Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 1 de 1
Filter
Add more filters










Database
Language
Publication year range
1.
AJNR Am J Neuroradiol ; 41(2): 343-350, 2020 02.
Article in English | MEDLINE | ID: mdl-31974079

ABSTRACT

BACKGROUND AND PURPOSE: Spinal cord atrophy is commonly measured from cerebral MRIs, including the upper cervical cord. However, rescan intraparticipant measures have not been investigated in healthy cohorts. This study investigated technical and rescan variability in the mean upper cervical cord area calculated from T1-weighted cerebral MRIs. MATERIALS AND METHODS: In this retrospective study, 8 healthy participants were scanned and rescanned with non-distortion- and distortion-corrected MPRAGE sequences (11-50 sessions in 6-8 months), and 50 participants were scanned once with distortion-corrected MPRAGE sequences in the Day2day daily variability study. From another real-world observational cohort, we collected non-distortion-corrected MPRAGE scans from 27 healthy participants (annually for 2-4 years) and cross-sectionally from 77 participants. Statistical analyses included coefficient of variation, smallest real difference, intraclass correlation coefficient, Bland-Altman limits of agreement, and paired t tests. RESULTS: Distortion- versus non-distortion-corrected MPRAGE-derived mean upper cervical cord areas were similar; however, a paired t test showed incomparability (t = 11.0, P = <.001). Higher variability was found in the mean upper cervical cord areas calculated from an automatic segmentation method. Interrater analysis yielded incomparable measures in the same participant scans (t = 4.5, P = <.001). Non-distortion-corrected mean upper cervical cord area measures were shown to be robust in real-world data (t = -1.04, P = .31). The main sources of variability were found to be artifacts from movement, head/neck positioning, and/or metal implants. CONCLUSIONS: Technical variability in cord measures decreased using non-distortion-corrected MRIs, a semiautomatic segmentation approach, and 1 rater. Rescan variability was within ±4.4% for group mean upper cervical cord area when MR imaging quality criteria were met.


Subject(s)
Cervical Cord/anatomy & histology , Magnetic Resonance Imaging/methods , Magnetic Resonance Imaging/standards , Adult , Algorithms , Female , Humans , Image Processing, Computer-Assisted/methods , Image Processing, Computer-Assisted/standards , Male , Middle Aged , Observer Variation , Quality Control , Reproducibility of Results , Retrospective Studies
SELECTION OF CITATIONS
SEARCH DETAIL
...