Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 35
Filter
1.
Sci Rep ; 12(1): 9763, 2022 06 13.
Article in English | MEDLINE | ID: mdl-35697705

ABSTRACT

Investigators have reported reduced visibility of the cone photoreceptors overlying drusen using adaptive optics (AO) imaging techniques. Two hypotheses have been proposed to explain this phenomenon. First, the disease-related deformation of the photoreceptor outer segment (OS) may reduce its ability to act as a wave guide, thus decreasing the cell's familiar reflectance pattern. Second, drusen could disorient the photoreceptors away from the eye's pupil, reducing the amount of light reflected back out the pupil. In this work, we use directional OCT (dOCT) images of drusen in AMD patients to measure the respective contributions of these deforming and disorienting factors.


Subject(s)
Retinal Cone Photoreceptor Cells , Tomography, Optical Coherence , Humans , Optics and Photonics , Tomography, Optical Coherence/methods
2.
Opt Express ; 29(20): 32179-32195, 2021 Sep 27.
Article in English | MEDLINE | ID: mdl-34615295

ABSTRACT

Full-field swept-source optical coherence tomography (FF-SS-OCT) is an emerging technology with potential applications in ophthalmic imaging, microscopy, metrology, and other domains. Here we demonstrate a novel method of multiplexing FF-SS-OCT signals using carrier modulation (CM). The principle of CM could be used to inspect various properties of the scattered light, e.g. its spectrum, polarization, Doppler shift, or distribution in the pupil. The last of these will be explored in this work, where CM was used to acquire images passing through two different optical pupils. The two pupils contained semicircular optical windows with perpendicular orientations, with each window permitting measurement of scattering anisotropy in one dimension by inducing an optical delay between the images formed by the two halves of the pupil. Together, the two forms of multiplexing permit measurement of differential scattering anisotropy in the x and y dimensions simultaneously. To demonstrate the feasibility of this technique our carrier multiplexed directional FF-OCT (CM-D-FF-OCT) system was used to acquire images of a microlens array, human hair, onion skin and in vivo human retina. The results of these studies are presented and briefly discussed in the context of future development and application of this technique.


Subject(s)
Light , Scattering, Radiation , Tomography, Optical Coherence/methods , Anisotropy , Artifacts , Feasibility Studies , Fourier Analysis , Hair/diagnostic imaging , Humans , Interferometry , Onions , Retina/diagnostic imaging , Retinal Cone Photoreceptor Cells/physiology , Semiconductors , Tomography, Optical Coherence/instrumentation , Tomography, Optical Coherence/trends
3.
Ann Transl Med ; 9(15): 1270, 2021 Aug.
Article in English | MEDLINE | ID: mdl-34532407

ABSTRACT

The past few years have witnessed rapid development of the optoretinogram-a noninvasive, optical measurement of neural function in the retina, and especially the photoreceptors (Ph). While its recent development has been rapid, it represents the culmination of hundreds of experiments spanning decades. Early work showed measurable and reproducible changes in the optical properties of retinal explants and suspensions of Ph, and uncovered some of the biophysical and biochemical mechanisms underlying them. That work thus provided critical motivation for more recent work based on clinical imaging platforms, whose eventual goal is the improvement of ophthalmic care and streamlining the discovery of novel therapeutics. The first part of this review consists of a selective summary of the early work, and identifies four kinds of stimulus-evoked optical signals that have emerged from it: changes in light scattered from the membranous discs of the Ph's outer segment (OS), changes in light scattered by the front and back boundaries of the OS, rearrangement of scattering material in and near the OS, and changes in the OS length. In the past decade, all four of these signals have continued to be investigated using imaging systems already used in the clinic or intended for clinical and translational use. The second part of this review discusses these imaging modalities, their potential to detect and quantify the signals of interest, and other factors influencing their translational promise. Particular attention is paid to phase-sensitive optical coherence tomography (OCT) with adaptive optics (AO), a method in which both the amplitude and the phase of light reflected from individual Ph is monitored as visible stimuli are delivered to them. The record of the light's phase is decoded to reveal a reproducible pattern of deformation in the OS, while the amplitude reveals changes in scattering and structural rearrangements. The method has been demonstrated in a few labs and has been used to measure responses from both rods and cones. With the ability to detect responses to stimuli isomerizing less than 0.01% of photopigment, this technique may prove to be a quick, noninvasive, and objective way to measure subtle disease-related dysfunction at the cellular level, and thus to provide an entirely new and complementary biomarker for retinal disease and recovery.

