Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 3 de 3
Filter
Add more filters










Database
Language
Publication year range
1.
Exp Eye Res ; 170: 13-19, 2018 05.
Article in English | MEDLINE | ID: mdl-29448042

ABSTRACT

The aim was to quantitatively compare retinal vascular detail as seen on optical coherence tomography angiography (OCTA) and matched histology in the human eye. 13 normal human donor eyes were used. The central retinal artery was cannulated after which human packed red blood cells were perfused through the retinal vasculature. Retinal vessels were imaged using a custom-built OCTA device during red blood cell perfusion. The eye was subsequently perfused with endothelial cell antibodies and the flat-mounted retina studied histologically using a confocal scanning laser microscope. Qualitative and quantitative comparisons of retinal vascular information as seen on OCTA and histology from the same region of interest were performed. Gradable OCTA images were acquired from 4 of 13 eyes with mean postmortem-to-OCTA imaging time of 4.5 ±â€¯1.3 h 23 pairs of OCTA-histology matched images were evaluated. The retinal arteries and veins had similar pixel intensity on OCTA images. The diameter of retinal veins was significantly greater than its paired artery on OCTA (P < 0.001). The density of vascular structures on OCTA (40.2% ±â€¯10.1%) was significantly less than matched histology (52.1% ±â€¯9.3%, P < 0.001). Mean capillary diameter on OCTA (10.2 ±â€¯2.4 µm) was significantly greater than histology (8.2 ±â€¯2.4 µm; P < 0.001). This is the first study to directly compare OCTA against histology from the same human eye. OCTA visualizes many of the vascular structures in the human retinal circulation but does not exactly match what is seen on histologic examination.


Subject(s)
Fluorescein Angiography , Retinal Vessels/anatomy & histology , Retinal Vessels/diagnostic imaging , Tomography, Optical Coherence , Aged , Aged, 80 and over , Capillaries , Female , Humans , Male , Microscopy, Confocal , Middle Aged , Perfusion , Tissue Donors , Young Adult
2.
Obstet Gynecol Sci ; 60(6): 598-601, 2017 Nov.
Article in English | MEDLINE | ID: mdl-29184870

ABSTRACT

A 74-year-old postmenopausal woman visited our gynecology clinic complaining of a palpable abdominal mass. Physical and radiological evaluation indicated that the mass exhibited features of a left ovarian neoplasm showing heterogeneous enhancement. Surgical resection was performed to confirm this suspicion. During surgery, a mass was observed only in the left ovary with no invasive growth, but adhesions to the surrounding peritoneum were seen. Given the patient's age, large mass size, and accompanying uterine myoma and right ovarian cyst, total abdominal hysterectomy with bilateral salpingo-oophorectomy was performed. The final pathologic diagnosis was dedifferentiated liposarcoma. The liposarcoma was suspected to originate from retroperitoneal adipose tissue rather than the ovary. Radiotherapy was planned if a gross lesion indicating recurrence followed 6 months later. This case required a considerable multi-disciplinary approach for diagnosis and treatment because of its ambiguous clinical and radiological findings.

3.
J Biomed Opt ; 22(3): 36007, 2017 03 01.
Article in English | MEDLINE | ID: mdl-28265647

ABSTRACT

The visibility of retinal microvasculature in optical coherence tomography angiography (OCT-A) images is negatively affected by the small dimension of the capillaries, pulsatile blood flow, and motion artifacts. Serial acquisition and time-averaging of multiple OCT-A images can enhance the definition of the capillaries and result in repeatable and consistent visualization. We demonstrate an automated method for registration and averaging of serially acquired OCT-A images. Ten OCT-A volumes from six normal control subjects were acquired using our prototype 1060-nm swept source OCT system. The volumes were divided into microsaccade-free en face angiogram strips, which were affine registered using scale-invariant feature transform keypoints, followed by nonrigid registration by pixel-wise local neighborhood matching. The resulting averaged images were presented of all the retinal layers combined, as well as in the superficial and deep plexus layers separately. The contrast-to-noise ratio and signal-to-noise ratio of the angiograms with all retinal layers (reported as average ± standard deviation ) increased from 0.52 ± 0.22 and 19.58 ± 4.04 ?? dB for a single image to 0.77 ± 0.25 and 25.05 ± 4.73 ?? dB , respectively, for the serially acquired images after registration and averaging. The improved visualization of the capillaries can enable robust quantification and study of minute changes in retinal microvasculature.


Subject(s)
Capillaries/diagnostic imaging , Fluorescein Angiography , Retina/diagnostic imaging , Tomography, Optical Coherence , Humans , Reproducibility of Results
SELECTION OF CITATIONS
SEARCH DETAIL
...