za Zhi ; 43(4): 279-281, 2019 Jul 30.
Article in Chinese | MEDLINE | ID: mdl-31460721

ABSTRACT

3D printing technology is a kind of manufacturing technology for increasing materials. Based on its advantages of rapid prototyping, digitalization and customization, it can effectively meet the needs of personalized and accurate medical treatment, and has been widely studied and applied in the medical field. This paper introduces the principle, technology and materials of 3D printing technology, and describes the research and application status of the technology in medical field. Meanwhile, some problems of 3D printing technology existing in the current development and its future application prospects also will be discussed.


Subject(s)
Medicine , Printing, Three-Dimensional , Medicine/trends , Research/trends