4.
Biomed Opt Express ; 11(10): 5995-6011, 2020 Oct 01.
Article in English | MEDLINE | ID: mdl-33150001

ABSTRACT

A retinal imaging system was designed for full-field (FF) swept-source (SS) optical coherence tomography (OCT) with cellular resolution. The system incorporates a real-time adaptive optics (AO) subsystem and a very high-speed CMOS sensor, and is capable of acquiring volumetric images of the retina at rates up to 1 kHz. While digital aberration correction (DAC) is an attractive potential alternative to AO, it has not yet been shown to provide resolution allowing visualization of cones in the fovea, where early detection of functional deficits is most critical. Here we demonstrate that FF-SS-OCT with hardware AO permits resolution of foveal cones, imaged at eccentricities of 1° and 2°, with volume rates adequate to measure light-evoked changes in photoreceptors. With the reference arm blocked, the system can operate as a kilohertz AO flood illumination fundus camera with adjustable temporal coherence and is expected to allow measurement of light-evoked changes caused by common path interference in photoreceptor outer segments (OS). In this paper, we describe the system's optical design, characterize its performance, and demonstrate its ability to produce images of the human photoreceptor mosaic.

5.
Opt Lett ; 45(21): 5945-5948, 2020 Nov 01.
Article in English | MEDLINE | ID: mdl-33137037

ABSTRACT

Here we provide a counter-example to the conventional wisdom in biomedical optics that longer wavelengths aid deeper imaging in tissue. Specifically, we investigate visible light optical coherence tomography of Bruch's membrane (BM) in the non-pathologic eyes of humans and two mouse strains. Surprisingly, we find that shorter visible wavelengths improve the visualization of BM in pigmented eyes, where it is located behind a highly scattering layer of melanosomes in the retinal pigment epithelium (RPE). Monte Carlo simulations of radiative transport suggest that, while absorption and scattering are higher at shorter wavelengths, detected multiply scattered light from the RPE is preferentially attenuated relative to detected backscattered light from the BM.


Subject(s)
Light , Retinal Pigment Epithelium/diagnostic imaging , Scattering, Radiation , Tomography, Optical Coherence/methods , Animals , Bruch Membrane/diagnostic imaging , Humans , Melanosomes/metabolism , Mice , Monte Carlo Method , Retinal Pigment Epithelium/cytology , Signal-To-Noise Ratio
6.
Opt Lett ; 45(17): 4658-4661, 2020 Sep 01.
Article in English | MEDLINE | ID: mdl-32870829

ABSTRACT

Noninvasive, objective measurement of rod function is as significant as that of cone function, and for retinal diseases such as retinitis pigmentosa and age-related macular degeneration, rod function may be a more sensitive biomarker of disease progression and efficacy of treatment than cone function. Functional imaging of single human rod photoreceptors, however, has proven difficult because their small size and rapid functional response pose challenges for the resolution and speed of the imaging system. Here, we describe light-evoked, functional responses of human rods and cones, measured noninvasively using a synchronized adaptive optics optical coherence tomography (OCT) and scanning light ophthalmoscopy (SLO) system. The higher lateral resolution of the SLO images made it possible to confirm the identity of rods in the corresponding OCT volumes.


