Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 2 de 2
Filter
Add more filters










Database
Language
Publication year range
1.
Anal Chim Acta ; 1096: 120-129, 2020 Feb 01.
Article in English | MEDLINE | ID: mdl-31883578

ABSTRACT

We report a microfluidic immunosensor for the electrochemical determination of IgG antibodies anti-Toxocara canis (IgG anti-T. canis). In order to improve the selectivity and sensitivity of the sensor, core-shell gold-ferric oxide nanoparticles (AuNPs@Fe3O4), and ordered mesoporous carbon (CMK-8) in chitosan (CH) were used. IgG anti-T. canis antibodies detection was carried out using a non-competitive immunoassay, in which excretory secretory antigens from T. canis second-stage larvae (TES) were covalently immobilized on AuNPs@Fe3O4. CMK-8-CH and AuNPs@Fe3O4 were characterized by transmission electron microscopy, scanning electron microscopy, energy dispersive spectrometry, cyclic voltammetry, electrochemical impedance spectroscopy, and N2 adsorption-desorption isotherms. Antibodies present in serum samples immunologically reacted with TES, and then were quantified by using a second antibody labeled with horseradish peroxidase (HRP-anti-IgG). HRP catalyzes the reduction from H2O2 to H2O with the subsequent oxidation of catechol (H2Q) to p-benzoquinone (Q). The enzymatic product was detected electrochemically at _100 mV on a modified sputtered gold electrode. The detection limit was 0.10 ng mL-1, and the coefficients of intra- and inter-assay variation were less than 6%, with a total assay time of 20 min. As can be seen, the electrochemical immunosensor is a useful tool for in situ IgG antibodies anti-T. canis determination.


Subject(s)
Antibodies, Helminth/immunology , Gold/chemistry , Metal Nanoparticles/chemistry , Microfluidic Analytical Techniques/instrumentation , Toxocara canis/immunology , Toxocariasis/immunology , Animals , Antibodies, Helminth/blood , Biosensing Techniques/instrumentation , Carbon/chemistry , Electrochemical Techniques/instrumentation , Equipment Design , Ferrosoferric Oxide/chemistry , Humans , Immunoassay/instrumentation , Limit of Detection , Porosity , Toxocariasis/blood
2.
Anal Biochem ; 564-565: 116-122, 2019 01 01.
Article in English | MEDLINE | ID: mdl-30393087

ABSTRACT

This article describes a microfluidic LIF immunosensor for the quantitative determination of anti-Toxoplasma gondii IgG (anti-T. gondii) specific antibodies. The serological detection of these antibodies plays a crucial role in the clinical diagnosis of toxoplasmosis. Zinc oxide nanoparticles (ZnO-NPs) obtained by wet chemical procedure were covered with chitosan and then used to conjugate T-gondii antigens into the central microfluidic channel. Serum samples containing anti-T-gondii IgG antibodies were injected into the immunosensor where they interact immunologically with T. gondii antigens. Bound antibodies were quantified by the addition of anti-IgG antibodies labeled whit alkaline phosphatase (ALP). ALP enzymatically converts the non-fluorescent 4-methylumbelliferyl phosphate (4-MUP) to soluble fluorescent methylumbelliferone that was measured using excitation at 355 nm and emission at 440 nm. The relative fluorescent response of methylumbelliferone is proportional to the concentration of anti-T. gondii IgG antibodies. The coefficients of variation are less than 4.73% for within-day assays and less than 6.34% for between-day assays. Results acquired by LIF immunosensor agree with those obtained by enzyme-linked immunosorbent assay method, suggesting that the designed sensor represents a promising tool for the quantitative determination of anti-T. gondii IgG antibodies of clinical samples.


Subject(s)
Chitosan/chemistry , Nanoparticles/chemistry , Toxoplasmosis/diagnosis , Zinc Oxide/chemistry , Alkaline Phosphatase/metabolism , Antibodies, Protozoan/metabolism , Enzyme-Linked Immunosorbent Assay , Humans , Immunoglobulin G/metabolism , Toxoplasmosis/blood
SELECTION OF CITATIONS
SEARCH DETAIL
...