Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 328
Filter
1.
Clin Res Cardiol ; 2024 May 13.
Article in English | MEDLINE | ID: mdl-38740722

ABSTRACT

BACKGROUND: The ISAR-REACT 5 trial compared the efficacy and safety of ticagrelor and prasugrel in patients with ACS managed invasively. The present study sought to investigate the impact of ticagrelor and prasugrel on the incidence and pattern of urgent revascularization in acute coronary syndromes (ACS) patients undergoing percutaneous coronary intervention (PCI). METHODS AND RESULTS: This post-hoc analysis of the ISAR-REACT 5 trial included all ACS patients who underwent PCI. The primary endpoint for this analysis was the incidence of urgent revascularization at 12-month follow-up. Secondary outcome was the pattern of urgent revascularization procedures (namely, urgent target vessel/non-target vessel revascularization - TVR/NTVR). Among 3,377 ACS patients who underwent PCI, 1,676 were assigned to ticagrelor and 1,701 to prasugrel before PCI. After 12 months, the incidence of urgent revascularization was higher among patients assigned to ticagrelor as compared to prasugrel (6.8% vs. 5.2%; hazard ratio [HR] = 1.32, 95% confidence interval [CI] 1.00-1.75; p = 0.051), mostly attributable to significantly more urgent NTVR in the ticagrelor group (3.8% vs. 2.4%; HR = 1.62 [1.09-2.41]; p = 0.017). The risk of urgent TVR did not differ between treatment groups (3.3% vs. 3.0%; HR = 1.13 [0.77-1.65]; p = 0.546). CONCLUSIONS: In ACS patients treated with PCI, the cumulative rate of urgent revascularizations after 12 months is higher with ticagrelor compared to prasugrel, due to a significant increase in urgent revascularizations involving remote coronary vessels.

2.
Eur J Clin Invest ; : e14241, 2024 May 20.
Article in English | MEDLINE | ID: mdl-38767226

ABSTRACT

BACKGROUND: Transcatheter aortic valve implantation (TAVI) is increasingly being used in younger patients and those with lower peri-procedural risk, meaning more patients will live long enough to experience structural valve deterioration (SVD) of the bioprosthesis, indicating repeated TAVI. Experience of repeated TAVI-transcatheter heart valve (THV) implantation into an index THV is limited. This registry aims to assess the peri-procedural and short-term safety, efficacy and durability of repeated TAVI. METHODS: The ReTAVI Prospective observational registry is an investigator-initiated, multicentre, international, prospective registry of patients undergoing repeated TAVI using balloon-expandable SAPIEN prosthesis to evaluate procedural and short-term safety, efficacy and durability as well as anatomical and procedural factors associated with optimal results. The registry will enrol at least 150 patients across 60 high-volume centres. Patients must be ≥18 years old, have had procedural success with their first TAVI, have index THV device failure, intend to undergo repeated TAVI and be considered suitable candidates by their local Heart Team. All patients will undergo a 30-day and 12-month follow-up. The estimated study completion is 2025. CONCLUSIONS: The registry will collect pre-, peri-, postoperative and 12-months data on patients undergoing repeated TAVI procedures with THVs for failure of the index THV and determine VARC-3-defined efficacy and safety at 30 days and functional outcome at 12 months. The registry will expand existing data sets and identify patient characteristics/indicators related to complications and clinical benefits for patients with symptomatic severe calcific degenerative aortic stenosis.

3.
EuroIntervention ; 20(10): e669-e680, 2024 May 20.
Article in English | MEDLINE | ID: mdl-38776143

ABSTRACT

BACKGROUND: Compared with thin-strut durable-polymer drug-eluting stents (DP-DES), ultrathin-strut biodegradable-polymer sirolimus-eluting stents (BP-SES) improve stent-related clinical outcomes in patients undergoing percutaneous coronary intervention (PCI). Reduced stent strut thickness is hypothesised to underlie these benefits, but this conjecture remains unproven. AIMS: We aimed to assess the impact of strut thickness on stent healing and clinical outcomes between ultrathin-strut and thin-strut BP-SES. METHODS: First, we performed a preclinical study of 8 rabbits implanted with non-overlapping thin-strut (diameter/thickness 3.5 mm/80 µm) and ultrathin-strut (diameter/thickness 3.0 mm/60 µm) BP-SES in the infrarenal aorta. On day 7, the rabbits underwent intravascular near-infrared fluorescence optical coherence tomography (NIRF-OCT) molecular-structural imaging of fibrin deposition and stent tissue coverage, followed by histopathological analysis. Second, we conducted an individual data pooled analysis of patients enrolled in the BIOSCIENCE and BIOSTEMI randomised PCI trials treated with ultrathin-strut (n=282) or thin-strut (n=222) BP-SES. The primary endpoint was target lesion failure (TLF) at 1-year follow-up, with a landmark analysis at 30 days. RESULTS: NIRF-OCT image analyses revealed that ultrathin-strut and thin-strut BP-SES exhibited similar stent fibrin deposition (p=0.49) and percentage of uncovered stent struts (p=0.63). Histopathological assessments corroÂborated these findings. In 504 pooled randomised trial patients, TLF rates were similar for those treated with ultrathin-strut or thin-strut BP-SES at 30-day (2.5% vs 1.8%; p=0.62) and 1-year follow-up (4.3% vs 4.7%; p=0.88). CONCLUSIONS: Ultrathin-strut and thin-strut BP-SES demonstrate similar early arterial healing profiles and 30-day and 1-year clinical outcomes.


