Europace ; 26(4)2024 Mar 30.
Article in English | MEDLINE | ID: mdl-38513110

ABSTRACT

AIMS: Catheter ablation (CA) of post-ablation left atrial tachycardias (LATs) can be challenging. So far, pulsed field ablation (PFA) has not been compared to standard point-by-point radiofrequency current (RFC) energy for LAT ablation. To compare efficacy of PFA vs. RFC in patients undergoing CA for LAT. METHODS AND RESULTS: Consecutive patients undergoing LAT-CA were prospectively enrolled (09/2021-02/2023). After electro-anatomical high-density mapping, ablation with either a pentaspline PFA catheter or RFC was performed. Patients were matched 1:1. Ablation was performed at the assumed critical isthmus site with additional ablation, if necessary. Right atrial tachycardia (RAT) was ablated with RFC. Acute and chronic success were assessed. Fifty-six patients (n = 28 each group, age 70 ± 9 years, 75% male) were enrolled.A total of 77 AT (n = 67 LAT, n = 10 RAT; 77% macroreentries) occurred with n = 32 LAT in the PFA group and n = 35 LAT in the RFC group. Of all LAT, 94% (PFA group) vs. 91% (RFC group) successfully terminated to sinus rhythm or another AT during ablation (P = 1.0). Procedure times were shorter (PFA: 121 ± 41 vs. RFC: 190 ± 44 min, P < 0.0001) and fluoroscopy times longer in the PFA group (PFA: 15 ± 9 vs. RFC: 11 ± 6 min, P = 0.04). There were no major complications. After one-year follow-up, estimated arrhythmia free survival was 63% (PFA group) and 87% (RFC group), [hazard ratio 2.91 (95% CI: 1.11-7.65), P = 0.0473]. CONCLUSION: Pulsed field ablation of post-ablation LAT using a pentaspline catheter is feasible, safe, and faster but less effective compared to standard RFC ablation after one year of follow-up. Future catheter designs and optimization of the electrical field may further improve practicability and efficacy of PFA for LAT.

2.
J Cardiovasc Electrophysiol ; 35(1): 162-170, 2024 Jan.
Article in English | MEDLINE | ID: mdl-38009545

ABSTRACT

INTRODUCTION: Pulsed field ablation (PFA) represents a novel, nonthermal energy modality that can be applied for single-shot pulmonary vein isolation (PVI) in atrial fibrillation (AF). Comparative data with regard to deep sedation to established single-shot modalities such as cryoballoon (CB) ablation are scarce. The aim of this study was to compare a deep sedation protocol in patients receiving PVI with either PFA or CB. METHODS: Prospective, consecutive AF patients undergoing PVI with a pentaspline PFA catheter were compared to a retrospective CB-PVI cohort of the same timeframe. Study endpoints were the requirements of analgesics, cardiorespiratory stability, and sedation-associated complications. RESULTS: A total of 100 PVI patients were included (PFA n = 50, CB n = 50, mean age 66 ± 10.6, 61% male patients, 65% paroxysmal AF). Requirement of propofol, midazolam, and sufentanyl was significantly higher in the PFA group compared to CB [propofol 0.14 ± 0.04 mg/kg/min in PFA vs. 0.11 ± 0.04 mg/kg/min in CB (p = .001); midazolam 0.00086 ± 0.0004 mg/kg/min in PFA vs. 0.0006295 ± 0.0003 mg/kg/min in CB (p = .002) and sufentanyl 0.0013 ± 0.0007 µg/kg/min in PFA vs. 0.0008 ± 0.0004 µg/kg/min in CB (p < .0001)]. Sedation-associated complications did not differ between both groups (PFA n = 1/50 mild aspiration pneumonia, CB n = 0/50, p > .99). Nonsedation-associated complications (PFA: n = 2/50, 4%, CB: n = 1/50, 2%, p > .99) and procedure times (PFA 75 ± 31, CB 84 ± 32 min, p = .18) did not differ between groups. CONCLUSIONS: PFA is associated with higher sedation and especially analgesia requirements. However, the safety of deep sedation does not differ to CB ablation.


