Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 2 de 2
Filter
Add more filters










Database
Publication year range
1.
Yakugaku Zasshi ; 134(11): 1209-17, 2014.
Article in Japanese | MEDLINE | ID: mdl-25366918

ABSTRACT

Carboxymethyl cellulose (CMC) is one of the most important cellulose derivatives and used in the fields of food, pharmaceuticals, cosmetics, and paint. Fibrous CMC is used an antiadhesive material to prevent postoperative wound adhesions. The degree of substitution and distribution of the substituent (i.e., the carboxymethyl group) are the most important parameters for the function of CMC. Thus, CMC used for antiadhesive material must be carefully evaluated, because the CMC product is retained in patients' bodies over the long term. Although identification tests of CMC are defined in the Japanese Pharmacopoeia, it is difficult to evaluate its structure using those tests. In the present study, we propose improved methods for evaluating CMC products by analyzing monosaccharides after hydrolysis.


Subject(s)
Carboxymethylcellulose Sodium/chemistry , Chromatography, Liquid , Humans , Mass Spectrometry , Reproducibility of Results , Tissue Adhesions
2.
J Nippon Med Sch ; 77(2): 106-10, 2010 Apr.
Article in English | MEDLINE | ID: mdl-20453423

ABSTRACT

A number of recent reports have highlighted the usefulness of laparoscopic surgery for pancreatic surgery; however, the procedure is not yet standard because of its technical challenges. Using an endoscopic surgical spacer (SECUREA) that we developed, we performed laparoscopic enucleation of a pancreatic tumor in a patient with pancreatic mucinous cystadenoma. The SECUREA is a polyurethane sponge with a radiopaque marker. It is elliptic-cylindrical and measures 6.5 cm on the major axis, 3.5 cm on the minor axis, and 2 cm in height. Herein, we report the intraoperative findings and examine the usefulness of SECUREA for laparoscopic enucleation. The spacer was introduced into the abdominal cavity through a 12-mm trocar, and was grasped with forceps to isolate or extend organs and tissues, thereby ensuring a safe and relatively uncontaminated surgical field. In addition, the high absorptiveness and water-holding capacity of the sponge facilitated removal of exudate, which created a clearer operative field and reduced the technical challenges of drainage manipulation. Indeed, replacement of the sponge was unnecessary because it returned to its original state after the liquid it contained had been aspirated. Our findings suggest that the SECUREA increases safety and reduces the technical difficulties of laparoscopic enucleation.


Subject(s)
Cystadenoma, Mucinous/surgery , Laparoscopy , Pancreatic Neoplasms/surgery , Surgical Sponges , Cystadenoma, Mucinous/diagnostic imaging , Equipment Design , Female , Humans , Middle Aged , Pancreatic Neoplasms/diagnostic imaging , Polyurethanes , Suction , Therapeutic Irrigation , Tomography, X-Ray Computed , Treatment Outcome
SELECTION OF CITATIONS
SEARCH DETAIL
...