Subject(s)
Light , Ophthalmoscopy/methods , Retinal Cone Photoreceptor Cells/cytology , Retinal Cone Photoreceptor Cells/radiation effects , Retinal Rod Photoreceptor Cells/cytology , Retinal Rod Photoreceptor Cells/radiation effects , Humans
7.
Biomed Opt Express ; 10(10): 5337-5350, 2019 Oct 01.
Article in English | MEDLINE | ID: mdl-31646049

ABSTRACT

In vivo visualization and quantification of choriocapillaris vascular anatomy is a fundamental step in understanding the relation between choriocapillaris degradation and atrophic retinopathies, including geographic atrophy. We describe a process utilizing ultrahigh-speed swept-source optical coherence tomography and a custom-designed "local min-max normalized masking" algorithm to extract in vivo anatomical metrics of the choriocapillaris. We used a swept-source optical coherence tomography system with a 1.6 MHz A-scan rate to image healthy retinas. With the postprocessing algorithm, we reduced noise, optimized visibility of vasculature, and skeletonized the vasculature within the images. These skeletonizations were in 89 % agreement with those made by skilled technicians and were, on average, completed in 18.6 s as compared to the 5.6 h technicians required. Anatomy within the processed images and skeletonizations was analyzed to identify average values ( mean ± SD ) of flow void radius ( 9.8 ± 0.7 µm ), flow void area ( 749 ± 110 µm 2 ), vessel radius ( 5.0 ± 0.3 µm ), branch-point to branch-point vessel length ( 26.8 ± 1.1 µm ), and branches per branch-point ( 3.1 ± 0.1 ) . To exemplify the uses of this tool a retina with geographic atrophy was imaged and processed to reveal statistically significant ( p < 0.05 ) increases in flow void radii and decreases in vessel radii under atrophic lesions as compared to atrophy-free regions on the same retina. Our results demonstrate a new avenue for quantifying choriocapillaris anatomy and studying vasculature changes in atrophic retinopathies.

8.
Opt Lett ; 44(17): 4219-4222, 2019 Sep 01.
Article in English | MEDLINE | ID: mdl-31465366

ABSTRACT

We describe the details of a multimodal retinal imaging system which combines adaptive optics (AO) with an integrated scanning light ophthalmoscopy (SLO) and optical coherence tomography (OCT) imaging system. The OCT subsystem consisted of a swept-source, Fourier-domain mode-locked (FDML) laser, with a very high A-scan rate (1.6 MHz), whose beam was raster scanned on the retina by two scanners-one resonant scanner and one galvanometer. The high sweep rate of the FDML permitted the SLO and OCT to utilize the same scanners for in vivo retinal imaging and, unlike existing multimodal systems, concurrently acquired SLO frames and OCT volumes with approximate en face correspondence at a rate of 6 Hz. The AO provided diffraction-limited cellular resolution for both imaging channels.


Subject(s)
Optical Phenomena , Retina/diagnostic imaging , Tomography, Optical Coherence/methods , Humans , Signal-To-Noise Ratio , Tomography, Optical Coherence/instrumentation
9.
Biomed Opt Express ; 10(1): 50-65, 2019 Jan 01.
Article in English | MEDLINE | ID: mdl-30775082

ABSTRACT

Angiographic imaging of the human eye with optical coherence tomography (OCT) is becoming an increasingly important tool in the scientific investigation and clinical management of several blinding diseases, including age-related macular degeneration and diabetic retinopathy. We have observed that OCT angiography (OCTA) of the human choriocapillaris and choroid with a 1.64 MHz A-scan rate swept-source laser yields higher contrast images as compared to a slower rate system operating at 100 kHz. This result is unexpected because signal sensitivity is reduced when acquisition rates are increased, and the incident illumination power is kept constant. The contrast of angiography images generated by acquiring multiple sequential frames and calculating the variation caused by blood flow, however, appears to be improved significantly when lower-contrast images are taken more rapidly. To demonstrate that the acquisition rate plays a role in the quality improvement, we have imaged five healthy subjects with a narrow field of view (1.2 mm) OCTA imaging system using two separate swept-source lasers of different A-line rates and compared the results quantitatively using the radially-averaged power spectrum. The average improvement in the contrast is 23.0% (+/-7.6%). Although the underlying cause of this enhancement is not explicitly determined here, we speculate that the higher-speed system suppresses the noise contribution from eye motion in subjects and operates with an inter-scan time that better discriminates the flow velocities present in the choroid and choriocapillaris. Our result informs OCT system developers on the merits of ultrahigh-speed acquisition in functional imaging applications.