Subject(s)
Analgesia , Atrial Fibrillation , Cryosurgery , Propofol , Humans , Male , Middle Aged , Aged , Female , Atrial Fibrillation/diagnosis , Atrial Fibrillation/surgery , Retrospective Studies , Prospective Studies , Midazolam/adverse effects , Cryosurgery/adverse effects , Cryosurgery/methods
3.
J Clin Med ; 12(19)2023 Sep 29.
Article in English | MEDLINE | ID: mdl-37834948

ABSTRACT

BACKGROUND: Left atrial posterior wall isolation (LAPWI) may improve rhythm control in addition to pulmonary vein isolation (PVI) in persistent atrial fibrillation (persAF) patients undergoing catheter ablation (CA). However, LAPWI may be challenging when using thermal energy sources. OBJECTIVE: This study aimed to investigate the efficacy and safety of LAPWI performed by non-thermal pulsed field ablation (PFA) in CA for persAF. METHODS: Consecutive persAF patients from two German centers were prospectively enrolled. There were two study cohorts: (1) the LAPWI cohort, which included PFA-guided (re-)PVI with LAPWI for first-time and/or repeat ablation procedures; and (2) a comparative persAF cohort with a PFA PVI-only approach without LAPWI for first-time ablation within the same timeframe. Patients were followed up by routine Holter ECGs. RESULTS: In total, 79 persistent AF patients were included in the study: 59/79 patients were enrolled in the LAPWI cohort, including 16/59 index (27%) and 43/59 repeat ablation procedures (73%). Sixteen patients (16/79; 21%) were in the PVI-only cohort without LAPWI. Of the patients treated with LAPWI, procedure time and fluoroscopy time was 91 ± 30 min and 15 ± 7 min, respectively. The acute PVI rate was 100% in all first-time ablation patients (32 patients (16 PVI only, 16 PVI plus LAPWI), 196/196 PVs). Of the 43 re-do patients in the LAPWI cohort, re-PVI was necessary in 33% (14/43) of patients (27 PVs; 1.9 PV per-patient); in 67% (29/43), all PVs were isolated, and antral ablation of the PV ostia was performed in 48% (14/29). LAPWI was performed successfully in all 59 (100%) patients of the LAPWI cohort. Two minor complications occurred. No esophageal lesion was detected in the LAPWI cohort (n = 33/59 (56%) patients underwent endoscopy). After 354 ± 197 days of follow-up, freedom from atrial arrhythmias was 79.3% (95-CI: 62-95%) in the complete LAPWI cohort (n = 14/59 (24%) on AAD: class Ic n = 9, class III n = 5). There was no difference regarding acute procedural and clinical outcome compared to the PVI-only cohort. CONCLUSION: LAPWI guided by PFA is feasible and safe in patients undergoing CA for persAF and shows favorable outcomes. In the context of durable PVI, PFA-guided LAPWI may be an effective adjunctive treatment option.