Subject(s)
Drug-Eluting Stents , Percutaneous Coronary Intervention , Sirolimus , Tomography, Optical Coherence , Animals , Rabbits , Percutaneous Coronary Intervention/instrumentation , Percutaneous Coronary Intervention/methods , Humans , Sirolimus/therapeutic use , Sirolimus/administration & dosage , Sirolimus/pharmacology , Treatment Outcome , Prosthesis Design , Coronary Artery Disease/therapy , Coronary Artery Disease/diagnostic imaging , Male , Absorbable Implants , Female , Wound Healing
4.
Struct Heart ; 8(3): 100282, 2024 May.
Article in English | MEDLINE | ID: mdl-38799808

ABSTRACT

Background: The interplay between the right ventricle and the pulmonary artery, known as right ventricular to pulmonary artery (RV-PA) coupling, is crucial for assessing right ventricular systolic function against the afterload from the pulmonary circulation. Pulmonary artery pressure levels are ideally measured by right heart catheterization. Yet, echocardiography represents the most utilized method for evaluating pulmonary artery pressure levels, albeit with limitations in accuracy. This study therefore aims to evaluate the prognostic significance of right ventricular to pulmonary artery (RV-PA) coupling expressed as tricuspid annular plane systolic excursion (TAPSE) related to systolic pulmonary artery pressure (sPAP) levels measured by right heart catheterization (TAPSE/sPAPinvasive) or estimated by transthoracic echocardiography (TAPSE/sPAPechocardiography) in patients with severe aortic stenosis undergoing transcatheter aortic valve replacement (TAVR). Methods: Using data from a bicentric registry, this study compares TAPSE/sPAPinvasive vs. TAPSE/sPAPechocardiography in predicting 1-year all-cause mortality after TAVR. Results: Among 333 patients with complete echocardiography and right heart catheterization data obtained before TAVR, their mean age was 79.8 ± 6.74 years, 39.6% were female, and general 1-year survival was 89.8%. sPAPinvasive and sPAPechocardiography showed only moderate correlation (Pearson correlation coefficient R: 0.53, p value: <0.0001). TAPSE/sPAPinvasive was superior to TAPSE/sPAPechocardiography in predicting 1-year all-cause mortality after TAVR (area under the curve: 0.662 vs. 0.569, p value: 0.025). Patients with reduced TAPSE/sPAPinvasive levels (< 0.365 mm/mmHg) evidenced significantly lower 1-year survival rates than patients with preserved TAPSE/sPAPinvasive levels (81.8 vs. 93.6%, p value: 0.001; hazard ratio for 1-year mortality: 3.09 [95% confidence interval: 1.55-6.17]). Echocardiographic follow-up data revealed that patients with reduced RV-PA coupling suffer from persistent right ventricular dysfunction (TAPSE: 16.6 ± 4.05 mm vs. 21.6 ± 4.81 mm in patients with preserved RV-PA coupling) and severe tricuspid regurgitation (diagnosed in 19.7 vs. 6.58% in patients with preserved RV-PA coupling). Conclusions: RV-PA coupling expressed as TAPSE/sPAPinvasive can refine stratification of severe aortic stenosis patients into low-risk and high-risk cohorts for mortality after TAVR. Moreover, it can help to anticipate persistent extra-aortic valve cardiac damage, which will demand further treatment.

