Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 3 de 3
Filter
Add more filters










Database
Language
Publication year range
1.
J Aerosol Med Pulm Drug Deliv ; 35(3): 146-153, 2022 06.
Article in English | MEDLINE | ID: mdl-34647795

ABSTRACT

Background: Inhaled drug delivery can be limited by heterogeneous dose distribution. An additive that would disperse drug over the internal surfaces of the lung after aerosol deposition could improve dosing uniformity and increase the treated area. Our previous studies demonstrated that surfactant additives can produce surface tension-driven (Marangoni) flows that effectively dispersed aerosol-delivered drugs over mucus surfaces. Here we sought to determine whether the addition of a surfactant would increase transport of an aerosol between lung regions and also improve dosing uniformity in human lungs. Methods: We compared the deposition and postdeposition dispersion of surfactant (10 mg/mL dipalmitoylphosphatidylcholine; DPPC) and saline-based liquid aerosols, admixed with Technetium 99m (Tc99m) diethylenetriaminepentaacetic acid, using gamma scintigraphy. Deposition images were obtained ex vivo in eight pairs of ventilated human lungs. The trachea was intubated and the mainstem bronchi were alternately clamped so that saline was delivered to one lung and then DPPC to the other (sides alternated). The lungs were continually imaged for 15 minutes during delivery. We assessed transport of the deposited aerosol by quantifying the percentage of Tc99m in each of four lung quadrants over time. We quantified dose uniformity within each lung quadrant by measuring the coefficient of variation (CV = standard deviation of the pixel associated radioactive counts/mean of the counts within each quadrant). Results: There was no change in the percentage of Tc99m in each quadrant over time, indicating no improvement in transport with the addition of the surfactant. The addition of surfactant was associated with a statistically significant decrease in CV in the lower inner lung quadrant at each of the three time points, indicating an improvement in dosing uniformity. Conclusion: These preliminary results indicate the possible utility of adding surfactant to aerosols to improve drug distribution uniformity to lower inner lung regions.


Subject(s)
Pulmonary Surfactants , Surface-Active Agents , Administration, Inhalation , Aerosols , Excipients , Humans , Lung , Nebulizers and Vaporizers , Technetium Tc 99m Pentetate
2.
Pediatr Pulmonol ; 54(8): 1319-1325, 2019 08.
Article in English | MEDLINE | ID: mdl-30932345

ABSTRACT

AIM: Nasal cannulas are used to provide oxygen support for infants and have been considered as a means for delivering aerosols to the lungs. To measure mucociliary clearance in the lungs of infants with congenital heart defects, we delivered radiopharmaceutical aerosols via a nasal cannula. Here we report on the pulmonary and nasal deposition of these aerosols. METHOD: A total of 18 infants (median age = 26 days; quartiles = 11-74 days) performed clearance measurements soon before or after corrective cardiac surgery. The regional aerosol deposition was assessed using gamma camera imaging. RESULTS: Cannula flow rate significantly affected pulmonary dosing. Flow rates useful for oxygen support were associated with low pulmonary deposition (2 L/min; mean, 4.5% of deposited dose; range, 2%-9%; n = 7) and high nasal deposition. Much lower cannula flow rates increased the pulmonary deposition (0.2 L/min; mean, 33.5% of deposited dose; range, 15%-51%; n = 5; P = 0.005 vs 2 L/min). The ratio of nose/lung dosing was approximately 26:1 at 2 L/min and 2:1 at 0.2 L/min. Bench studies demonstrated cannula output rates of 10.2 ± 1.7% (2 L/min) and 3.3 ± 0.4% (0.2 L/min) of the loaded nebulizer dose during a 2-minute delivery. Combining in vitro and in vivo results, we estimate that 0.46% of the loaded nebulizer dose reaches the lungs at 2 L/min vs 1.10% at 0.2 L/min during a 2-minute delivery. CONCLUSION: With the delivery system used here, pulmonary aerosol delivery via nasal cannula was very inefficient at the flow rates required to provide oxygen support. Even at low flows, nasal deposition was substantial and local toxicity must be considered.


Subject(s)
Cannula , Nebulizers and Vaporizers , Oxygen/administration & dosage , Administration, Intranasal , Aerosols , Female , Heart Defects, Congenital/metabolism , Heart Defects, Congenital/therapy , Humans , Infant , Infant, Newborn , Lung/metabolism , Male , Nasal Mucosa/metabolism , Particle Size
3.
J Aerosol Med Pulm Drug Deliv ; 32(4): 242-249, 2019 08.
Article in English | MEDLINE | ID: mdl-30969149

ABSTRACT

Background: Nuclear imaging biomarkers illustrate unique aspects of lung physiology and are useful for assessing therapeutic effects in cystic fibrosis (CF) lung disease. We have developed a multiprobe method to simultaneously measure mucociliary clearance (MCC) and paracellular absorption (ABS). MCC is a direct measure of mucus clearance. ABS has been related to airway surface liquid (ASL) absorption through previous in vitro studies. Methods: We describe baseline factors affecting MCC and ABS using data from a retrospective baseline group (n = 22) and the response of the measures to inhaled 7% hypertonic saline (HS) and dry powder mannitol using data from a prospective response group (n = 7). A retrospective healthy control group (n = 15) is also described. The baseline and control groups performed single measurements of MCC/ABS. The response group performed baseline measurements of MCC/ABS and measurements after each intervention. Results: ABS was correlated (Spearman's ρ = 0.51, p = 0.06) to sweat chloride, a systemic measure of cystic fibrosis transmembrane conductance regulator (CFTR) function, whereas MCC was not. Baseline MCC was depressed after Pseudomonas aeruginosa infection as we have previously described. MCC provided a more sensitive indication of therapeutic effect and indicated improved clearance with mannitol compared with HS. Conclusion: MCC provides a useful and well-established means of testing therapies directed at improving mucus clearance in the lung. ABS may provide a means of detecting local changes in ASL absorption and CFTR function in the lung. Both are useful tools for studying the key aspects of CF lung pathophysiology (ASL hyperabsorption and MCC depression) that link the basic genetic defects of CF to disease manifestations in the lung.


Subject(s)
Cystic Fibrosis/diagnostic imaging , Lung/diagnostic imaging , Mucociliary Clearance , Pseudomonas Infections/diagnosis , Administration, Inhalation , Adolescent , Adult , Biomarkers/metabolism , Case-Control Studies , Child , Cystic Fibrosis/physiopathology , Cystic Fibrosis Transmembrane Conductance Regulator/metabolism , Female , Humans , Lung/physiopathology , Male , Mannitol/administration & dosage , Prospective Studies , Retrospective Studies , Saline Solution, Hypertonic/administration & dosage , Young Adult
SELECTION OF CITATIONS
SEARCH DETAIL
...