4.
J Cardiovasc Electrophysiol ; 33(12): 2431-2443, 2022 12.
Article in English | MEDLINE | ID: mdl-36259717

ABSTRACT

INTRODUCTION: Catheter-ablation (CA) of consecutive left atrial tachycardias (LAT) can be challenging. Pulsed field ablation (PFA) yields a novel nonthermal CA technology for treatment of atrial fibrillation (AF). There is no data regarding PFA of LAT. This study sought to investigate PFA of consecutive LAT following prior CA of AF. METHODS: Consecutive patients with LAT underwent ultrahigh-density (UHDx) mapping. Subsequent to identification of the AT mechanism, PFA was performed at the assumed critical sites for LAT maintenance. Continuous ablation lines were performed if required and evaluated with pre- and post-PFA HDx-mapping. RESULTS: Fifteen patients (age 70 ± 10, male 73%) who underwent 3.6 ± 2 prior AF-CA procedures were included. The total mean procedure and fluoroscopy times were 141 ± 43 and 18 ± 10 min, respectively. All 19 of 19 (100%) LAT were successfully ablated with PFA. Two AT located at the right atria required RF-ablation. LAT were identified as localized reentry (n = 1) and macro-reentry LAT (n = 18) and targeted with PFA. All LAT terminated with PFA either to sinus rhythm (9/15) or a secondary AT (6/15 and subsequently to SR); 63% (12/19) terminated with the first PFA-application. All lines (13 roof, 11 anterior, 1 mitral) were blocked. LA-posterior-wall isolation (LAPWI) was successfully achieved when performed (10/10). AF/AT free survival was 80% (12/15) after 153 [88-207] days of follow-up. No procedure-related complications occurred. CONCLUSION: PFA of consecutive LAT is feasible and safe. Successful creation of ablation lines and LAPWI can be achieved in a short time. PFA may offer the opportunity for effective ablation of atrial arrhythmias beyond AF.


Subject(s)
Atrial Fibrillation , Catheter Ablation , Pulmonary Veins , Tachycardia, Supraventricular , Humans , Male , Middle Aged , Aged , Aged, 80 and over , Catheter Ablation/adverse effects , Catheter Ablation/methods , Tachycardia, Supraventricular/diagnosis , Tachycardia, Supraventricular/surgery , Atrial Fibrillation/diagnosis , Atrial Fibrillation/surgery , Heart Atria , Tachycardia , Treatment Outcome , Pulmonary Veins/surgery
5.
J Cardiovasc Electrophysiol ; 33(12): 2467-2472, 2022 12.
Article in English | MEDLINE | ID: mdl-36217995

ABSTRACT

INTRODUCTION: Recently, the wide-band dielectric mapping system Kodex-EPD was introduced. This study reports the first clinical experience using a novel system to guide pulmonary vein isolation (PVI) with radiofrequency (RF) ablation. METHODS AND RESULTS: The study included 20 consecutive patients undergoing de-novo PVI for symptomatic paroxysmal or persistent atrial fibrillation guided by Kodex-EPD. The primary efficacy endpoint was successful PVI. Secondary endpoints included procedural parameters and complications. In all 20 patients (mean age 68 ± 8 years, 12 male patients, paroxysmal fibrillation in 14/20 [70%] patients), PVI was successfully completed. One patient underwent additional cavo-tricuspid isthmus ablation for concomitant typical atrial flutter and one patient required additional ablation of a focal atrial tachycardia. A conventional three-dimensional image of the left atrium as well as the innovative endocardial panoramic view were used to guide catheter manipulation and ablation. Median procedure time was 115 [1st; 3rd quartile 93,75; 140] min and median total fluoroscopy time was 9.9 [9.7; 11.2] min, of which a median of 0.8 [0.6; 0.9] min was required to create left atrial maps. Complete left atrial imaging using Kodex-EPD was achieved within a median of 7.1 [5.7; 8.3] min. Median RF ablation time was 45.1 [34.6; 58.7] min. No major complications were observed. CONCLUSION: RF ablation PVI guided by Kodex-EPD seems safe and feasible. The system provides effective three-dimensional guidance for PVI.


Subject(s)
Atrial Fibrillation , Catheter Ablation , Pulmonary Veins , Radiofrequency Ablation , Humans , Male , Middle Aged , Aged , Pulmonary Veins/diagnostic imaging , Pulmonary Veins/surgery , Catheter Ablation/adverse effects , Catheter Ablation/methods , Atrial Fibrillation/diagnostic imaging , Atrial Fibrillation/surgery , Heart Atria/diagnostic imaging , Heart Atria/surgery , Treatment Outcome
6.
J Cardiovasc Electrophysiol ; 33(3): 345-356, 2022 03.
Article in English | MEDLINE | ID: mdl-34978360

