Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 1 de 1
Filter
Add more filters










Database
Language
Publication year range
1.
Catheter Cardiovasc Interv ; 92(4): 797-807, 2018 10 01.
Article in English | MEDLINE | ID: mdl-30091509

ABSTRACT

OBJECTIVES: We aimed to evaluate diastolic leaflet tethering as a factor that may cause mitral stenosis (MS) after simulated MitraClip implantation, using an in vitro left heart simulator. BACKGROUND: Leaflet tethering commonly seen in functional mitral regurgitation may be a significant factor affecting the severity of MS after MitraClip implantation. METHODS: A left heart simulator with excised ovine mitral valves (N = 6), and custom edge-to-edge clip devices (GTclip) was used to mimic implantation of MitraClip in a variety of positions. Anterior mitral leaflet (AML) tethering severity was varied for each case (leaflet excursion of 75°, 60°, and 45°, consistent with mild, moderate and severe tethering), and the baseline mitral annular area (MAA) was varied across samples (3.6-4.8 cm2 ). The resulting mitral valve area (MVA), and peak/mean mitral valve gradient (MVG) were measured in each case. RESULTS: AML tethering severity was a highly significant factor increasing MVG and decreasing MVA (P < 0.001). When GTclip placement was simulated with severe AML tethering, mean MVG >5 mmHg resulted more frequently than with GTclip placement alone (46% vs. 4%, respectively). However, severe AML tethering alone significantly reduced baseline MVA to 3.6 ± 0.2 cm2 , and increased baseline MVG to 3.0 ± 0.4 mmHg. At MAA above 4.7 cm2 , severe AML tethering did not cause moderate MS, even with placement of two GTclips (95% confidence). CONCLUSIONS: Our results show that diastolic AML tethering may predispose to MS after clip placement, however, MS was not observed when baseline MVA was above 4.0 cm2 . Severity of AML tethering may be an important criterion in selecting patients for edge-to-edge repair.


Subject(s)
Heart Valve Prosthesis Implantation/instrumentation , Heart Valve Prosthesis , Hemodynamics , Mitral Valve Annuloplasty/instrumentation , Mitral Valve Stenosis/etiology , Mitral Valve/surgery , Animals , Computer Simulation , Heart Valve Prosthesis Implantation/adverse effects , Humans , Mitral Valve/diagnostic imaging , Mitral Valve/physiopathology , Mitral Valve Annuloplasty/adverse effects , Mitral Valve Stenosis/diagnostic imaging , Mitral Valve Stenosis/physiopathology , Models, Cardiovascular , Prosthesis Design , Risk Factors , Severity of Illness Index , Sheep, Domestic , Treatment Outcome
SELECTION OF CITATIONS
SEARCH DETAIL
...