5.
EuroIntervention ; 20(6): e363-e375, 2024 03 18.
Article in English | MEDLINE | ID: mdl-38506737

ABSTRACT

BACKGROUND: There is a lack of comparative data on transcatheter aortic valve implantation (TAVI) in degenerated surgical prostheses (valve-in-valve [ViV]). AIMS: We sought to compare outcomes of using two self-expanding transcatheter heart valve (THV) systems for ViV. METHODS: In this retrospective multicentre registry, we included consecutive patients undergoing transfemoral ViV using either the ACURATE neo/neo2 (ACURATE group) or the Evolut R/PRO/PRO+ (EVOLUT group). The primary outcome measure was technical success according to Valve Academic Research Consortium (VARC)-3. Secondary outcomes were 30-day all-cause mortality, device success (VARC-3), coronary obstruction (CO) requiring intervention, rates of severe prosthesis-patient mismatch (PPM), and aortic regurgitation (AR) ≥moderate. Comparisons were made after 1:1 propensity score matching. RESULTS: The study cohort comprised 835 patients from 20 centres (ACURATE n=251; EVOLUT n=584). In the matched cohort (n=468), technical success (ACURATE 92.7% vs EVOLUT 88.9%; p=0.20) and device success (69.7% vs 73.9%; p=0.36) as well as 30-day mortality (2.8% vs 1.6%; p=0.392) were similar between the two groups. The mean gradients and rates of severe PPM, AR ≥moderate, or CO did not differ between the groups. Technical and device success were higher for the ACURATE platform among patients with a true inner diameter (ID) >19 mm, whereas a true ID ≤19 mm was associated with higher device success - but not technical success - among Evolut recipients. CONCLUSIONS: ViV TAVI using either ACURATE or Evolut THVs showed similar procedural outcomes. However, a true ID >19 mm was associated with higher device success among ACURATE recipients, whereas in patients with a true ID ≤19 mm, device success was higher when using Evolut.


Subject(s)
Aortic Valve Insufficiency , Bioprosthesis , Coronary Occlusion , Transcatheter Aortic Valve Replacement , Humans , Catheters , Aortic Valve Insufficiency/etiology , Aortic Valve Insufficiency/surgery , Heart Valves , Registries , Transcatheter Aortic Valve Replacement/adverse effects
7.
J Biomech ; 164: 111988, 2024 Feb.
Article in English | MEDLINE | ID: mdl-38364489

ABSTRACT

The aim of this study is to qualitatively characterize the in vivo chronic scaffolding force of the Magmaris® Resorbable Magnesium Scaffold (RMS). This important parameter of scaffolds must be balanced between sufficient radial support during the healing period of the vessel and avoidance of long-term vessel caging. A finite element model was established using preclinical animal data and used to predict the device diameter and scaffolding force up to 90 days after implantation. To account for scaffold resorption, it included backbone degradation as well as formation of discontinuities as observed in vivo. The predictions of the model regarding acute recoil and chronic development of the device diameter were in good agreement with the preclinical data, supporting the validity of the model. It was found that after 28 and 90 days, the Magmaris® RMS retained 90 % and 47 % of its initial scaffolding force, respectively. The reduction in scaffolding force was mainly driven by discontinuities in the meandering segments. Finite element analysis combined with preclinical data is a reliable method to characterize the chronic scaffolding force.


Subject(s)
Coronary Artery Disease , Drug-Eluting Stents , Animals , Absorbable Implants , Magnesium , Treatment Outcome , Prosthesis Design
8.
Arterioscler Thromb Vasc Biol ; 44(4): 898-914, 2024 Apr.
Article in English | MEDLINE | ID: mdl-38328934

ABSTRACT

BACKGROUND: Smooth muscle cells (SMCs), which make up the medial layer of arteries, are key cell types involved in cardiovascular disease, the leading cause of mortality and morbidity worldwide. In response to microenvironment alterations, SMCs dedifferentiate from a contractile to a synthetic phenotype characterized by an increased proliferation, migration, production of ECM (extracellular matrix) components, and decreased expression of SMC-specific contractile markers. These phenotypic changes result in vascular remodeling and contribute to the pathogenesis of cardiovascular disease, including coronary artery disease, stroke, hypertension, and aortic aneurysms. Here, we aim to identify the genetic variants that regulate ECM secretion in SMCs and predict the causal proteins associated with vascular disease-related loci identified in genome-wide association studies. METHODS: Using human aortic SMCs from 123 multiancestry healthy heart transplant donors, we collected the serum-free media in which the cells were cultured for 24 hours and conducted liquid chromatography-tandem mass spectrometry-based proteomic analysis of the conditioned media. RESULTS: We measured the abundance of 270 ECM and related proteins. Next, we performed protein quantitative trait locus mapping and identified 20 loci associated with secreted protein abundance in SMCs. We functionally annotated these loci using a colocalization approach. This approach prioritized the genetic variant rs6739323-A at the 2p22.3 locus, which is associated with lower expression of LTBP1 (latent-transforming growth factor beta-binding protein 1) in SMCs and atherosclerosis-prone areas of the aorta, and increased risk for SMC calcification. We found that LTBP1 expression is abundant in SMCs, and its expression at mRNA and protein levels was reduced in unstable and advanced atherosclerotic plaque lesions. CONCLUSIONS: Our results unravel the SMC proteome signature associated with vascular disorders, which may help identify potential therapeutic targets to accelerate the pathway to translation.