ABSTRACT

BACKGROUND: Pulsed-field ablation (PFA) yields a novel ablation technology for atrial fibrillation (AF). PFA lesions promise to be highly durable, however clinical data on lesion characteristics are still limited. OBJECTIVE: This study sought to investigate PFA lesion creation with ultrahigh-density (UHDx) mapping. METHODS: Consecutive AF patients underwent PFA-based pulmonary vein isolation (PVI) using a multispline catheter (Farwave, Farapulse Inc.). Additional ablation, including left atrial posterior wall isolation (LAPWI) and mitral isthmus ablation (MI) were performed in a subset of persistent AF patients. The extent of PFA-lesions and decrease of LA-voltage were assessed with pre- and post PFA UHDx-mapping (Orion™ catheter and Rhythmia™ 3D-mapping system, Boston Scientific). RESULTS: In 20 patients, acute PVI was achieved in 80/80 PVs, LAPW isolation in 9/9 patients, MI ablation in 2/2 (procedure time: 123 ± 21.6 min, fluoroscopy time: 19.2 ± 5.5 min). UHDx-mapping subsequent to PVI revealed early PV-reconnection in five case (5/80, 6.25%). Gaps were located at the anterior-superior PV ostia and were successfully targeted with additional PFA. Repeat UHDx mapping after PFA revealed a significant decrease of voltage along the PV ostia (1.67 ± 1.36 mV vs. 0.053 ± 0.038 mV, p < .0001) with almost no complex electrogram-fractionation at the lesion border zones. PFA-catheter visualization within the mapping system was feasible in 17/19 (84.9%) patients and adequate in 92.9% of ablation sites. CONCLUSION: For the first time illustrated by UHDx mapping, PFA creates wide antral circumferential lesions and homogenous LAPW isolation with depression of tissue voltage to a minimum. Although with a low incidence, early PV reconnection can still occur also in the setting of PFA.


Subject(s)
Atrial Fibrillation , Catheter Ablation , Pulmonary Veins , Atrial Fibrillation/diagnosis , Atrial Fibrillation/surgery , Cardiac Electrophysiology , Catheter Ablation/adverse effects , Catheter Ablation/methods , Heart Atria , Humans , Pulmonary Veins/surgery , Recurrence , Treatment Outcome
8.
Arch Med Sci ; 16(5): 1022-1030, 2020.
Article in English | MEDLINE | ID: mdl-32863990

ABSTRACT

INTRODUCTION: Respiratory sinus arrhythmia (RSA) describes heart rate (HR) changes in synchrony with respiration. It is relevant for exercise capacity and mechanistically linked with the cardiac autonomic nervous system. After pulmonary vein isolation (PVI), the current therapy of choice for patients with paroxysmal atrial fibrillation (AF), the cardiac vagal tone is often diminished. We hypothesized that RSA is modulated by PVI in patients with paroxysmal AF. MATERIAL AND METHODS: Respiratory sinus arrhythmia, measured by using a deep breathing test and heart rate variability parameters, was studied in 10 patients (64 ±3 years) with paroxysmal AF presenting in stable sinus rhythm for their first catheter-based PVI. Additionally, heart rate dynamics before and after PVI were studied during sympathetic/parasympathetic coactivation by using a cold-face test. All tests were performed within 24 h before and 48 h after PVI. RESULTS: After PVI RSA (E/I difference: 7.9 ±1.0 vs. 3.5 ±0.6 bpm, p = 0.006; E/I ratio: 1.14 ±0.02 vs. 1.05 ±0.01, p = 0.003), heart rate variability (SDNN: 31 ±3 vs. 14 ±3 ms, p = 0.006; RMSSD: 17 ±2 vs. 8 ±2 ms, p = 0.002) and the HR response to sympathetic/parasympathetic coactivation (10.2 ±0.7% vs. 5.7 ±1.1%, p = 0.014) were diminished. The PVI-related changes in RSA correlated with the heart rate change during sympathetic/parasympathetic coactivation before vs. after PVI (E/I difference: r = 0.849, p = 0.002; E/I ratio: r = 0.786, p = 0.007). One patient with vagal driven arrhythmia experienced AF recurrence during follow-up (mean: 6.5 ±0.6 months). CONCLUSIONS: Respiratory sinus arrhythmia is reduced after PVI in patients with paroxysmal AF. Our findings suggest that this is related to a decrease in cardiac vagal tone. Whether and how this affects the clinical outcome including exercise capacity need to be determined.