10.
Optica ; 6(3): 300-303, 2019 Mar 20.
Article in English | MEDLINE | ID: mdl-33511257

ABSTRACT

Objective optical assessment of photoreceptor function may permit earlier diagnosis of retinal disease than current methods such as perimetry, electrophysiology, and clinical imaging. In this work, we describe an adaptive optics (AO) optical coherence tomography (OCT) system designed to measure functional responses of single cones to visible stimuli. The OCT subsystem consisted of a raster-scanning Fourier-domain mode-locked laser that acquires A scans at 1.64 MHz with a center wavelength of 1063 nm and an AO system operating in closed-loop. Analysis of serial volumetric images revealed phase changes of cone photoreceptors consistent with outer segment elongation and proportional to stimulus intensity, as well as other morphological changes in the outer segment and retinal pigment epithelium.

11.
PLoS One ; 13(10): e0206052, 2018.
Article in English | MEDLINE | ID: mdl-30359401

ABSTRACT

In retinal raster imaging modalities, fixational eye movements manifest as image warp, where the relative positions of the beam and retina change during the acquisition of single frames. To remove warp artifacts, strip-based registration methods-in which fast-axis strips from target images are registered to a reference frame-have been applied in adaptive optics (AO) scanning light ophthalmoscopy (SLO) and optical coherence tomography (OCT). This approach has enabled object tracking and frame averaging, and methods have been described to automatically select reference frames with minimal motion. However, inconspicuous motion artifacts may persist in reference frames and propagate themselves throughout the processes of registration, tracking, and averaging. Here we test a previously proposed method for removing movement artifacts in reference frames, using biases in stripwise cross-correlation statistics. We applied the method to synthetic retinal images with simulated eye motion artifacts as well as real AO-SLO images of the cone mosaic and volumetric AO-OCT images, both affected by eye motion. In the case of synthetic images, the method was validated by direct comparison with motion-free versions of the images. In the case of real AO images, performance was validated by comparing the correlation of uncorrected images with that of corrected images, by quantifying the effect of motion artifacts on the image power spectra, and by qualitative examination of AO-OCT B-scans and en face projections. In all cases, the proposed method reduced motion artifacts and produced more faithful images of the retina.


Subject(s)
Image Processing, Computer-Assisted , Motion , Optics and Photonics , Algorithms , Artifacts , Computer Simulation , Eye/diagnostic imaging , Humans , Ophthalmoscopy
12.
Invest Ophthalmol Vis Sci ; 58(11): 4559-4568, 2017 09 01.
Article in English | MEDLINE | ID: mdl-28877320

ABSTRACT

Purpose: Optical coherence tomography's (OCT) third outer retinal band has been attributed to the zone of interdigitation between RPE cells and cone outer segments. The purpose of this paper is to investigate the structure of this band with adaptive optics (AO)-OCT. Methods: Using AO-OCT, images were obtained from two subjects. Axial structure was characterized by measuring band 3 thickness and separation between bands 2 and 3 in segmented cones. Lateral structure was characterized by correlation of band 3 with band 2 and comparison of their power spectra. Band thickness and separation were also measured in a clinical OCT image of one subject. Results: Band 3 thickness ranged from 4.3 to 6.4 µm. Band 2 correlations ranged between 0.35 and 0.41 and power spectra of both bands confirmed peak frequencies that agree with histologic density measurements. In clinical images, band 3 thickness was between 14 and 19 µm. Measurements of AO-OCT of interband distance were lower than our corresponding clinical OCT measurements. Conclusions: Band 3 originates from a structure with axial extent similar to a single surface. Correlation with band 2 suggests an origin within the cone photoreceptor. These two observations indicate that band 3 corresponds predominantly to cone outer segment tips (COST). Conventional OCT may overestimate both the thickness of band 3 and outer segment length.