Subject(s)
Atherosclerosis , Cardiovascular Diseases , Humans , Cardiovascular Diseases/metabolism , Genome-Wide Association Study , Proteomics , Muscle, Smooth, Vascular/metabolism , Aorta/metabolism , Atherosclerosis/pathology , Myocytes, Smooth Muscle/metabolism , Cells, Cultured
9.
Am J Cardiol ; 216: 19-26, 2024 Apr 01.
Article in English | MEDLINE | ID: mdl-38336081

ABSTRACT

The association between uric acid (UA) and long-term mortality in patients with coronary artery disease is poorly investigated. We assessed the association between UA and 10-year mortality after percutaneous coronary intervention (PCI) in 3,998 patients who underwent PCI. Patients were categorized in groups according to UA tertiles: tertile 1 (UA <5.80 mg/100 ml, n = 1,347), tertile 2 (UA 5.80 to 7.04 mg/100 ml, n = 1,340), and tertile 3 (UA >7.94 mg/100 ml, n = 1,311). The primary outcome was 10-year all-cause mortality. All-cause deaths occurred in 1,200 patients: 320 deaths (26.5%) in patients with UA in the first tertile, 325 deaths (26.9%) in patients with UA in the second tertile, and 555 deaths (46.0%) in patients with UA in the third tertile (adjusted hazard ratio 1.22, 95% confidence interval 1.17 to 1.27, p <0.001) for 1 mg/100 ml increment in UA level. Cardiac deaths occurred in 748 patients: 194 deaths (16.5%) in patients with UA in the first tertile, 202 deaths (17.0%) in patients with UA in the second tertile, and 352 deaths (29.7%) in patients with UA in the third tertile (adjusted hazard ratio 1.24 [1.17 to 1.32], p <0.001) for 1 mg/100 ml increment in the UA level. The 10-year rates of target lesion revascularization, target vessel revascularization, or nontarget vessel revascularization did not differ significantly according to the UA level. In conclusion, in patients with coronary artery disease treated with PCI, increased UA level was associated with higher 10-year mortality. Increased UA level was not associated with the progression of atherosclerosis in nontreated coronary vessels or progression of intimal hyperplasia in stented lesions requiring intervention.


Subject(s)
Coronary Artery Disease , Percutaneous Coronary Intervention , Humans , Coronary Artery Disease/complications , Follow-Up Studies , Uric Acid , Percutaneous Coronary Intervention/adverse effects , Proportional Hazards Models , Treatment Outcome , Risk Factors
10.
Article in English | MEDLINE | ID: mdl-38262740

ABSTRACT

BACKGROUND AND AIMS: To develop a suite of quality indicators (QIs) for the evaluation of the care and outcomes for adults undergoing transcatheter aortic valve intervention (TAVI). METHODS: We followed the European Society of Cardiology (ESC) methodology for the development of QIs. Key domains were identified by constructing a conceptual framework for the delivery of TAVI care. A list of candidate QIs were developed by conducting a systematic review of the literature. A modified Delphi method was then used to select the final set of QIs. Finally, we mapped the QIs to the EuroHeart Data Standards for TAVI to ascertain the extent to which the EuroHeart TAVI registry captures information to calculate the QIs. RESULTS: We formed an international group of experts in quality improvement and TAVI, including representatives from the European Association of Percutaneous Cardiovascular Interventions, the European Association of Cardiovascular Imaging and the Association of Cardiovascular Nursing & Allied Professions. In total, 27 QIs were selected across eight domains of TAVI care, comprising 22 main (81%) and five secondary (19%) QIs. Of these, 19/27 (70%) are now being utilised in the EuroHeart TAVI registry. CONCLUSION: We present the 2023 ESC QIs for TAVI, developed using a standard methodology and in collaboration with ESC Associations. The EuroHeart TAVI registry allows calculation of the majority of the QIs, which may be used for benchmarking care and quality improvement initiatives.