9.
J Cardiovasc Electrophysiol ; 31(10): 2645-2652, 2020 10.
Article in English | MEDLINE | ID: mdl-32748442

ABSTRACT

INTRODUCTION: Tailored catheter ablation of atrial tachycardias (ATs) is increasingly recommended as a potentially easy treatment strategy in the era of high-density mapping (HDM). As follow-up data are sparse, we here report outcomes after HDM-guided ablation of ATs in patients with prior catheter ablation or cardiac surgery. METHODS AND RESULTS: In 250 consecutive patients (age 66.5 ± 0.7 years, 58% male) with ATs (98% prior catheter ablation, 13% prior cardiac surgery) an HDM-guided catheter ablation was performed with the support of a 64-electrode mini-basket catheter. A total of 354 ATs (1.4 ± 0.1 ATs per patient; mean cycle length 304 ± 4.3 ms; 64% macroreentry, 27% localized reentry, and 9% focal) with acute termination of 95% were targeted in the index procedure. A similar AT as in the index procedure recurred in five patients (2%) after a median follow-up time of 535 days (interquartile range (IQR) 25th-75th percentile: 217-841). Tailored ablation of reentry ATs with freedom from any arrhythmia was obtained in 53% after a single procedure and in 73% after 1.4 ± 0.4 ablation procedures (range: 1-4). A total of 228 patients (91%) were free from any arrhythmia recurrence after 210 days (IQR: 152-494) when including optimal usual care. CONCLUSIONS: Tailored catheter ablation of ATs guided by HDM has a high acute success rate. The recurrence rate of the index AT is low. In patients with extensive atrial scaring further ablation procedures need to be considered to achieve freedom from any arrhythmia.


Subject(s)
Atrial Fibrillation , Catheter Ablation , Tachycardia, Supraventricular , Aged , Atrial Fibrillation/surgery , Catheter Ablation/adverse effects , Electrophysiologic Techniques, Cardiac , Female , Humans , Male , Tachycardia, Supraventricular/diagnosis , Tachycardia, Supraventricular/surgery , Treatment Outcome
10.
Eur J Med Res ; 25(1): 4, 2020 Mar 17.
Article in English | MEDLINE | ID: mdl-32183887

ABSTRACT

BACKGROUND: Catheter ablation of non-reentrant, commonly termed "idiopathic" ventricular arrhythmias (VA) is highly effective in patients without structural heart disease (SHD). Meanwhile, the outcome of catheter ablation of these arrhythmias in patients with SHD remains unclear. This study sought to characterize the outcome of patients with and without SHD undergoing catheter ablation of non-reentrant VA. METHODS: In this single-centre study the acute and long-term outcome of 266 consecutive patients undergoing catheter ablation of non-reentrant VA was investigated. In 41.0% of patients a SHD was present (n = 109, 80.7% male, age 59.1 ± 14.7 years), 59.0% had no SHD (n = 157; 44.0% male, age 49.9 ± 16.5 years). RESULTS: Acute procedural success (absence of spontaneous or provoked VA at the end of procedure and within 48 h after the procedure) was achieved in 89.9% of patients with SHD vs. 94.3% without SHD (p = 0.238). During a mean follow-up of 34.7 ± 15.1 months a repeat catheter ablation was performed in 19.6% of patients with SHD vs. 13.0% without SHD (p = 0.179). Patients with dilated cardiomyopathy (DCM) were the most likely to require a repeat ablation procedure (32.0% of patients with DCM vs. 13.0% without SHD; p = 0.022). Periprocedural complications occurred in 5.5% of patients with SHD vs. 5.7% without SHD (p > 0.999). All complications were managed without sequelae. CONCLUSIONS: The outcome of catheter ablation of non-reentrant VA in patients with SHD appears good and is comparable to patients without SHD. A slightly higher rate of repeat ablations was observed in patients with DCM.


