1.
Nat Commun ; 15(1): 64, 2024 01 02.
Article in English | MEDLINE | ID: mdl-38167848

ABSTRACT

There is an urgent clinical need for a treatment regimen that addresses the underlying pathophysiology of ventricular arrhythmias, the leading cause of sudden cardiac death. The current report describes the design of an injectable hydrogel electrode and successful deployment in a pig model with access far more refined than any current pacing modalities allow. In addition to successful cardiac capture and pacing, analysis of surface ECG tracings and three-dimensional electroanatomic mapping revealed a QRS morphology comparable to native sinus rhythm, strongly suggesting the hydrogel electrode captures the deep septal bundle branches and Purkinje fibers. In an ablation model, electroanatomic mapping data demonstrated that the activation wavefront from the hydrogel reaches the mid-myocardium and endocardium much earlier than current single-point pacing modalities. Such uniform activation of broad swaths of tissue enables an opportunity to minimize the delayed myocardial conduction of heterogeneous tissue that underpins re-entry. Collectively, these studies demonstrate the feasibility of a new pacing modality that most closely resembles native conduction with the potential to eliminate lethal re-entrant arrhythmias and provide painless defibrillation.


Subject(s)
Bundle of His , Hydrogels , Animals , Swine , Bundle of His/physiology , Cardiac Pacing, Artificial/methods , Purkinje Fibers , Electrodes , Arrhythmias, Cardiac/therapy , Electrocardiography/methods
2.
Cardiovasc Drugs Ther ; 37(2): 323-340, 2023 04.
Article in English | MEDLINE | ID: mdl-34363570

ABSTRACT

Cardiac arrhythmias are a leading cause of morbidity and mortality in the developed world, estimated to be responsible for hundreds of thousands of deaths annually. Our understanding of the electrophysiological mechanisms of such arrhythmias has grown since they were formally characterized in the late nineteenth century, and this has led to the development of numerous devices and therapies that have markedly improved outcomes for patients affected by such conditions. Despite these advancements, the application of a single large shock remains the clinical standard for treating deadly tachyarrhythmias. Such defibrillating shocks are undoubtedly effective in terminating such arrhythmias; however, they are applied without forewarning, contributing to the patient's stress and anxiety; they can be intensely painful; and they can have adverse psychological and physiological effects on patients. In recent years, there has been interest in developing defibrillation protocols that can terminate arrhythmias without crossing the human pain threshold for energy delivery, generally estimated to be between 0.1 and 1 J. In this article, we review existing literature on the development of such low-energy defibrillation methods and their underlying mechanisms, in an attempt to broadly describe the current landscape of these technologies.


Subject(s)
Electric Countershock , Ventricular Fibrillation , Humans , Ventricular Fibrillation/etiology , Electric Countershock/adverse effects , Electric Countershock/methods , Arrhythmias, Cardiac/diagnosis , Arrhythmias, Cardiac/therapy , Arrhythmias, Cardiac/etiology , Electric Stimulation
3.
Article in English | MEDLINE | ID: mdl-35765469

ABSTRACT

There exists a gap in terms of the signals provided by pacemakers (i.e., intracardiac electrogram (EGM)) and the signals doctors use (i.e., 12-lead electrocardiogram (ECG)) to diagnose abnormal rhythms. Therefore, the former, even if remotely transmitted, are not sufficient for doctors to provide a precise diagnosis, let alone make a timely intervention. To close this gap and make a heuristic step towards real-time critical intervention in instant response to irregular and infrequent ventricular rhythms, we propose a new framework dubbed RT-RCG to automatically search for (1) efficient Deep Neural Network (DNN) structures and then (2) corresponding accelerators, to enable Real-Time and high-quality Reconstruction of ECG signals from EGM signals. Specifically, RT-RCG proposes a new DNN search space tailored for ECG reconstruction from EGM signals, and incorporates a differentiable acceleration search (DAS) engine to efficiently navigate over the large and discrete accelerator design space to generate optimized accelerators. Extensive experiments and ablation studies under various settings consistently validate the effectiveness of our RT-RCG. To the best of our knowledge, RT-RCG is the first to leverage neural architecture search (NAS) to simultaneously tackle both reconstruction efficacy and efficiency.