11.
Eur J Clin Invest ; 54(6): e14173, 2024 Jun.
Article in English | MEDLINE | ID: mdl-38264959

ABSTRACT

BACKGROUND: The association of aspirin loading with the risk of coronary no-reflow (CNR) after percutaneous coronary intervention (PCI) in patients with acute myocardial infarction (AMI) has not been investigated. We assessed the association of aspirin loading before PCI with CNR in patients with AMI. MATERIALS AND METHODS: This study included 3100 patients with AMI undergoing PCI. Of them, 2812 patients received aspirin loading (a single oral [or chewed] or intravenous dose of 150-300 mg) and 288 patients did not receive aspirin loading before PCI. The primary endpoint was CNR, defined as Thrombolysis in Myocardial Infarction blood flow grade of <3 after the PCI. RESULTS: CNR occurred in 130 patients: 127 patients in the group with aspirin loading and 3 patients in the group without aspirin loading before PCI (4.5% vs. 1.0%; odds ratio [OR] = 4.50, 95% confidence interval, [1.42-14.21], p = 0.005). After adjustment, the association between aspirin loading and CNR was significant (adjusted OR = 4.49 [1.56-12.92]; p < 0.001). There was no aspirin loading-by-P2Y12 inhibitor (ticagrelor or prasugrel) interaction (pint = 0.465) or aspirin loading-by-chronic aspirin therapy on admission (pint = 0.977) interaction with respect to the occurrence of CNR after PCI. Chronic low-dose aspirin therapy on admission was not independently associated with higher risk of CNR after PCI (adjusted OR = 1.06 [0.65-1.72]; p = 0.824). CONCLUSION: In patients with AMI undergoing PCI, aspirin loading before the PCI procedure at the guideline-recommended doses was associated with higher odds of developing CNR. However, due to the limited number of events, the findings should be considered as hypothesis generating.


Subject(s)
Aspirin , Myocardial Infarction , No-Reflow Phenomenon , Percutaneous Coronary Intervention , Platelet Aggregation Inhibitors , Humans , Aspirin/therapeutic use , Male , Female , Middle Aged , Aged , Platelet Aggregation Inhibitors/therapeutic use , ST Elevation Myocardial Infarction/therapy , Administration, Oral , Purinergic P2Y Receptor Antagonists/therapeutic use
13.
Herz ; 49(2): 156-164, 2024 Mar.
Article in German | MEDLINE | ID: mdl-38240775

ABSTRACT

Aortic valve stenosis is one of the most frequent valvular heart diseases requiring treatment in industrialized countries. The symptom onset is associated with a significantly increased mortality, so that there is a clear indication for treatment in patients with severe, symptomatic aortic valve stenosis; however, data on the optimal treatment of patients with asymptomatic aortic valve stenosis are scarce. Smaller studies in the field of cardiac surgery suggest that early surgical valve replacement is superior to a conservative approach. For this reason, the results of additional adequately powered randomized trials are awaited with great interest. In this year numerous long-term results from randomized comparisons of the two available treatment options (surgical versus transcatheter aortic valve replacement) were published, which will further guide the heart team to find the best treatment approach for each individual.


Subject(s)
Aortic Valve Stenosis , Heart Valve Diseases , Heart Valve Prosthesis Implantation , Heart Valve Prosthesis , Transcatheter Aortic Valve Replacement , Humans , Aortic Valve Stenosis/diagnosis , Aortic Valve Stenosis/surgery , Heart Valve Diseases/surgery , Transcatheter Aortic Valve Replacement/adverse effects , Heart Valve Prosthesis Implantation/methods , Aortic Valve/diagnostic imaging , Aortic Valve/surgery , Treatment Outcome , Risk Factors
14.
Eur Heart J Cardiovasc Imaging ; 25(2): 175-184, 2024 Jan 29.
Article in English | MEDLINE | ID: mdl-37395586