Subject(s)
Cardiomyopathy, Dilated/surgery , Catheter Ablation , Heart Diseases/surgery , Tachycardia, Ventricular/surgery , Adult , Cardiomyopathy, Dilated/etiology , Catheter Ablation/methods , Female , Humans , Male , Middle Aged , Tachycardia, Ventricular/etiology , Treatment Outcome
11.
J Cardiovasc Electrophysiol ; 31(5): 1051-1061, 2020 05.
Article in English | MEDLINE | ID: mdl-32107811

ABSTRACT

INTRODUCTION: The aim of this study was to investigate electrophysiological findings in patients with arrhythmia recurrence undergoing a repeat ablation procedure using ultra-high-density (UHDx) mapping following an index procedure using either contact-force (CF)-guided radiofrequency current (RFC) pulmonary vein isolation (PVI) or second-generation cryoballoon (CB) PVI for treatment of atrial fibrillation (AF). METHODS AND RESULTS: Fifty consecutive patients with recurrence of AF and/or atrial tachycardia (AT) following index CF-RFC PVI (n = 21) or CB PVI (n = 29) were included. A 64-pole mini-basket mapping catheter in combination with an UHDx-mapping system-guided ablation was used. RFC was applied using a catheter tip with three incorporated mini-electrodes. PV reconnection rates were higher after CF-RFC PVI (CF-RFC: 2.5 ± 1.3 PVs vs CB: 1.4 ± 0.9 PVs; P = .0025) and left PVs were more frequently reconnected (CF-RFC: 64% PVs vs CB: 35% PVs; P = .0077). Fractionated signals along the antral index ablation line (FS) were found in 30% of CB-PVI patients (CF-RFC: 9.5% vs CB:30%; P = .098) targeted for ablation. In five cases, FS were a critical part of maintaining consecutive AT. The main AT mechanism found during reablation (n = 45 ATs) was macroreentry (80% [36/45], CF-RFC: 78.9% vs CB: 80.8%; P = 1.0) with a variety of circuits throughout both atria. CONCLUSION: UHDx mapping is sensitive in detecting conduction gaps along the index ablation line. Left PVs are more frequently reconnected after initial CF-RFC PVI. FS are a common finding after CB PVI and can maintain certain forms of ATs. ATs after index PVI are mostly macroreentries with a broad spectrum of entities.


Subject(s)
Action Potentials , Atrial Fibrillation/surgery , Catheter Ablation , Cryosurgery , Electrophysiologic Techniques, Cardiac , Heart Rate , Pulmonary Veins/surgery , Tachycardia, Supraventricular/surgery , Aged , Atrial Fibrillation/diagnosis , Atrial Fibrillation/physiopathology , Catheter Ablation/adverse effects , Cryosurgery/adverse effects , Female , Humans , Male , Middle Aged , Predictive Value of Tests , Prospective Studies , Pulmonary Veins/physiopathology , Recurrence , Reoperation , Tachycardia, Supraventricular/diagnosis , Tachycardia, Supraventricular/physiopathology , Time Factors , Treatment Outcome
12.
J Cardiovasc Electrophysiol ; 31(1): 61-69, 2020 01.
Article in English | MEDLINE | ID: mdl-31701589

