Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 2 de 2
Filter
Add more filters










Database
Language
Publication year range
1.
Article in English | MEDLINE | ID: mdl-38616358

ABSTRACT

OBJECTIVE: To assess intrarater reliability of ultrasound-determined measurements of skeletal muscle characteristics across different measurement outcomes, imaging techniques, and age groups. METHODS: 2D ultrasound images (B-mode) of the quadriceps were obtained from young (26 ± 4 year, n = 8 M, 8 F) and older (70 ± 7 year, n = 7 M, 5 F) adults on two occasions, separated by 6 ± 3 days. With participants in both standing and supine postures, images were collected from five anatomical sites along the anterior (two sites) and lateral (three sites) compartments of the thigh corresponding to 56%, 39%, and 22% (lateral only) of femur length. Images were analysed for muscle thickness, pennation angle, and echogenicity. Intraclass correlation coefficients (ICC) were used to assess reliability. RESULTS: Muscle thickness values were higher (p < 0.05) on images collected in the stand versus supine posture only for muscles of the anterior compartment, independent of age. Echogenicity values were higher (p < 0.05) in the vastus intermedius on images collected in the supine versus stand posture only in older adults. Pennation angle values were not impacted by imaging posture (p > 0.05). ICC values for thickness, echogenicity, and pennation angle were generally higher for analyses conducted on images collected in the supine versus stand posture. Imaging posture generated a greater difference in ICC values in the lateral versus anterior muscles and in older versus younger participants. CONCLUSION: Our findings suggest that participant posture during imaging impacts the absolute values and intrarater reliability of ultrasound-determined muscle characteristics in a muscle-specific fashion, and this effect is greater in older compared to younger individuals.

2.
Physiol Rep ; 9(18): e15037, 2021 09.
Article in English | MEDLINE | ID: mdl-34558207

ABSTRACT

Maximal oxygen uptake (VO2 max) declines with advancing age and is a predictor of morbidity and mortality risk. The purpose here was to assess the utility of constant load tests performed either above or below peak work rate obtained from a graded exercise test for verification of VO2 max in older adults. Twenty-two healthy older adults (9M, 13F, 67 ± 6 years, BMI: 26.3 ± 5.1 kg·m-2 ) participated in the study. Participants were asked to complete two experimental trials in a randomized, counterbalanced cross-over design. Both trials (cycle ergometer) consisted of (1) an identical graded exercise test (ramp) and (2) a constant load test at either 85% (CL85; n = 22) or 110% (CL110; n = 20) of the peak work rate achieved during the associated ramp (performed 10-min post ramp). No significant differences were observed for peak VO2 (L·min-1 ) between CL85 (1.86 ± 0.72; p = 0.679) or CL110 (1.79 ± 0.73; p = 0.200) and the associated ramp (Ramp85, 1.85 ± 0.73; Ramp110, 1.85 ± 0.57). Using the study participant's mean coefficient of variation in peak VO2 between the two identical ramp tests (2.9%) to compare individual differences between constant load tests and the associated ramp revealed 19/22 (86%) of participants achieved a peak VO2 during CL85 that was similar or higher versus the ramp, while only 13/20 (65%) of participants achieved a peak VO2 during CL110 that was similar or higher versus the ramp. These data indicate that if a verification of VO2 max is warranted when testing older adults, a constant load effort at 85% of ramp peak power may be more likely to verify VO2 max as compared to an effort at 110% of ramp peak power.


Subject(s)
Aging/physiology , Exercise Test/methods , Exercise , Oxygen Consumption , Aged , Aged, 80 and over , Biological Variation, Population , Exercise Test/standards , Female , Humans , Male , Middle Aged
SELECTION OF CITATIONS
SEARCH DETAIL
...