4.
J Cardiovasc Electrophysiol ; 33(7): 1507-1512, 2022 07.
Article in English | MEDLINE | ID: mdl-35437855

ABSTRACT

INTRODUCTION: In radiofrequency ablation procedures for cardiac arrhythmia, the efficacy of creating repeated lesions at the same location ("insurance lesions") remains poorly studied. We assessed the effect of type of tissue, power, and time on the resulting lesion geometry during such multiple ablation procedures. METHODS: A custom ex vivo ablation model was used to assess lesion formation. An ablation catheter was oriented perpendicular to the tissue and used to create lesions that varied by type of tissue (atrial or ventricular free wall), power (30 or 50 W), and time (30, 40, or 50 s for standard ablations and 5, 10, or 15 s for high-power, short-duration [HPSD] ablations). Lesion dimensions were recorded and then analyzed. Radiofrequency ablations were performed on 57 atrial tissue samples (28 HPSD, 29 standard) and 28 ventricular tissue samples (all standard). RESULTS: With ablation parameters held constant, performing multiple ablations significantly increased lesion depth in ventricular tissue when ablations were performed at 30 W for 50 s. No other set of ablation parameters was shown to affect the width or depth of the resulting lesions in either tissue type. CONCLUSION: Multiple ablations created with the same power and time, delivered within 30 s of each other at the same exact location, offer no meaningful benefit in lesion depth or width over single ablations, with the exception of ventricular ablation at 30 W for 50 s. Given the risks associated with excessive ablation, our results suggest that this practice should be re-evaluated by clinical electrophysiologists.


Subject(s)
Catheter Ablation , Insurance , Radiofrequency Ablation , Catheter Ablation/adverse effects , Catheter Ablation/methods , Heart Atria , Heart Ventricles , Humans , Radiofrequency Ablation/adverse effects
5.
IEEE Trans Biomed Eng ; 69(10): 3253-3264, 2022 10.
Article in English | MEDLINE | ID: mdl-35404808

ABSTRACT

OBJECTIVE: Local activation time (LAT) mapping of cardiac chambers is vital for targeted treatment of cardiac arrhythmias in catheter ablation procedures. Current methods require too many LAT observations for an accurate interpolation of the necessarily sparse LAT signal extracted from intracardiac electrograms (EGMs). Additionally, conventional performance metrics for LAT interpolation algorithms do not accurately measure the quality of interpolated maps. We propose, first, a novel method for spatial interpolation of the LAT signal which requires relatively few observations; second, a realistic sub-sampling protocol for LAT interpolation testing; and third, a new color-based metric for evaluation of interpolation quality that quantifies perceived differences in LAT maps. METHODS: We utilize a graph signal processing framework to reformulate the irregular spatial interpolation problem into a semi-supervised learning problem on the manifold with a closed-form solution. The metric proposed uses a color difference equation and color theory to quantify visual differences in generated LAT maps. RESULTS: We evaluate our approach on a dataset consisting of seven LAT maps from four patients obtained by the CARTO electroanatomic mapping system during premature ventricular complex (PVC) ablation procedures. Random sub-sampling and re-interpolation of the LAT observations show excellent accuracy for relatively few observations, achieving on average 6% lower error than state-of-the-art techniques for only 100 observations. CONCLUSION: Our study suggests that graph signal processing methods can improve LAT mapping for cardiac ablation procedures. SIGNIFICANCE: The proposed method can reduce patient time in surgery by decreasing the number of LAT observations needed for an accurate LAT map.