ABSTRACT

AIMS: Catheter contact and local tissue characteristics are relevant information for successful radiofrequency current (RFC)-ablation. Local impedance (LI) has been shown to reflect tissue characteristics and lesion formation during RFC-ablation. Using a novel ablation catheter incorporating three mini-electrodes, we investigated LI in relation to generator impedance (GI) in patients with ventricular tachycardia (VT) and its applicability as an indicator of effective RFC-ablation. METHODS AND RESULTS: Baseline impedance, Δimpedance during ablation and drop rate (Δimpedance/time) were analyzed for 625 RFC-applications in 28 patients with recurrent VT undergoing RFC-ablation. LI was lower in scarred (87.0 Ω [79.0-95.0]) compared to healthy myocardium (97.5 Ω ([82.75-111.50]; P = .03) while GI did not differ between scarred and healthy myocardium. ΔLI was higher (18 Ω [9.4-26.0]) for VT-terminating as compared to non-terminating RFC-ablation (ΔLI 13 Ω [8.85-18.0]; P = .03), but did not differ for ΔGI between terminating vs nonterminating RFC-ablation. Correspondingly, LI drop rate was higher for RFC-ablation terminating the VT compared with RFC-ablation not terminating the VT (0.63 Ω/s [0.52-0.76] vs 0.32 Ω [0.20-0.58]; P = .008) while there was no difference for GI drop rate. ΔLI was higher in patients with nonischemic cardiomyopathy vs patients with ischemic cardiomyopathy (16 Ω [11.0-20.0] vs 11.0 Ω [7.85-17.00]; P = .003). CONCLUSION: Our findings suggest that LI is a sensitive parameter to guide RFC-ablation in patients with VT. LI indicates differences in tissue characteristics and generally is higher in patients with nonischemic cardiomyopathy. Hence, the etiology of the underlying cardiomyopathy needs to be considered when adopting LI for monitoring catheter ablation of VT.


Subject(s)
Catheter Ablation , Electric Impedance , Tachycardia, Ventricular/surgery , Action Potentials , Aged , Cardiomyopathies/complications , Cardiomyopathies/diagnosis , Cardiomyopathies/physiopathology , Catheter Ablation/adverse effects , Female , Heart Rate , Humans , Male , Middle Aged , Risk Factors , Tachycardia, Ventricular/diagnosis , Tachycardia, Ventricular/etiology , Tachycardia, Ventricular/physiopathology , Time Factors , Treatment Outcome
13.
Cardiovasc Diagn Ther ; 9(Suppl 2): S247-S263, 2019 Oct.
Article in English | MEDLINE | ID: mdl-31737533

ABSTRACT

BACKGROUND: Ultra-high density mapping (HDM) is a promising tool in the treatment of patients with complex arrhythmias. In adults with congenital heart disease (CHD), rhythm disorders are among the most common complications but catheter ablation can be challenging due to heterogenous anatomy and complex arrhythmogenic substrates. Here, we describe our initial experience using HDM in conjunction with novel automated annotation algorithms in patients with moderate to great CHD complexity. METHODS: We studied a series of consecutive adult patients with moderate to great CHD complexity and an indication for catheter ablation due to symptomatic arrhythmia. HDM was conducted using the Rhythmia™ mapping system and a 64-electrode mini-basket catheter for identification of anatomy, voltage, activation pattern and critical areas of arrhythmia for ablation guidance. To investigate novel advanced mapping strategies, postprocedural signal processing using the Lumipoint™ software was applied. RESULTS: In 19 patients (53±3 years; 53% male), 21 consecutive ablation procedures were conducted. Procedures included ablation of atrial fibrillation (n=7; 33%), atrial tachycardia (n=11; 52%), atrioventricular accessory pathway (n=1; 5%), the atrioventricular node (n=1; 5%) and ventricular arrhythmias (n=4; 19%). A total of 23 supraventricular and 8 ventricular arrhythmias were studied with the generation of 56 complete high density maps (atrial n=43; ventricular n=11, coronary sinus n=2) and an average of 12,043±1,679 mapping points. Multiple arrhythmias were observed in n=7 procedures (33% of procedures; range of arrhythmias detected 2-4). A total range of 1-4 critical areas were defined per procedure and treated within a radiofrequency application time of 16 (interquartile range 12-45) minutes. Postprocedural signal processing using Lumipoint™ allowed rapid annotation of fractionated signals within specific windows of interest. This supported identification of a practical critical isthmus in 20 out of 27 completed atrial and ventricular tachycardia activation maps. CONCLUSIONS: Our findings suggest that HDM in conjunction with novel automated annotation algorithms provides detailed insights into arrhythmia mechanisms and might facilitate tailored catheter ablation in patients with moderate to great CHD complexity.

