Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 2 de 2
Filter
Add more filters










Database
Language
Publication year range
1.
Anal Sci ; 23(3): 291-4, 2007 Mar.
Article in English | MEDLINE | ID: mdl-17372370

ABSTRACT

A PVC membrane sensor for the selective determination of mebendazole (MBZ) was fabricated. The sensor is based on an ion association of MBZ with silicotungstic acid (STA) as ion pair and bis(2-ethylhexyl)phthalate (BEP) as the plasticizing agent in a PVC matrix. The sensor showed a linear response for MBZ for a concentration range 1.0x10(-6)-5.0x10(-2) M with a Nernstian slope of 55.8 mV/decade (limit of detection 6.3x10(-7) M) in the pH range 4-7. It has a fast response time of <30 s. The sensor showed a very good selectivity for MBZ with respect to a large number of ions. The direct determination of MBZ in pharmaceutical formulations gave results that compare well with the data obtained from the standard method.


Subject(s)
Mebendazole/chemistry , Membranes, Artificial , Pharmaceutical Preparations/analysis , Anthelmintics/analysis , Hydrogen-Ion Concentration , Polyvinyl Chloride/chemistry , Silicates/chemistry , Time Factors , Tungsten Compounds/chemistry
2.
Anal Sci ; 22(10): 1333-7, 2006 Oct.
Article in English | MEDLINE | ID: mdl-17038772

ABSTRACT

A new PVC membrane ion selective electrode which is highly selective towards Ni(II) ions was constructed using a Schiff base containing a binaphthyl moiety as the ionophore. The sensor exhibited a good Nernstian response for nickel ions over the concentration range 1.0x10(-1)-5.0x10(-6) M with a lower limit of detection of 1.3x10(-6) M. It has a fast response time and can be used for a period of 4 months with a good reproducibility. The sensor is suitable for use in aqueous solutions in a wide pH range of 3.6-7.4 and works satisfactorily in the presence of 25% (v/v) methanol or ethanol. The sensor shows high selectivity to nickel ions over a wide variety of cations. It has been successfully used as an indicator electrode in the potentiometric titration of nickel ions against EDTA and also for the direct determination of nickel content in real samples: effluent samples, chocolates and hydrogenated oils.


Subject(s)
Ethylenediamines/chemistry , Nickel/chemistry , Calibration , Chemistry Techniques, Analytical/methods , Edetic Acid/chemistry , Electrodes , Ethanol/chemistry , Hydrogen-Ion Concentration , Ion-Selective Electrodes , Ions , Iontophoresis/instrumentation , Methanol/chemistry , Models, Chemical , Potentiometry
SELECTION OF CITATIONS
SEARCH DETAIL
...