Subject(s)
Catheter Ablation , Ventricular Premature Complexes , Catheter Ablation/methods , Electrophysiologic Techniques, Cardiac/methods , Heart Rate , Humans , Signal Processing, Computer-Assisted
6.
Tex Heart Inst J ; 49(2)2022 03 01.
Article in English | MEDLINE | ID: mdl-35481862

ABSTRACT

Cardiac electrophysiology requires the processing of several patient-specific data points in real time to provide an accurate diagnosis and determine an optimal therapy. Expanding beyond the traditional tools that have been used to extract information from patient-specific data, machine learning offers a new set of advanced tools capable of revealing previously unknown data patterns and features. This new tool set can substantially improve the speed and level of confidence with which electrophysiologists can determine patient-specific diagnoses and therapies. The ability to process substantial amounts of data in real time also paves the way to novel techniques for data collection and visualization. Extended realities such as virtual and augmented reality can now enable the real-time visualization of 3-dimensional images in space. This enables improved preprocedural planning and intraprocedural interventions. Machine learning supplemented with novel visualization technologies could substantially improve patient care and outcomes by helping physicians to make more informed patient-specific decisions. This article presents current applications of machine learning and their use in cardiac electrophysiology.


Subject(s)
Artificial Intelligence , Electrophysiologic Techniques, Cardiac , Humans , Imaging, Three-Dimensional , Machine Learning
8.
Europace ; 23(12): 1892-1902, 2021 12 07.
Article in English | MEDLINE | ID: mdl-34477862

ABSTRACT

Cardiac arrhythmias are a leading cause of morbidity and mortality in the developed world. A common mechanism underlying many of these arrhythmias is re-entry, which may occur when native conduction pathways are disrupted, often by myocardial infarction. Presently, re-entrant arrhythmias are most commonly treated with antiarrhythmic drugs and myocardial ablation, although both treatment methods are associated with adverse side effects and limited efficacy. In recent years, significant advancements in the field of biomaterials science have spurred increased interest in the development of novel therapies that enable restoration of native conduction in damaged or diseased myocardium. In this review, we assess the current landscape of materials-based approaches to eliminating re-entrant arrhythmias. These approaches potentially pave the way for the eventual replacement of myocardial ablation as a preferred therapy for such pathologies.


Subject(s)
Catheter Ablation , Myocardial Infarction , Anti-Arrhythmia Agents , Arrhythmias, Cardiac/diagnosis , Arrhythmias, Cardiac/surgery , Catheter Ablation/adverse effects , Heart Rate , Humans , Myocardial Infarction/complications
9.
Artif Intell Med ; 118: 102135, 2021 08.
Article in English | MEDLINE | ID: mdl-34412835

ABSTRACT

We propose a novel convolutional neural network framework for mapping a multivariate input to a multivariate output. In particular, we implement our algorithm within the scope of 12-lead surface electrocardiogram (ECG) reconstruction from intracardiac electrograms (EGM) and vice versa. The goal of performing this task is to allow for improved point-of-care monitoring of patients with an implanted device to treat cardiac pathologies. We will achieve this goal with 12-lead ECG reconstruction and by providing a new diagnostic tool for classifying five different ECG types. The algorithm is evaluated on a dataset retroactively collected from 14 patients. Correlation coefficients calculated between the reconstructed and the actual ECG show that the proposed convolutional neural network model represents an efficient, accurate, and superior way to synthesize a 12-lead ECG when compared to previous methods. We can also achieve the same reconstruction accuracy with only one EGM lead as input. We also tested the model in a non-patient specific way and saw a reasonable correlation coefficient. The model was also executed in the reverse direction to produce EGM signals from a 12-lead ECG and found that the correlation was comparable to the forward direction. Lastly, we analyzed the features learned in the model and determined that the model learns an overcomplete basis of our 12-lead ECG space. We then use this basis of features to create a new diagnostic tool for classifying different ECG arrhythmia's on the MIT-BIH arrhythmia database with an average accuracy of 0.98.