ABSTRACT

AIMS: Coronary microevaginations (CMEs) represent an outward bulge of coronary plaques and have been introduced as a sign of adverse vascular remodelling following coronary device implantation. However, their role in atherosclerosis and plaque destabilization in the absence of coronary intervention is unknown. This study aimed to investigate CME as a novel feature of plaque vulnerability and to characterize its associated inflammatory cell-vessel-wall interactions. METHODS AND RESULTS: A total of 557 patients from the translational OPTICO-ACS study programme underwent optical coherence tomography imaging of the culprit vessel and simultaneous immunophenotyping of the culprit lesion (CL). Two hundred and fifty-eight CLs had a ruptured fibrous cap (RFC) and one hundred had intact fibrous cap (IFC) acute coronary syndrome (ACS) as an underlying pathophysiology. CMEs were significantly more frequent in CL when compared with non-CL (25 vs. 4%, P < 0.001) and were more frequently observed in lesions with IFC-ACS when compared with RFC-ACS (55.0 vs. 12.7%, P < 0.001). CMEs were particularly prevalent in IFC-ACS-causing CLs independent of a coronary bifurcation (IFC-ICB) when compared with IFC-ACS with an association to a coronary bifurcation (IFC-ACB, 65.4 vs. 43.7%, P = 0.030). CME emerged as the strongest independent predictor of IFC-ICB (relative risk 3.36, 95% confidence interval 1.67-6.76, P = 0.001) by multivariable regression analysis. IFC-ICB demonstrated an enrichment of monocytes in both culprit blood analysis (culprit ratio: 1.1 ± 0.2 vs. 0.9 ± 0.2, P = 0.048) and aspirated culprit thrombi (326 ± 162 vs. 96 ± 87 cells/mm2, P = 0.017), while IFC-ACB confirmed the accumulation of CD4+ T cells, as recently described. CONCLUSION: This study provides novel evidence for a pathophysiological involvement of CME in the development of IFC-ACS and provides first evidence for a distinct pathophysiological pathway for IFC-ICB, driven by CME-derived flow disturbances and inflammatory activation involving the innate immune system. TRIAL REGISTRATION: Registration of the study at clinicalTrials.gov (NCT03129503).


Subject(s)
Acute Coronary Syndrome , Coronary Artery Disease , Plaque, Atherosclerotic , Humans , Acute Coronary Syndrome/diagnosis , Prospective Studies , Plaque, Atherosclerotic/complications , Heart , Fibrosis , Rupture/complications , Rupture/metabolism , Rupture/pathology , Coronary Vessels/diagnostic imaging , Coronary Vessels/pathology , Tomography, Optical Coherence/methods , Coronary Angiography/methods , Coronary Artery Disease/diagnostic imaging , Coronary Artery Disease/complications
15.
JACC Cardiovasc Interv ; 17(1): 1-13, 2024 Jan 08.
Article in English | MEDLINE | ID: mdl-37902151

ABSTRACT

BACKGROUND: Treatment of patients with recurrence of in-stent restenosis (ISR) remains particularly challenging, with data and guideline recommendations for repeat percutaneous coronary intervention being scant. OBJECTIVES: The aim of this study was to investigate the long-term incidence of recurrent revascularization events after percutaneous treatment of drug-eluting stent (DES) ISR. METHODS: In this post hoc analysis, 402 patients (500 lesions) assigned to plain balloon (PB), drug-coated balloon (DCB), or DES treatment in the randomized ISAR-DESIRE 3 (Efficacy Study of Paclitaxel-Eluting Balloon, -Stent vs. Plain Angioplasty for Drug-Eluting Stent Restenosis) trial were followed up over a median of 10.3 years. The primary endpoint was total repeat target lesion revascularization (R-TLR) including all, first and recurrent, events. RESULTS: At the end of follow-up, first R-TLR was required in 204 lesions, 82 in the PB group, 70 in the DCB group, and 52 in the DES group. The total number of R-TLRs was 373: 162 in the PB group, 124 in the DCB group, and 87 in the DES group. During the first year of follow-up, the risk for total R-TLR was reduced by DCB (HR: 0.36; 95% CI: 0.24-0.54) and DES (HR: 0.23; 95% CI: 0.14-0.38) treatment compared with PB treatment. After 1 year, the risk for total R-TLR was nonsignificantly reduced by DCB treatment (HR: 0.77; 95% CI: 0.51-1.16) and significantly reduced by DES treatment (HR: 0.61; 95% CI: 0.39-0.95) compared with PB treatment. Risk in the DCB and DES groups was similar during (HR: 1.54; 95% CI: 0.89-2.69) and after (HR: 1.26; 95% CI: 0.82-1.92) 1 year. CONCLUSIONS: The total number of R-TLRs over 10 years after treatment of patients with DES ISR was high. DCBs and particularly DES were able to reduce the need for both first and recurrent revascularization compared with PB treatment.


Subject(s)
Coronary Restenosis , Drug-Eluting Stents , Humans , Angioplasty, Balloon, Coronary , Coated Materials, Biocompatible , Coronary Angiography , Coronary Restenosis/diagnostic imaging , Coronary Restenosis/etiology , Coronary Restenosis/therapy , Drug-Eluting Stents/adverse effects , Paclitaxel , Percutaneous Coronary Intervention , Treatment Outcome , Randomized Controlled Trials as Topic
16.
Eur Heart J Cardiovasc Imaging ; 25(4): 491-497, 2024 Mar 27.
Article in English | MEDLINE | ID: mdl-37936296

