1.
Bone Joint J ; 105-B(12): 1279-1285, 2023 Dec 01.
Article in English | MEDLINE | ID: mdl-38035601

ABSTRACT

Aims: The use of cementless total knee arthroplasty (TKA) components has increased during the past decade. The initial design of cementless metal-backed patellar components had shown high failure rates due to many factors. The aim of this study was to evaluate the clinical results of a second-generation cementless, metal-backed patellar component of a modern design. Methods: This was a retrospective review of 707 primary TKAs in 590 patients from a single institution, using a cementless, metal-backed patellar component with a mean follow-up of 6.9 years (2 to 12). A total of 409 TKAs were performed in 338 females and 298 TKAs in 252 males. The mean age of the patients was 63 years (34 to 87) and their mean BMI was 34.3 kg/m2 (18.8 to 64.5). The patients were chosen to undergo a cementless procedure based on age and preoperative radiological and intraoperative bone quality. Outcome was assessed using the Knee Society knee and function scores and range of motion (ROM), complications, and revisions. Results: A total of 24 TKAs (3.4%) in 24 patients failed and required revision surgery, of which five were due to patellar complications (0.71%): one for aseptic patellar loosening (0.14%) and four for polyethylene dissociation (0.57%). A total of 19 revisions (2.7%) were undertaken in 19 patients for indications which did not relate to the patella: four for aseptic tibial loosening (0.57%), one for aseptic femoral loosening (0.14%), nine for periprosthetic infection (1.3%), one for popliteus impingement (0.14%), and four for instability (0.57%). Knee Society knee and function scores, and ROM, improved significantly when comparing pre- and postoperative values. Survival of the metal-backed patellar component for all-cause failure was 97.5% (95% confidence interval 94.9% to 100%) at 12 years. Conclusion: The second-generation cementless TKA design of metal-backed patellar components showed a 97.5% survival at 12 years, with polyethylene dissociation from the metal-backing being the most common cause of patellar failure. In view of the increased use of TKA, especially in younger, more active, or obese patients, these findings are encouraging at mean follow-up of seven years.


Subject(s)
Arthroplasty, Replacement, Knee , Knee Prosthesis , Male , Female , Humans , Middle Aged , Arthroplasty, Replacement, Knee/methods , Patella/surgery , Prosthesis Design , Reoperation , Metals , Polyethylene , Prosthesis Failure , Follow-Up Studies , Treatment Outcome
2.
Arthroplast Today ; 23: 101182, 2023 Oct.
Article in English | MEDLINE | ID: mdl-37712074

ABSTRACT

Background: Preoperative planning is important for successful total hip arthroplasty (THA) and has been historically performed using acetate templates. Digital software templating has been adopted for evaluating implant size, position, and alignment. Commercial software can be expensive, but free programs exist. Detroit Bone Setter (detroitbonesetter.com, Detroit, MI) is a freely available templating program, but hasn't been validated. Our study reports this program's accuracy for templating THA. Methods: Sixty-five patients undergoing THA between 2017 and 2022 at 2 hospitals were included. All cases were templated by the senior author or orthopaedic trauma fellow prospectively or retrospectively in a blinded fashion. Direct anterior or posterior approaches were used based on attending surgeon's preference. A student's t-test was used to compare means of templated vs actual implant sizes of femoral and acetabular components. Results: There was no significant difference between implanted (mean [M] = 6.4, standard deviation [SD] = 2.0) and templated femoral component sizes (M = 5.7, SD = 2.1). There was a significant difference between implanted (M = 57.0, SD = 3.9) and templated acetabular component sizes (M = 53.4, SD = 3.0). Bland-Altman testing demonstrated femoral components with positive measurement bias of 0.62, indicating slight overestimation of implant size. Acetabular component size was overestimated with positive measurement bias of 3.6 mm. Conclusions: Detroit Bone Setter is advantageous as it is freely available and supports most major company implants. It accurately templated femoral component size but consistently overestimated acetabular component size by 3.6 mm. Further studies are needed prior to recommending its routine use for templating THA when other validated methods exist. It could be used with caution when no other methods are available.

3.
J Arthroplasty ; 38(6S): S137-S144, 2023 06.
Article in English | MEDLINE | ID: mdl-36791887

ABSTRACT

BACKGROUND: Historically, 1st generation metal-backed cementless patellar implants demonstrated high failure rates due to multiple factors. The 2nd generation cementless implants were developed with purported improvements in component design and polyethylene wear characteristics. This study evaluated clinical results of a current generation cementless metal-backed patellar implant with a minimum 5-year follow-up. METHODS: One hundred and thirty-six primary total knee arthroplasties (TKAs) with metal-backed cementless patellae were compared to 183 cemented patellae with the same implant design. The cementless group mean age was 61 years (range, 40 to 81), mean body mass index (BMI) of 34.9 (range, 22.6 to 64.5), and mean follow-up of 10 years (range, 5 to 13). The cemented group mean age was 65 years (range, 32 to 89), mean BMI of 32.5 (range, 18.2 to 56.6), and mean follow-up of 10 years (range, 5 to 12). Significant demographic differences of age (P < .001), BMI (P < .01), and sex (P < .001) were found, with cementless patients being younger, heavier, and with more men. RESULTS: There were no statistical differences in non-revision procedures (P = .214), TKA revisions (P = .639), patellar revisions (P = .151), and patellar aseptic loosening (P = .737). The 10-year survivorship of the cementless metal-backed patella was 95.9% with all-cause failure as the endpoint. The 10-year survivorship of the cemented patellar component was 98.9%. CONCLUSION: This study demonstrated noninferiority of a 2nd generation HA-coated cementless metal-backed patellar implant in primary TKA compared to cemented patellae with 10-year survivorship of 95.9%. Advances in implant design and polyethylene wear properties have led to improved clinical results with metal-backed patellar components in primary TKA.


Subject(s)
Arthroplasty, Replacement, Knee , Knee Prosthesis , Patella , Aged , Humans , Male , Middle Aged , Arthroplasty, Replacement, Knee/methods , Follow-Up Studies , Metals , Patella/surgery , Polyethylene , Prosthesis Design , Prosthesis Failure , Reoperation , Treatment Outcome
SELECTION OF CITATIONS