Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 4 de 4
Filter
Add more filters










Database
Language
Publication year range
1.
J Air Waste Manag Assoc ; 65(4): 395-403, 2015 Apr.
Article in English | MEDLINE | ID: mdl-25947209

ABSTRACT

UNLABELLED: Recently, the U.S. Environmental Protection Agency (EPA) posted a ground-based optical remote sensing method on its Web site called Other Test Method (OTM) 10 for measuring fugitive gas emission flux from area sources such as closed landfills. The OTM 10 utilizes the vertical radial plume mapping (VRPM) technique to calculate fugitive gas emission mass rates based on measured wind speed profiles and path-integrated gas concentrations (PICs). This study evaluates the accuracy of the VRPM technique in measuring gas emission from animal waste treatment lagoons. A field trial was designed to evaluate the accuracy of the VRPM technique. Control releases of methane (CH4) were made from a 45 m×45 m floating perforated pipe network located on an irrigation pond that resembled typical treatment lagoon environments. The accuracy of the VRPM technique was expressed by the ratio of the calculated emission rates (QVRPM) to actual emission rates (Q). Under an ideal condition of having mean wind directions mostly normal to a downwind vertical plane, the average VRPM accuracy was 0.77±0.32. However, when mean wind direction was mostly not normal to the downwind vertical plane, the emission plume was not adequately captured resulting in lower accuracies. The accuracies of these nonideal wind conditions could be significantly improved if we relaxed the VRPM wind direction criteria and combined the emission rates determined from two adjacent downwind vertical planes surrounding the lagoon. With this modification, the VRPM accuracy improved to 0.97±0.44, whereas the number of valid data sets also increased from 113 to 186. IMPLICATIONS: The need for developing accurate and feasible measuring techniques for fugitive gas emission from animal waste lagoons is vital for livestock gas inventories and implementation of mitigation strategies. This field lagoon gas emission study demonstrated that the EPA's vertical radial plume mapping (VRPM) technique can be used to accurately measure lagoon gas emission with two downwind vertical concentration planes surrounding the lagoon.


Subject(s)
Air Pollutants/chemistry , Environmental Monitoring/methods , Methane/chemistry , Waste Disposal, Fluid/methods , Agricultural Irrigation , Animals , Geographic Mapping , Uncertainty , United States , Wind
2.
J Environ Qual ; 43(4): 1111-8, 2014 Jul.
Article in English | MEDLINE | ID: mdl-25603059

ABSTRACT

This study evaluated the impact of gas concentration and wind sensor locations on the accuracy of measuring gas emission rates from a lagoon environment using the backward Lagrangian stochastic (bLS) inverse-dispersion technique. Path-integrated concentrations (PICs) and three-dimensional (3D) wind vector data were collected at different locations within the lagoon landscape. A floating 45 m × 45 m perforated pipe network on an irrigation pond was used as a synthetic distributed emission source for the controlled release of methane. A total of 961 15-min datasets were collected under different atmospheric stability conditions over a 2-yr period. The PIC location had a significant impact on the accuracy of the bLS technique. The location of the 3D sonic anemometer was generally not a factor for the measured accuracies with the PIC positioned on the downwind berm. The PICs across the middle of the pond consistently produced the lowest accuracy with any of the 3D anemometer locations (<69% accuracy). The PICs located on the downwind berm consistently yielded the best bLS accuracy regardless of whether the 3D sonic anemometer was located on the upwind, side, or downwind berm (accuracies ranged from 79 to 108%). The accuracies of the emission measurements with the berm PIC-berm 3D setting were statistically similar to that found in a more ideal homogeneous grass field. Considering the practical difficulties of setting up equipment and the accuracies associated with various sensor locations, we recommend that wind and concentration sensors be located on the downwind berm.

3.
Article in English | MEDLINE | ID: mdl-20390880

ABSTRACT

Oxygen transfer efficiencies of various components of the marsh-pond-marsh (M-P-M) and marsh-floating bed-marsh (M-FB-M) wetlands treating swine wastewater were determined by performing oxygen mass balance around the wetlands. Biological oxygen demand (BOD) and total nitrogen (TN) loading and escaping rates from each wetland were used to calculate carbonaceous and nitrogenous oxygen demands. Ammonia emissions were measured using a wind tunnel. Oxygen transfer efficiencies of the aerated ponds were estimated by conducting the ASCE standard oxygen transfer test in a tank using the same aeration device. Covering pond water surface with the floating bed slightly decreased oxygen transfer efficiency. The diffused membrane aeration (26.7 kg O2 ha-1 d-1) of M-P-M was surprisingly not as effective as plant aeration in the marsh (38.9 to 42.0 kg O2 ha-1 d-1). This unusually low oxygen transfer efficiency of the diffused aeration was attributed to its low submergence depth of 0.8 m compared to typical depth of 4.5 m. The wetlands consisting entirely of marsh removed similar amounts of C and N without investing additional equipment and energy costs of aerating ponds in the middle of wetlands.


Subject(s)
Environmental Restoration and Remediation/methods , Oxygen/chemistry , Waste Disposal, Fluid/methods , Wetlands , Ammonia/chemistry , Animals , Swine
4.
Article in English | MEDLINE | ID: mdl-19827493

ABSTRACT

Improved characterization of distributed emission sources of greenhouse gases such as methane from concentrated animal feeding operations require more accurate methods. One promising method is recently used by the USEPA. It employs a vertical radial plume mapping (VRPM) algorithm using optical remote sensing techniques. We evaluated this method to estimate emission rates from simulated distributed methane sources. A scanning open-path tunable diode laser was used to collect path-integrated concentrations (PICs) along different optical paths on a vertical plane downwind of controlled methane releases. Each cycle consists of 3 ground-level PICs and 2 above ground PICs. Three- to 10-cycle moving averages were used to reconstruct mass equivalent concentration plum maps on the vertical plane. The VRPM algorithm estimated emission rates of methane along with meteorological and PIC data collected concomitantly under different atmospheric stability conditions. The derived emission rates compared well with actual released rates irrespective of atmospheric stability conditions. The maximum error was 22 percent when 3-cycle moving average PICs were used; however, it decreased to 11% when 10-cycle moving average PICs were used. Our validation results suggest that this new VRPM method may be used for improved estimations of greenhouse gas emission from a variety of agricultural sources.


Subject(s)
Agriculture , Air Pollutants/analysis , Environmental Monitoring/methods , Greenhouse Effect , Air Movements , Algorithms , Animals , Animals, Domestic/metabolism , Methane/analysis , United States , United States Environmental Protection Agency
SELECTION OF CITATIONS
SEARCH DETAIL
...