Subject(s)
Electrophysiologic Techniques, Cardiac , Signal Processing, Computer-Assisted , Algorithms , Arrhythmias, Cardiac/diagnosis , Electrocardiography , Humans , Neural Networks, Computer
10.
J Cardiovasc Electrophysiol ; 32(3): 704-712, 2021 03.
Article in English | MEDLINE | ID: mdl-33476464

ABSTRACT

INTRODUCTION: Few studies have examined heat transfer and thermal injury on the epiesophageal surface during radiofrequency application, or compared the risk of esophageal thermal injury between standard and high-power, short-duration (HPSD) ablation. We studied the thermodynamics of HPSD and standard ablation at different tissue interfaces between the left atrium and esophagus, focusing on epiesophageal temperature changes and thermal injury. METHODS AND RESULTS: Fresh porcine heart and esophageal sections were secured to a custom holder and submerged in a temperature-controlled, circulating water bath. During ablation, thermistors recorded temperatures at the catheter tip-atrial interface, epiesophageal-atrial interface, and esophageal lumen. Samples were ablated in triplicate with the following parameters: contact force (15/25g), power (10/20/30 W standard; 40/45/50 W HPSD), and duration (10/20/30 s standard; 5/10/15 s HPSD). Epiesophageal and endoluminal temperature rises were greater in HPSD than in standard ablation (epiesophageal: 5.9 ± 5.6 vs. 2.2 ± 2.0°C, p < .01; endoluminal: 0.7 ± 0.5 vs. 0.4 ± 0.2°C, p < .01). Six of 30 HPSD ablations and 1 of 26 standard ablations caused esophageal injury. The delay between the peak epiesophageal and endoluminal temperatures was greater in HPSD than in standard ablation (24.2 ± 22.1 vs. 13.0 ± 11.0 s, p = .023). Likewise, the peak epiesophageal surface temperature differed more from the concurrent endoluminal temperature in HPSD ablation (5.1 ± 5.3 vs. 1.7 ± 2.0°C, p < .01). CONCLUSION: Endoluminal temperature underestimates epiesophageal surface temperature substantially during HPSD ablation. Visible epiesophageal injury was associated with a 2.2 ± 2.1°C rise in endoluminal temperature, corresponding to a 10.2 ± 6.5°C rise in epiesophageal temperature.


Subject(s)
Atrial Fibrillation , Catheter Ablation , Radiofrequency Ablation , Animals , Atrial Fibrillation/surgery , Catheter Ablation/adverse effects , Esophagus/diagnostic imaging , Esophagus/surgery , Swine , Temperature
11.
Pacing Clin Electrophysiol ; 43(6): 593-601, 2020 06.
Article in English | MEDLINE | ID: mdl-32333406

ABSTRACT

BACKGROUND: Pericardial access is complicated by two difficulties: confirming when the needle tip is in the pericardial space, and avoiding complications during access, such as inadvertently puncturing other organs. Conventional imaging tools are inadequate for addressing these difficulties, as they lack soft-tissue markers that could be used as guidance during access. A system that can both confirm access and avoid inadvertent organ injury is needed. METHODS: A 21G micropuncture needle was modified to include two small electrodes at the needle tip. With continuous bioimpedance monitoring from the electrodes, the needle was used to access the pericardium in porcine models (n  =  4). The needle was also visualized in vivo by using an electroanatomical map (n  =  2). Bioimpedance data from different tissues were analyzed retrospectively. RESULTS: Bioimpedance data collected from the subcutaneous space (992.8 ± 13.1 Ω), anterior mediastinum (972.2 ± 14.2 Ω), pericardial space (323.2 ± 17.1 Ω), mid-myocardium (349.7 ± 87.6 Ω), right ventricular cavity (235.0 ± 9.7 Ω), lung (1142.0 ± 172.0 Ω), liver (575.0 ± 52.6 Ω), and blood (177.5 ± 1.9 Ω) differed significantly by tissue type (P < .01). Phase data in the frequency domain correlated well with the needle being in the pericardial space. A simple threshold analysis effectively separated lung (threshold  =  1120.0 Ω) and blood (threshold  =  305.9 Ω) tissues from the other tissue types. CONCLUSIONS: Continuous bioimpedance monitoring from a modified micropuncture needle during pericardial access can be used to clearly differentiate tissues. Combined with traditional imaging modalities, this system allows for confirming access to the pericardial space while avoiding inadvertent puncture of other organs, creating a safer and more efficient needle-access procedure.