Subject(s)
Retina/diagnostic imaging , Retinal Cone Photoreceptor Cells/cytology , Retinal Photoreceptor Cell Outer Segment , Retinal Pigment Epithelium/cytology , Tomography, Optical Coherence/methods , Adult , Female , Fluorescein Angiography , Humans , Visual Acuity , Young Adult
13.
Sci Rep ; 7: 46346, 2017 04 12.
Article in English | MEDLINE | ID: mdl-28402329

ABSTRACT

In old world primates including humans, cone photoreceptors are classified according to their maximal sensitivity at either short (S, blue), middle (M, green) or long (L, red) wavelengths. Colour discrimination studies show that the S-cone pathway is selectively affected by age and disease, and psychophysical models implicate their loss. Photoreceptors have high metabolic demand and are susceptible to age or disease-related losses in oxygen and nutrient supply. Hence 30% of rods are lost over life. While comparable losses are not seen in cones, S-cones comprise less than 10% of the cone population, so significant loss would be undetected in total counts. Here we examine young and aged primate retinae stained to distinguish S from M/L-cones. We show there is no age-related cone loss in either cone type and that S-cones are as regularly distributed in old as young primates. We propose that S-cone metabolism is less flexible than in their M/L counterparts, making them more susceptible to deficits in normal cellular function. Hypoxia is a feature of the ageing retina as extracellular debris accumulates between photoreceptors and their blood supply which likely impacts S-cone function. However, that these cells remain in the ageing retina suggests the potential for functional restoration.


Subject(s)
Aging/physiology , Retina/metabolism , Retinal Cone Photoreceptor Cells/metabolism , Age Factors , Animals , Cell Count , Primates , Retina/physiopathology
14.
Vision Res ; 132: 3-33, 2017 03.
Article in English | MEDLINE | ID: mdl-28212982

ABSTRACT

Adaptive optics is a relatively new field, yet it is spreading rapidly and allows new questions to be asked about how the visual system is organized. The editors of this feature issue have posed a series of question to scientists involved in using adaptive optics in vision science. The questions are focused on three main areas. In the first we investigate the use of adaptive optics for psychophysical measurements of visual system function and for improving the optics of the eye. In the second, we look at the applications and impact of adaptive optics on retinal imaging and its promise for basic and applied research. In the third, we explore how adaptive optics is being used to improve our understanding of the neurophysiology of the visual system.


Subject(s)
Ocular Physiological Phenomena , Optics and Photonics , Retina/physiology , Vision Disorders/rehabilitation , Visual Perception/physiology , Animals , Humans , Psychophysics , Vision Disorders/physiopathology , Vision, Ocular/physiology
15.
Biomed Opt Express ; 7(11): 4554-4568, 2016 Nov 01.
Article in English | MEDLINE | ID: mdl-27895995

ABSTRACT

Cone photoreceptors undergo a daily cycle of renewal and shedding of membranous discs in their outer segments (OS), the portion responsible for light capture. These physiological processes are fundamental to maintaining photoreceptor health, and their dysfunction is associated with numerous retinal diseases. While both processes have been extensively studied in animal models and postmortem eyes, little is known about them in the living eye, in particular human. In this study, we report discovery of the optical signature associated with disc shedding using a method based on adaptive optics optical coherence tomography (AO-OCT) in conjunction with post-processing methods to track and monitor individual cone cells in 4D. The optical signature of disc shedding is characterized by an abrupt transient loss in the cone outer segment tip (COST) reflection followed by its return that is axially displaced anteriorly. Using this signature, we measured the temporal and spatial properties of shedding events in three normal subjects. Average duration of the shedding event was 8.8 ± 13.4 minutes, and average length loss of the OS was 2.1 µm (7.0% of OS length). Prevalence of cone shedding was highest in the morning (14.3%) followed by the afternoon (5.7%) and evening (4.0%), with load distributed across the imaged patch. To the best of our knowledge these are the first images of photoreceptor disc shedding in the living retina.

