Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 3 de 3
Filter
Add more filters










Database
Language
Publication year range
1.
Neth Heart J ; 17(6): 245-9, 2009 Jun.
Article in English | MEDLINE | ID: mdl-19789687

ABSTRACT

Monomorphic ventricular tachycardia (VT) and symptomatic monomorphic PVCs originating from the region of the right and left outflow tracts are increasingly treated by radiofrequency (RF) catheter ablation. Technical difficulties in catheter manipulation to access these outflow tract areas, very accurate mapping and reliable catheter stability are key issues for a successful treatment in this vulnerable region. VT ablation from the aortic sinus cusp (ASC) in particular carries a significant risk of perforation, of creating left coronary artery injury and of damage to the aorta and the aortic valve.This case series describes RF ablation of VT originating in the outflow region using the remote magnetic navigation system (MNS). Potential advantages of the MNS are catheter flexibility, steering accuracy and reproducibility to navigate to a desired location with a low probability of perforating the myocardium. This report supports the idea of using advanced MNS technology during RF ablation in regions which are difficult to reach and thin walled, such as parts of the outflow tract and the ASC. (Neth Heart J 2009;17:245-9.).

2.
Neth Heart J ; 12(1): 18-22, 2004 Jan.
Article in English | MEDLINE | ID: mdl-25696255

ABSTRACT

Today, new pacing algorithms and stimulation methods for the prevention and interruption of atrial tachyarrhythmias can be applied on patients who need bradycardia pacing for conventional reasons. In addition, biventricular pacing as additive treatment for patients with severe congestive heart failure due to ventricular systolic dysfunction and prolonged intraventricular conduction has shown to improve symptoms and reduce hospital admissions. These new pacing technologies and the optimising of the pacing programmes are complex, expensive and time-consuming. Based on many clinical studies the indications for these devices are beginning to emerge. To support the cardiologist's decision-making and to prevent waste of effort and resources, the 'ad hoc committee' has provided preliminary recommendations for implantable devices to treat atrial tachyarrhythmias and to extend the treatment of congestive heart failure respectively.

3.
Neth Heart J ; 9(6): 216-221, 2001 Sep.
Article in English | MEDLINE | ID: mdl-25696731

ABSTRACT

BACKGROUND: The implantable cardioverter defibrillator (ICD) has become a widely accepted therapy for patients with severe life-threatening ventricular tachyarrhythmias. The aim of this study was to illustrate the possible advantages of ICDs with respect to survival and clinical events. METHODS AND RESULTS: Between 1998 and 2000, 92 patients (aged 58±15 years; ejection fraction 36±15%; coronary artery disease 71%) were treated with an ICD in combination with an endocardial lead system. Benefit of the ICD was estimated as the difference between total cardiac death and the projected death rate of fast ventricular tachyarrhythmias (>200 bpm), assuming that most fast ventricular tachyarrhythmias would have been fatal without termination by the ICD. Adverse events were classified according to European standards. The cardiac mortality rate was 5.5% and 9.8%, at one and two years respectively. The recurrence rate of fast VT (>200 bpm) was 22.4% and 30.2%, at one and two years respectively. The observed difference between cardiac death and projected death was very significant (p=0.002) and suggests a clear benefit from ICD implantation. Low ejection fraction (<35%) and NYHA class ≥II correlated with a higher projected death. The most common adverse event was inappropriate therapy (18%). CONCLUSION: The results from our small series support the existing data that especially patients with poor ejection fraction (<35%) benefit from ICD implantation. The adverse event rate was low. However, inappropriate therapy remains a matter of concern. Given the high workload of correct screening and follow-up, we expect that the actual number of centres in the Netherlands permitted to implant ICDs will be unable to cope with the widening spectrum of ICD indications.

SELECTION OF CITATIONS
SEARCH DETAIL
...