Subject(s)
Pericardium/surgery , Punctures/instrumentation , Punctures/methods , Animals , Electric Impedance , Equipment Design , Needles , Swine
12.
Sci Rep ; 10(1): 6252, 2020 Apr 07.
Article in English | MEDLINE | ID: mdl-32253377

ABSTRACT

An amendment to this paper has been published and can be accessed via a link at the top of the paper.

13.
Sci Rep ; 10(1): 2067, 2020 02 07.
Article in English | MEDLINE | ID: mdl-32034237

ABSTRACT

About 30% of patients with impaired cardiac function have ventricular dyssynchrony and seek cardiac resynchronization therapy (CRT). In this study, we demonstrate synchronized biventricular (BiV) pacing in a leadless fashion by implementing miniaturized and wirelessly powered pacemakers. With their flexible form factors, two pacemakers were implanted epicardially on the right and left ventricles of a porcine model and were inductively powered at 13.56 MHz and 40.68 MHz industrial, scientific, and medical (ISM) bands, respectively. The power consumption of these pacemakers is reduced to µW-level by a novel integrated circuit design, which considerably extends the maximum operating distance. Leadless BiV pacing is demonstrated for the first time in both open-chest and closed-chest porcine settings. The clinical outcomes associated with different interventricular delays are verified through electrophysiologic and hemodynamic responses. The closed-chest pacing only requires the external source power of 0.3 W and 0.8 W at 13.56 MHz and 40.68 MHz, respectively, which leads to specific absorption rates (SARs) 2-3 orders of magnitude lower than the safety regulation limit. This work serves as a basis for future wirelessly powered leadless pacemakers that address various cardiac resynchronization challenges.


Subject(s)
Cardiac Resynchronization Therapy Devices , Wireless Technology , Animals , Defibrillators, Implantable , Disease Models, Animal , Electric Power Supplies , Electrocardiography , Equipment Design , Female , Swine , Wireless Technology/instrumentation
14.
Heart Rhythm O2 ; 1(4): 290-296, 2020 Oct.
Article in English | MEDLINE | ID: mdl-34113883

ABSTRACT

BACKGROUND: Bipolar radiofrequency (RF) ablation strategies are increasingly used, mainly to target deep myocardial reentrant circuits responsible for ventricular tachycardia that cannot be extinguished with traditional unipolar RF ablation. Because this strategy is novel, factors that affect lesion geometry and steam pop formation require further investigation. OBJECTIVE: To assess the effect of contact force, power, and time on the resulting lesion geometry and the risk of steam pop formation during bipolar RF ablation of thick myocardial tissue. METHODS: A custom ex vivo bipolar ablation model was used to assess lesion formation. A combination of parallel and perpendicular configurations of ablation catheters was used to create lesions by varying force (20g, 30g, or 40g), power (30 or 40 W), and time (20, 30, 45, or 60 seconds). Lesion dimensions and the incidence of steam pops were recorded and then analyzed with binary logistic regression and multiple linear regression. RESULTS: In bipolar ablation, lesion transmurality was most affected by the amount of time RF energy was applied. Durations longer than 20 seconds resulted in lesions deeper than half the tissue thickness. Steam pop formation was more frequent in thinner tissue, at longer ablation times, and at higher powers. CONCLUSION: The parameters assessed in this ex vivo model could be used as guidelines for future in vivo work and clinical evaluation of interventricular septal bipolar ablation.

