Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 8 de 8
Filter
Add more filters










Database
Language
Publication year range
1.
Front Psychol ; 6: 111, 2015.
Article in English | MEDLINE | ID: mdl-25713550

ABSTRACT

One of the presumed pathways linking negative emotions to adverse somatic health is an overactive HPA-axis, usually indicated by elevated cortisol levels. Traditionally, research has focused on consciously reported negative emotions. Yet, given that the majority of information processing occurs without conscious awareness, stress physiology might also be influenced by affective processes that people are not aware of. In a 24-h ambulatory study we examined whether cortisol levels were associated with two implicit measures. Implicit affect was assessed using the Implicit Positive and Negative Affect Test, and implicit negative memory bias was assessed with the word fragment completion tasks. In 55 healthy participants, we measured subjective stress levels, worries, implicit, and explicit affect each hour during waking hours. Also, saliva samples were collected at three fixed times during the day, as well as upon waking and 30 min thereafter (cortisol awakening response). Multilevel analyses of the daytime cortisol levels revealed that the presence of an implicit negative memory bias was associated with increased cortisol levels. Additionally, implicit PA and, unexpectedly, implicit NA were negatively associated with cortisol levels. Finally, participants demonstrating higher levels of implicit sadness during the first measurement day, had a stronger cortisol rise upon awakening at the next day. Contrary to previous research, no associations between explicit affect and cortisol were apparent. The current study was the first to examine the concurrent relation between implicit measures and stress physiology in daily life. The results suggest that the traditional focus on consciously reported feelings and emotions is limited, and that implicit measures can add to our understanding of how stress and emotions contribute to daily physiological activity and, in the long term, health problems.

2.
Phys Med Biol ; 58(16): 5495-510, 2013 Aug 21.
Article in English | MEDLINE | ID: mdl-23880523

ABSTRACT

AX-PET is a novel PET detector based on axially oriented crystals and orthogonal wavelength shifter (WLS) strips, both individually read out by silicon photo-multipliers. Its design decouples sensitivity and spatial resolution, by reducing the parallax error due to the layered arrangement of the crystals. Additionally the granularity of AX-PET enhances the capability to track photons within the detector yielding a large fraction of inter-crystal scatter events. These events, if properly processed, can be included in the reconstruction stage further increasing the sensitivity. Its unique features require dedicated Monte-Carlo simulations, enabling the development of the device, interpreting data and allowing the development of reconstruction codes. At the same time the non-conventional design of AX-PET poses several challenges to the simulation and modeling tasks, mostly related to the light transport and distribution within the crystals and WLS strips, as well as the electronics readout. In this work we present a hybrid simulation tool based on an analytical model and a Monte-Carlo based description of the AX-PET demonstrator. It was extensively validated against experimental data, providing excellent agreement.


Subject(s)
Monte Carlo Method , Positron-Emission Tomography/instrumentation
3.
Phys Med Biol ; 49(12): 2547-62, 2004 Jun 21.
Article in English | MEDLINE | ID: mdl-15272673

ABSTRACT

A novel concept for a positron emission tomography (PET) camera module is proposed, which provides full 3D reconstruction with high resolution over the total detector volume, free of parallax errors. The key components are a matrix of long scintillator crystals and hybrid photon detectors (HPDs) with matched segmentation and integrated readout electronics. The HPDs read out the two ends of the scintillator package. Both excellent spatial (x, y, z) and energy resolution are obtained. The concept allows enhancing the detection efficiency by reconstructing a significant fraction of events which underwent Compton scattering in the crystals. The proof of concept will first be demonstrated with yttrium orthoaluminate perovskite (YAP):Ce crystals, but the final design will rely on other scintillators more adequate for PET applications (e.g. LSO:Ce or LaBr3:Ce). A promising application of the proposed camera module, which is currently under development, is a high resolution 3D brain PET camera with an axial field-of-view of approximately 15 cm dedicated to brain research. The design philosophy and performance predictions based on analytical calculations and Monte Carlo simulations are presented. Image correction and reconstruction tools required to operate this transmissionless device in a research environment are also discussed. Better or similar performance parameters were obtained compared to other known designs at lower fabrication cost. The axial geometrical concept also seems to be promising for applications such as positron emission mammography.


Subject(s)
Brain/diagnostic imaging , Equipment Failure Analysis , Image Enhancement/instrumentation , Imaging, Three-Dimensional/instrumentation , Positron-Emission Tomography/instrumentation , Brain/metabolism , Equipment Design , Feasibility Studies , Gamma Cameras , Positron-Emission Tomography/methods , Radiopharmaceuticals/pharmacokinetics , Reproducibility of Results , Research/instrumentation , Sensitivity and Specificity
SELECTION OF CITATIONS
SEARCH DETAIL
...