Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 4 de 4
Filter
Add more filters










Database
Language
Publication year range
2.
Sci Rep ; 13(1): 10799, 2023 Jul 04.
Article in English | MEDLINE | ID: mdl-37402874

ABSTRACT

This paper experimentally demonstrates a crossed reaction of pure and hybrid graphene oxide (GO)/tantalum dioxide (TaO2) as a volatile organic compound (VOC) absorber in a guided mode resonance (GMR) sensing platform. The proposed GMR platform has a porous TaO2 film as the main guiding layer, allowing for more molecular adsorption and enhanced sensitivity. GO is applied on top as an additional VOC absorber to increase the selectivity. The hybrid sensing mechanism is introduced by varying the concentration of the GO aqueous solution. The experimental results show that the pure TaO2-GMR has a high tendency to adsorb most of the tested VOC molecules, with the resonance wavelength shifting accordingly to the physical properties of the VOCs (molecular weight, vapor pressure, etc). The largest signal appears in the large molecule such as toluene, and its sensitivity is gradually reduced in the hybrid sensors. At the optimum GO concentration of 3 mg/mL, the hybrid GO/TaO2 -GMR is more sensitive to methanol, while the pure GO sensor coated with GO at 5 mg/mL is highly selective to ammonia. The sensing mechanisms are verified using the distribution function theory (DFT) to simulate the molecular absorption, along with the measured functional groups measured on the sensor surface by the Fourier transform infrared spectroscopy (FTIR). The crossed reaction of these sensors is further analyzed by means of machine learning, specifically the principal component analysis (PCA) method and decision tree algorithm. The results show that this sensor is a promising candidate for quantitative and qualitative VOCs detection in sensor array platform.

3.
Inorg Chem ; 57(9): 5413-5419, 2018 May 07.
Article in English | MEDLINE | ID: mdl-29658713

ABSTRACT

Higher OH concentration is identified in tetragonal barium titanate (BaTiO3) nanorods synthesized by a hydrothermal method with a 10 vol % ethylene glycol solvent (Inada, M.; et al. Ceram. Int. 2015, 41, 5581-5587). This is apparently inconsistent with the known fact that higher OH concentration in the conventional hydrothermal synthesis makes pseudocubic BaTiO3 nanocrystals more stable than the tetragonal one. To understand where and how the introduced OH anions are located and behave in the nanocrystals, we applied ab initio analysis to several possible microscopic geometries of OH locations, confirming the relative stability of the tetragonal distortion over the pseudocubic one because of the preference of trans-type configurations of OH anions. We also performed Fourier transform infrared and X-ray diffraction analysis, all being consistent with the microscopic picture established by the ab initio geometrical optimizations.

4.
Lab Chip ; 12(1): 133-8, 2012 Jan 07.
Article in English | MEDLINE | ID: mdl-22072313

ABSTRACT

Recently, we have demonstrated that DNA hybridization using acoustic streaming induced by two piezoelectric transducers provides higher DNA hybridization efficiency than the conventional method. In this work, we refine acoustic streaming system for DNA hybridization by inserting an additional piezoelectric transducer and redesigning the locations of the transducers. The Comsol® Multiphysics was used to design and simulate the velocity field generated by the piezoelectric agitation. The simulated velocity vector followed a spiral vortex flow field with an average direction outward from the center of the transducers. These vortices caused the lower signal intensity in the middle of the microarray for the two-piezoelectric disk design. On the contrary, the problem almost disappeared in the three-piezoelectric-disk system. The optimum condition for controlling the piezoelectric was obtained from the dye experiments with different activation settings for the transducers. The best setting was to activate the side disks and middle disk alternatively with 1 second activating time and 3 second non-activating time for both sets of transducers. DNA hybridization using microarrays for the malaria parasite Plasmodium falciparum from the optimized process yielded a three-fold enhancement of the signal compared to the conventional method. Moreover, a greater number of spots passed quality control in the optimized device, which could greatly improve biological interpretation of DNA hybridization data.


Subject(s)
Acoustics/instrumentation , Nucleic Acid Hybridization/methods , Oligonucleotide Array Sequence Analysis/instrumentation , Transducers , Carbocyanines/chemistry , DNA Probes , DNA, Protozoan/chemistry , DNA, Protozoan/genetics , Finite Element Analysis , Models, Molecular , Oligonucleotide Array Sequence Analysis/methods , Plasmodium falciparum/genetics , Signal Processing, Computer-Assisted
SELECTION OF CITATIONS
SEARCH DETAIL
...