15.
Tex Heart Inst J ; 47(4): 265-270, 2020 08 01.
Article in English | MEDLINE | ID: mdl-33472218

ABSTRACT

Ethanol solubilizes cell membranes, making it useful for various ablation applications. We examined the effect of time and alcohol type on the extent of ablation, quantified as Euclidean distances between color coordinates. We obtained biopsy punch samples (diameter, 6 mm) of left atrial appendage, atrial, ventricular, and septal tissue from porcine hearts and placed them in transwell plates filled with ethanol or methanol for 10, 20, 30, 40, 50, or 60 min. Control samples were taken for each time point. At each time point, samples were collected, cut transversely, and photographed. With use of a custom MATLAB program, all images were analyzed in the CIELAB color space, which is more perceptually uniform than the red-green-blue color space. Euclidean distances were calculated from CIELAB coordinates. The mean and standard error of these distances were analyzed. Two-way analysis of variance was used to test for differences among time points, and 2-tailed t tests, for differences between the alcohol datasets at each time point. Generally, Euclidean distances differed significantly between all time points, except for those immediately adjacent, and methanol produced larger Euclidean distances than ethanol did. Some tissue showed a plateauing effect, potentially indicating transmurality. Mean Euclidean distances effectively indexed alcohol ablation in cardiac tissue. Furthermore, we found that methanol ablated tissue more effectively than ethanol did. With ethanol, the extent of ablation for atrial tissue was largest at 60 min. We conclude that to achieve full transmurality in clinical applications, ethanol must remain in contact with atrial tissue for at least one hour.


Subject(s)
Ablation Techniques/methods , Arrhythmias, Cardiac/therapy , Ethanol/pharmacology , Animals , Disease Models, Animal , Heart Atria , Heart Ventricles , Swine
16.
Circ Arrhythm Electrophysiol ; 12(8): e007256, 2019 08.
Article in English | MEDLINE | ID: mdl-31401852

ABSTRACT

BACKGROUND: Impaired myocardial conduction is the underlying mechanism for re-entrant arrhythmias. Carbon nanotube fibers (CNTfs) combine the mechanical properties of suture materials with the conductive properties of metals and may form a restorative solution to impaired myocardial conduction. METHODS: Acute open chest electrophysiology studies were performed in sheep (n=3). Radiofrequency ablation was used to create epicardial conduction delay after which CNTf and then silk suture controls were applied. CNTfs were surgically sewn across the right atrioventricular junction in rodents, and acute (n=3) and chronic (4-week, n=6) electrophysiology studies were performed. Rodent toxicity studies (n=10) were performed. Electrical analysis of the CNTf-myocardial interface was performed. RESULTS: In all cases, the large animal studies demonstrated improvement in conduction velocity using CNTf. The acute rodent model demonstrated ventricular preexcitation during sinus rhythm. All chronic cases demonstrated resumption of atrioventricular conduction, but these required atrial pacing. There was no gross or histopathologic evidence of toxicity. Ex vivo studies demonstrated contact impedance significantly lower than platinum iridium. CONCLUSIONS: Here, we show that in sheep, CNTfs sewn across epicardial scar acutely improve conduction. In addition, CNTf maintain conduction for 1 month after atrioventricular nodal ablation in the absence of inflammatory or toxic responses in rats but only in the paced condition. The CNTf/myocardial interface has such low impedance that CNTf can facilitate local, downstream myocardial activation. CNTf are conductive, biocompatible materials that restore electrical conduction in diseased myocardium, offering potential long-term restorative solutions in pathologies interrupting efficient electrical transduction in electrically excitable tissues.


Subject(s)
Arrhythmias, Cardiac/surgery , Atrioventricular Node/physiopathology , Carbon Fiber , Catheter Ablation/methods , Heart Atria/physiopathology , Myocardium/pathology , Nanotubes, Carbon , Animals , Arrhythmias, Cardiac/diagnosis , Arrhythmias, Cardiac/physiopathology , Atrioventricular Node/surgery , Disease Models, Animal , Electrocardiography , Female , Male , Sheep
17.
Annu Int Conf IEEE Eng Med Biol Soc ; 2018: 3434-3437, 2018 Jul.
Article in English | MEDLINE | ID: mdl-30441125

ABSTRACT

In this work, we report an energy-efficient switched capacitor based millimeter-scale pacemaker (5 mm ×7.5 mm) and a multi-receiver wireless energy transfer system operating at around 200 MHz, and use them in a proof-of-concept multi-site heart pacing study. Two pacemakers were placed on two beating Langendorff rodent heart models separately. By utilizing a single transmitter positioned 20-30 cm away, both Langendorff hearts captured the stimuli simultaneously and were electromechanically coupled. This study provides an insight for future energy-efficient and distributed cardiac pacemakers that can offer cardiac resynchronization therapies.


