1.
J Mech Behav Biomed Mater ; 125: 104879, 2022 01.
Article in English | MEDLINE | ID: mdl-34736021

ABSTRACT

The elastic modulus at the single trabecular level is an important parameter for the understanding of the mechanical behavior of trabecular bone. Current methods are commonly limited by the irregular trabecular shape and the accuracy of displacement measurement. The aim of this study was to propose a method to estimate the trabecular modulus overcoming some of these limitations. For high-precision displacement measurements, in-situ compression within a synchrotron radiation based X-ray tomograph was used. Trabecular displacements were subsequently estimated by a global digital volume correlation algorithm, followed by high-resolution finite element analyses to account for the irregular geometry. The trabecular elastic moduli were then estimated by comparing the loads from the finite element analyses with those of the experiments. With this strategy, the average elastic modulus was estimated to 3.83 ± 0.54 GPa for three human trabeculae samples. Though limited by the sample size, the demonstrated method shows a potential to estimate the mechanical properties at the single trabecular level.


Subject(s)
Algorithms , Elastic Modulus , Humans
2.
Soft Matter ; 13(21): 3936-3945, 2017 May 31.
Article in English | MEDLINE | ID: mdl-28504291

ABSTRACT

Soft tissues possess remarkable mechanical strength for their high water content, which is hard to mimic in synthetic materials. Here, we demonstrate how strain-induced stiffening in hydrogels plays a major role in mimicking the mechanical properties of collagenous soft tissues. In particular, nanocellulose reinforced polyvinyl alcohol (PVA) hydrogels of exceptionally high water content (90-93 wt%) are shown to exhibit collagen-like mechanical behavior typical for soft tissues. High water content and co-existence of both soft and rigid domains in the gel network are the main factors responsible for strain-induced stiffening. This observed effect due to the alignment of rigid components of the hydrogel is simulated through modeling and visualized through strain-induced birefringence experiments. Design parameters such as nanocellulose aspect ratio and solvent composition are also shown to be important to control the mechanical properties. In addition, owing to their transparency (90-95% at 550 nm) and hyperelastic properties (250-350% strain), the described hydrogels are promising materials for biomedical applications, especially in ophthalmology.


Subject(s)
Biomimetic Materials/chemistry , Cellulose/chemistry , Collagen/metabolism , Nanostructures/chemistry , Polyvinyl Alcohol/chemistry , Stress, Mechanical , Models, Molecular , Molecular Conformation , Water/chemistry
3.
Biomech Model Mechanobiol ; 16(4): 1349-1359, 2017 08.
Article in English | MEDLINE | ID: mdl-28265781

ABSTRACT

The mechanical fixation of endosseous implants, such as screws, in trabecular bone is challenging because of the complex porous microstructure. Development of new screw designs to improve fracture fixation, especially in high-porosity osteoporotic bone, requires a profound understanding of how the structural system implant/trabeculae interacts when it is subjected to mechanical load. In this study, pull-out tests of screw implants were performed. Screws were first inserted into the trabecular bone of rabbit femurs and then pulled out from the bone inside a computational tomography scanner. The tests were interrupted at certain load steps to acquire 3D images. The images were then analysed with a digital volume correlation technique to estimate deformation and strain fields inside the bone during the tests. The results indicate that the highest shear strains are concentrated between the inner and outer thread diameter, whereas compressive strains are found at larger distances from the screw. Tensile strains were somewhat smaller. Strain concentrations and the location of trabecular failures provide experimental information that could be used in the development of new screw designs and/or to validate numerical simulations.


Subject(s)
Bone Screws , Cancellous Bone , Animals , Biomechanical Phenomena , Bone Screws/standards , Cancellous Bone/surgery , Fracture Fixation/instrumentation , Imaging, Three-Dimensional , Models, Animal , Rabbits , X-Ray Microtomography
4.
ACS Biomater Sci Eng ; 2(11): 2072-2079, 2016 Nov 14.
Article in English | MEDLINE | ID: mdl-33440543

ABSTRACT

A nanocellulose-reinforced poly(vinyl alcohol) hydrogel material of exceptionally high water content for ophthalmic applications is presented (>90 wt %), which also features a hitherto unprecedented combination of optical, mechanical, viscoelastic, oxygen permeability, and biocompatibility properties. The hydrogel combines the desired softness with remarkable strain-dependent mechanical strength and thereby demonstrates hyperelastic, rubber-like mechanical properties. The observed unusual mechanical behavior is due to both high water content and the combination of relatively stiff cellulose nanowhiskers entangled in a soft polymer matrix of poly(vinyl alcohol) (PVA), thus mimicking the structural characteristics of the cornea's main constituents, i.e., water and collagen.

5.
J Struct Biol ; 185(1): 89-98, 2014 Jan.
Article in English | MEDLINE | ID: mdl-24184469

ABSTRACT

Compression wood conifer tracheids show different swelling and stiffness properties than those of usual normal wood, which has a practical function in the living plant: when a conifer shoot is moved from its vertical position, compression wood is formed in the under part of the shoot. The growth rate of the compression wood is faster than in the upper part resulting in a renewed horizontal growth. The actuating and load-carrying function of the compression wood is addressed, on the basis of its special ultrastructure and shape of the tracheids. As a first step, a quantitative model is developed to predict the difference of moisture-induced expansion and axial stiffness between normal wood and compression wood. The model is based on a state space approach using concentric cylinders with anisotropic helical structure for each cell-wall layer, whose hygroelastic properties are in turn determined by a self-consistent concentric cylinder assemblage of the constituent wood polymers. The predicted properties compare well with experimental results found in the literature. Significant differences in both stiffness and hygroexpansion are found for normal and compression wood, primarily due to the large difference in microfibril angle and lignin content. On the basis of these numerical results, some functional arguments for the reason of high microfibril angle, high lignin content and cylindrical structure of compression wood tracheids are supported.


Subject(s)
Wood/physiology , Wood/ultrastructure , Cell Wall/metabolism , Cell Wall/physiology , Cell Wall/ultrastructure , Lignin/metabolism , Lignin/ultrastructure , Microfibrils/metabolism , Microfibrils/ultrastructure , Polymers/metabolism , Pressure
SELECTION OF CITATIONS