ABSTRACT

AIMS: The aim of the study is to assess the impact of the baseline plaque composition on the DREAMS 3G luminal late loss and to compare the serial plaque changes between baseline and 6 and 12 months (M) follow-up. METHODS AND RESULTS: A total of 116 patients were enrolled in the BIOMAG-I trial. Patients were imaged with optical coherence tomography (OCT) pre- and post-DREAMS 3G implantation and at 6 and 12 M. OCTPlus software uses artificial intelligence to assess composition (i.e. lipid, calcium, and fibrous tissue) of the plaque. The differences between the OCT-derived minimum lumen area (MLA) post-percutaneous coronary intervention and 12 M were grouped into three terciles. Patients with larger MLA differences at 12 M (P = 0.0003) had significantly larger content of fibrous tissue at baseline. There was a reduction of 24.8% and 20.9% in lipid area, both P < 0.001, between the pre-DREAMS 3G OCT and the 6 and 12 M follow-up. Conversely, the fibrous tissue increased by 48.4% and 36.0% at 6 and 12 M follow-up, both P < 0.001. CONCLUSION: The larger the fibrous tissue in the lesion at baseline, the larger the luminal loss seen at 6 and 12 M. Following the implantation of DREAMS 3G, favourable healing of the vessel coronary wall occurs as shown by a decrease in the lipid area and an increase in fibrous tissue.


Subject(s)
Coronary Artery Disease , Drug-Eluting Stents , Percutaneous Coronary Intervention , Plaque, Atherosclerotic , Humans , Absorbable Implants , Artificial Intelligence , Coronary Angiography , Coronary Vessels , Lipids , Tomography, Optical Coherence/methods , Treatment Outcome
17.
Clin Res Cardiol ; 113(2): 276-287, 2024 Feb.
Article in English | MEDLINE | ID: mdl-37870627

ABSTRACT

OBJECTIVES: Systemic inflammatory response syndrome (SIRS) is a common finding after cardiovascular interventions. Data on the incidence of SIRS and its impact on outcome in patients undergoing transcatheter edge-to-edge mitral valve repair (MV-TEER) for mitral regurgitation (MR) is lacking. METHODS: From January 2013 to December 2020, 373 patients with moderate or severe MR undergoing MV-TEER were included. SIRS was defined as at least two of the following criteria within 48 h after the procedure: leucocyte count > 12.0 or < 4.0 × 109/l, respiratory rate > 20 breaths per minute or PaCO2 ≤ 4.3 kPa/32 mmHg, heart rate > 90 bpm and temperature > 38.0 °C or < 36.0 °C. The primary endpoint was 3-years all-cause mortality. RESULTS: SIRS was observed in 49.6% (185/373) of patients. Patients who developed SIRS presented more frequently with NYHA III/IV at baseline [SIRS: 82.4% (149/185) vs. no SIRS: 79.0% (147/188); p = 0.029]. Patients who developed SIRS spent more days on ICU (p < 0.001) and overall length of stay was longer (p < 0.001). Relevant residual MR, defined as MR ≥ III in-hospital, was present more often in patients who developed SIRS [SIRS: 11.3% (20/177) vs. no SIRS: 3.93% (7/178), p = 0.036]. At 3 years, all-cause mortality in the entire population was 33.5% (125/373) with an increased all-cause mortality in patients with SIRS compared to patients without SIRS (HR 1.49, [CI 95% 1.04, 2.13]; p = 0.0264). In the multivariate analysis development of SIRS (HR 1.479 [CI 95% 1.016, 2.154]; p = 0.041) was identified as predictor for 3-years all-cause mortality. CONCLUSIONS: SIRS is a common finding after MV-TEER occurring in approximately half of patients. SIRS after MV-TEER was associated with a longer in-hospital stay. In addition, we observed an increased 3-years all-cause mortality in patients with SIRS.


Subject(s)
Cardiac Surgical Procedures , Heart Valve Prosthesis Implantation , Mitral Valve Insufficiency , Humans , Incidence , Mitral Valve/diagnostic imaging , Mitral Valve/surgery , Systemic Inflammatory Response Syndrome/diagnosis , Systemic Inflammatory Response Syndrome/epidemiology , Systemic Inflammatory Response Syndrome/etiology , Heart Rate , Mitral Valve Insufficiency/diagnosis , Mitral Valve Insufficiency/epidemiology , Mitral Valve Insufficiency/surgery , Treatment Outcome , Heart Valve Prosthesis Implantation/adverse effects
18.
Eur Heart J Cardiovasc Imaging ; 25(4): 558-572, 2024 Mar 27.
Article in English | MEDLINE | ID: mdl-37996066