Subject(s)
Pacemaker, Artificial , Thoracic Surgical Procedures , Cardiac Resynchronization Therapy , Equipment Design , Heart
18.
J Cardiovasc Electrophysiol ; 29(11): 1588-1593, 2018 11.
Article in English | MEDLINE | ID: mdl-30203520

ABSTRACT

INTRODUCTION: Fifteen to thirty percent of patients with impaired cardiac function have ventricular dyssynchrony and warrant cardiac resynchronization therapy (CRT). While leadless pacemakers eliminate lead-related complications, their current form factor is limited to single-chamber pacing. In this study, we demonstrate the feasibility of multisite, simultaneous pacing using miniaturized pacing nodes powered through wireless power transfer (WPT). METHODS: A wireless energy transfer system was developed based on resonant coupling at approximately 200 MHz to power multiple pacing nodes. The pacing node comprises circuitry to efficiently convert the harvested energy to output stimuli. To validate the use of these pacing nodes, ex vivo studies were carried out on Langendorff rodent heart models (n = 4). To mimic biventricular pacing, two beating Langendorff rodent heart models, kept 10 cm apart, were paced using two distinct pacing nodes, each attached on the ventricular epicardial surface of a given heart. RESULTS: All ex vivo Langendorff heart models were successfully paced with a simple coil antenna at 2 to 3 cm from the pacing node. The coil was operated at 198 MHz and 0.3 W. Subsequently, simultaneous pacing of two Langendorff heart models 30 cm apart using an output power of 5 W was reliably demonstrated. CONCLUSION: WPT provides a feasible option for multisite, wireless cardiac pacing. While the current system remains limited in design, it offers support and a conceptual framework for future iterations and eventual clinical utility.


Subject(s)
Cardiac Pacing, Artificial/methods , Energy Transfer/physiology , Heart/physiology , Isolated Heart Preparation/methods , Wireless Technology , Animals , Feasibility Studies , Isolated Heart Preparation/instrumentation , Models, Animal , Rodentia , Wireless Technology/instrumentation
19.
J Cardiovasc Electrophysiol ; 28(12): 1492-1499, 2017 Dec.
Article in English | MEDLINE | ID: mdl-28833720

ABSTRACT

INTRODUCTION: Epicardial catheter ablation is increasingly used to treat arrhythmias with an epicardial component. Nevertheless, percutaneous epicardial access remains associated with a significant risk of major complications. Developing a technology capable of confirming proper placement within the pericardial space could decrease complication rates. The purpose of this study was to examine differences in bioimpedance among the pericardial space, anterior mediastinum, and right ventricle. METHODS: An ovine model (n = 3) was used in this proof-of-concept study. A decapolar catheter was used to collect bipolar impedance readings; data were collected between each of five electrode pairs of varying distances. Data were collected from three test regions: the pericardial space, anterior mediastinum, and right ventricle. A control region in the inferior vena cava was used to normalize the data from the test regions. Analysis of variance was used to test for differences among regions. RESULTS: A total of 10 impedance values were collected in each animal between each of the five electrode pairs in the three test regions (n = 340) and the control region (n = 145). The average normalized impedance values were significantly different among the pericardial space (1.760 ± 0.370), anterior mediastinum (3.209 ± 0.227), and right ventricle (1.024 ± 0.207; P < 0.0001). In post hoc testing, the differences between each pair of regions were significant, as well (P < 0.001 for all). CONCLUSION: Impedance values are significantly different among these three anatomical compartments. Therefore, impedance can be potentially used as a means to guide percutaneous epicardial access.


Subject(s)
Electric Impedance , Epicardial Mapping/methods , Mediastinum/diagnostic imaging , Pericardium/diagnostic imaging , Animals , Arrhythmias, Cardiac/diagnostic imaging , Arrhythmias, Cardiac/physiopathology , Arrhythmias, Cardiac/surgery , Catheter Ablation/methods , Heart Ventricles/diagnostic imaging , Heart Ventricles/physiopathology , Male , Mediastinum/physiopathology , Pericardium/physiopathology , Sheep