16.
Invest Ophthalmol Vis Sci ; 57(9): OCT51-68, 2016 07 01.
Article in English | MEDLINE | ID: mdl-27409507

ABSTRACT

PURPOSE: Optical coherence tomography (OCT) has enabled "virtual biopsy" of the living human retina, revolutionizing both basic retina research and clinical practice over the past 25 years. For most of those years, in parallel, adaptive optics (AO) has been used to improve the transverse resolution of ophthalmoscopes to foster in vivo study of the retina at the microscopic level. Here, we review work done over the last 15 years to combine the microscopic transverse resolution of AO with the microscopic axial resolution of OCT, building AO-OCT systems with the highest three-dimensional resolution of any existing retinal imaging modality. METHODS: We surveyed the literature to identify the most influential antecedent work, important milestones in the development of AO-OCT technology, its applications that have yielded new knowledge, research areas into which it may productively expand, and nascent applications that have the potential to grow. RESULTS: Initial efforts focused on demonstrating three-dimensional resolution. Since then, many improvements have been made in resolution and speed, as well as other enhancements of acquisition and postprocessing techniques. Progress on these fronts has produced numerous discoveries about the anatomy, function, and optical properties of the retina. CONCLUSIONS: Adaptive optics OCT continues to evolve technically and to contribute to our basic and clinical knowledge of the retina. Due to its capacity to reveal cellular and microscopic detail invisible to clinical OCT systems, it is an ideal companion to those instruments and has the demonstrable potential to produce images that can guide the interpretation of clinical findings.


Subject(s)
Biomedical Research/trends , Ophthalmology/trends , Optics and Photonics , Retina/diagnostic imaging , Tomography, Optical Coherence/instrumentation , Equipment Design , Humans
17.
Biomed Opt Express ; 6(6): 2191-210, 2015 Jun 01.
Article in English | MEDLINE | ID: mdl-26114038

ABSTRACT

Adaptive optics scanning laser ophthalmoscopy (AO-SLO) has recently been used to achieve exquisite subcellular resolution imaging of the mouse retina. Wavefront sensing-based AO typically restricts the field of view to a few degrees of visual angle. As a consequence the relationship between AO-SLO data and larger scale retinal structures and cellular patterns can be difficult to assess. The retinal vasculature affords a large-scale 3D map on which cells and structures can be located during in vivo imaging. Phase-variance OCT (pv-OCT) can efficiently image the vasculature with near-infrared light in a label-free manner, allowing 3D vascular reconstruction with high precision. We combined widefield pv-OCT and SLO imaging with AO-SLO reflection and fluorescence imaging to localize two types of fluorescent cells within the retinal layers: GFP-expressing microglia, the resident macrophages of the retina, and GFP-expressing cone photoreceptor cells. We describe in detail a reflective afocal AO-SLO retinal imaging system designed for high resolution retinal imaging in mice. The optical performance of this instrument is compared to other state-of-the-art AO-based mouse retinal imaging systems. The spatial and temporal resolution of the new AO instrumentation was characterized with angiography of retinal capillaries, including blood-flow velocity analysis. Depth-resolved AO-SLO fluorescent images of microglia and cone photoreceptors are visualized in parallel with 469 nm and 663 nm reflectance images of the microvasculature and other structures. Additional applications of the new instrumentation are discussed.