ABSTRACT

AIMS: Right ventricular to pulmonary artery (RV-PA) coupling has been established as a prognostic marker in patients with severe tricuspid regurgitation (TR) undergoing transcatheter tricuspid valve interventions (TTVI). RV-PA coupling assesses right ventricular systolic function related to pulmonary artery pressure levels, which are ideally measured by right heart catheterization. This study aimed to improve the RV-PA coupling concept by relating tricuspid annular plane systolic excursion (TAPSE) to mean pulmonary artery pressure (mPAP) levels. Moreover, instead of right heart catheterization, this study sought to employ an extreme gradient boosting (XGB) algorithm to predict mPAP levels based on standard echocardiographic parameters. METHODS AND RESULTS: This multicentre study included 737 patients undergoing TTVI for severe TR; among them, 55 patients from one institution served for external validation. Complete echocardiography and right heart catheterization data were available from all patients. The XGB algorithm trained on 10 echocardiographic parameters could reliably predict mPAP levels as evaluated on right heart catheterization data from external validation (Pearson correlation coefficient R: 0.68; P value: 1.3 × 10-8). Moreover, predicted mPAP (mPAPpredicted) levels were superior to echocardiographic systolic pulmonary artery pressure (sPAPechocardiography) levels in predicting 2-year mortality after TTVI [area under the curve (AUC): 0.607 vs. 0.520; P value: 1.9 × 10-6]. Furthermore, TAPSE/mPAPpredicted was superior to TAPSE/sPAPechocardiography in predicting 2-year mortality after TTVI (AUC: 0.633 vs. 0.586; P value: 0.008). Finally, patients with preserved RV-PA coupling (defined as TAPSE/mPAPpredicted > 0.617 mm/mmHg) showed significantly higher 2-year survival rates after TTVI than patients with reduced RV-PA coupling (81.5% vs. 58.8%, P < 0.001). Moreover, independent association between TAPSE/mPAPpredicted levels and 2-year mortality after TTVI was confirmed by multivariate regression analysis (P value: 6.3 × 10-4). CONCLUSION: Artificial intelligence-enabled RV-PA coupling assessment can refine risk stratification prior to TTVI without necessitating invasive right heart catheterization. A comparison with conservatively treated patients is mandatory to quantify the benefit of TTVI in accordance with RV-PA coupling.


Subject(s)
Tricuspid Valve Insufficiency , Ventricular Dysfunction, Right , Humans , Tricuspid Valve , Pulmonary Artery/diagnostic imaging , Artificial Intelligence , Echocardiography , Heart Ventricles/diagnostic imaging , Ventricular Function, Right
19.
Clin Res Cardiol ; 113(1): 38-47, 2024 Jan.
Article in English | MEDLINE | ID: mdl-37115228

ABSTRACT

BACKGROUND: New-generation self-expanding transcatheter aortic heart valves (THV) were designed to overcome technical constraints of their preceding generations. We sought to compare the efficacy and safety of the self-expanding ACURATE neo2 (Neo2) versus Evolut PRO (PRO) devices. METHODS: Seven hundred nine patients undergoing transfemoral transcatheter aortic valve implantation (TAVI) with either Neo2 (n = 496) or PRO (n = 213) were included. Propensity score matching (PSM) was performed to account for differences in baseline characteristics. In-hospital and 30-day clinical outcomes were evaluated according to Valve Academic Research Consortium-3 criteria. RESULTS: Baseline characteristics were comparable between both groups after PSM (Neo2: n = 155, Evolut Pro: n = 155). Technical success rates were high in both groups (Neo2: 94.8% vs PRO: 97.4%; p = 0.239). Need for permanent pacemaker implantation was less frequent with Neo2 compared with PRO (7.5% vs 20.6%; p = 0.002), whereas major vascular complications were more frequent with Neo2 (Neo2: 11.6% vs PRO: 4.5%; p = 0.022). Intended valve performance at discharge was high in both groups without relevant differences among groups (Neo2: 97.4% vs. 95.3%; p = 0.328). CONCLUSIONS: Short-term outcomes after TAVI using latest-generation self-expanding THV were excellent, with overall low rates of adverse events. However, Neo2 was associated with lower pacemaker rates and reduced the prevalence of moderate-severe paravalvular leakage. Transprosthetic gradients after TAVI were higher with Neo2 compared with PRO.


Subject(s)
Aortic Valve Stenosis , Heart Valve Prosthesis , Transcatheter Aortic Valve Replacement , Humans , Transcatheter Aortic Valve Replacement/adverse effects , Aortic Valve/surgery , Aortic Valve Stenosis/surgery , Prosthesis Design , Treatment Outcome
SELECTION OF CITATIONS
SEARCH DETAIL
...