19.
Invest Ophthalmol Vis Sci ; 56(1): 81-9, 2014 Dec 09.
Article in English | MEDLINE | ID: mdl-25491299

ABSTRACT

PURPOSE: Because human bone marrow (BM) CD34+ stem cells home into damaged tissue and may play an important role in tissue repair, this pilot clinical trial explored the safety and feasibility of intravitreal autologous CD34+ BM cells as potential therapy for ischemic or degenerative retinal conditions. METHODS: This prospective study enrolled six subjects (six eyes) with irreversible vision loss from retinal vascular occlusion, hereditary or nonexudative age-related macular degeneration, or retinitis pigmentosa. CD34+ cells were isolated under Good Manufacturing Practice conditions from the mononuclear cellular fraction of the BM aspirate using a CliniMACs magnetic cell sorter. After intravitreal CD34+ cell injection, serial ophthalmic examinations, microperimetry/perimetry, fluorescein angiography, electroretinography (ERG), optical coherence tomography (OCT), and adaptive optics OCT were performed during the 6-month follow-up. RESULTS: A mean of 3.4 million (range, 1-7 million) CD34+ cells were isolated and injected per eye. The therapy was well tolerated with no intraocular inflammation or hyperproliferation. Best-corrected visual acuity and full-field ERG showed no worsening after 6 months. Clinical examination also showed no worsening during follow-up except among age-related macular degeneration subjects in whom mild progression of geographic atrophy was noted in both the study eye and contralateral eye at 6-month follow-up, concurrent with some possible decline on multifocal ERG and microperimetry. Cellular in vivo imaging using adaptive optics OCT showed changes suggestive of new cellular incorporation into the macula of the hereditary macular degeneration study eye. CONCLUSIONS: Intravitreal autologous BM CD34+ cell therapy appears feasible and well tolerated in eyes with ischemic or degenerative retinal conditions and merits further exploration. (ClinicalTrials.gov number, NCT01736059.).


Subject(s)
Antigens, CD34/immunology , Bone Marrow Cells/immunology , Cell Transplantation/methods , Ischemia/therapy , Retinal Degeneration/therapy , Adult , Aged , Aged, 80 and over , Bone Marrow Cells/cytology , Female , Fluorescein Angiography , Follow-Up Studies , Fundus Oculi , Humans , Intravitreal Injections , Ischemia/diagnosis , Ischemia/immunology , Male , Prospective Studies , Retinal Degeneration/diagnosis , Retinal Degeneration/immunology , Retinal Diseases/diagnosis , Retinal Diseases/immunology , Retinal Diseases/therapy , Treatment Outcome , Visual Acuity , Young Adult
20.
Invest Ophthalmol Vis Sci ; 55(12): 7904-18, 2014 Oct 16.
Article in English | MEDLINE | ID: mdl-25324288

ABSTRACT

PURPOSE: To test the recently proposed hypothesis that the second outer retinal band, observed in clinical OCT images, originates from the inner segment ellipsoid, by measuring: (1) the thickness of this band within single cone photoreceptors, and (2) its respective distance from the putative external limiting membrane (band 1) and cone outer segment tips (band 3). METHODS: Adaptive optics-optical coherence tomography images were acquired from four subjects without known retinal disease. Images were obtained at foveal (2°) and perifoveal (5°) locations. Cone photoreceptors (n = 9593) were identified and segmented in three dimensions using custom software. Features corresponding to bands 1, 2, and 3 were automatically identified. The thickness of band 2 was assessed in each cell by fitting the longitudinal reflectance profile of the band with a Gaussian function. Distances between bands 1 and 2, and between 2 and 3, respectively, were also measured in each cell. Two independent calibration techniques were employed to determine the depth scale (physical length per pixel) of the imaging system. RESULTS: When resolved within single cells, the thickness of band 2 is a factor of three to four times narrower than in corresponding clinical OCT images. The distribution of band 2 thickness across subjects and eccentricities had a modal value of 4.7 µm, with 48% of the cones falling between 4.1 and 5.2 µm. No significant differences were found between cells in the fovea and perifovea. The distance separating bands 1 and 2 was found to be larger than the distance between bands 2 and 3, across subjects and eccentricities, with a significantly larger difference at 5° than 2°. CONCLUSIONS: On the basis of these findings, we suggest that ascription of the outer retinal band 2 to the inner segment ellipsoid is unjustified, because the ellipsoid is both too thick and proximally located to produce the band.


Subject(s)
Diagnostic Techniques, Ophthalmological , Retina/anatomy & histology , Tomography, Optical Coherence , Basement Membrane/anatomy & histology , Humans , Models, Anatomic , Retinal Cone Photoreceptor Cells/cytology , Retinal Photoreceptor Cell Inner Segment , Retinal Photoreceptor Cell Outer Segment , Tomography, Optical Coherence/methods
SELECTION OF CITATIONS
SEARCH DETAIL
...