14.
JACC Clin Electrophysiol ; 5(4): 417-426, 2019 04.
Article in English | MEDLINE | ID: mdl-31000095

ABSTRACT

OBJECTIVES: This study sought to characterize primary left atrial tachycardia (LAT) mechanisms, electrical properties and substrate using high-density mapping. BACKGROUND: Nonfocal LAT can be found in patients without prior substrate modifying interventions. METHODS: Of 223 catheter ablation procedures for LAT 15 patients (60% male, age 74 ± 6 years) had nonfocal AT and no history of LA ablation or cardiac surgery. RESULTS: AT (mean cycle length 244 ± 32 ms) were identified as macro-re-entry (12 of 15) or localized re-entry (3 of 15). High-density electroanatomical mapping (EAM, performed in 13 patients) revealed a high proportion of low voltage areas (LVA, <0.45 mV, 41 ± 22%). Anterior LVA regions were predominantly related to the macro-re-entry and directly perpetuating the re-entrant circuit in 8 patients by formation of a conductive channel (width: 14 ± 7 mm, length: 11 ± 3 mm) between the inferior pole of the scar and the mitral valve (MV) annulus with electrophysiological features of diseased tissue. A tailored anterior ablation line successfully terminated AT in 9 patients (6 dominant circuit MV dependent, 3 dominant circuit scar dependent AT), while a lateral isthmus line was performed in 2 patients. Localized re-entries were successfully targeted by local ablation. Acute successful ablation could be achieved in 14 of 15 patients leading to a freedom from any arrhythmias in 9 of 15 patients (60%) after follow-up of 343 ± 203 days. CONCLUSIONS: Patients with nonfocal left atrial tachycardia without previous iatrogenic interventions show evidence for advanced atrial myopathy. High-density mapping revealed involvement of the anterior LA and allows for an individualized ablation approach beyond strategies usually applied in consecutive AT.


Subject(s)
Catheter Ablation , Electrophysiologic Techniques, Cardiac , Heart Atria , Tachycardia , Aged , Aged, 80 and over , Female , Heart Atria/physiopathology , Heart Atria/surgery , Humans , Male , Prospective Studies , Tachycardia/diagnosis , Tachycardia/physiopathology , Tachycardia/surgery
15.
J Cardiovasc Electrophysiol ; 30(5): 679-687, 2019 05.
Article in English | MEDLINE | ID: mdl-30821012

ABSTRACT

INTRODUCTION: Long-term efficacy and safety are uncertain in patients with cardiac implantable electronic devices (CIED) and transvenous leads (TVL) undergoing radiofrequency catheter ablation of atrial fibrillation (AF). Thus, we assessed the outcome of AF ablation in those patients during long-term follow-up using continuous atrial rhythm monitoring (CARM). METHODS AND RESULTS: A total of 190 patients (71.3 ± 10.7 years; 108 (56.8% men) were included in this study. At index procedure 81 (42.6%) patients presented with paroxysmal AF and 109 (57.4%) with persistent AF. The ablation strategy included pulmonary vein isolation in all patients and biatrial ablation of complex fractionated electrograms with additional ablation lines, if appropriate. AF recurrences were assessed by CARM- and CIED-related complications by device follow-up. After a mean follow-up of 55.4 ± 38.1 months, freedom of AF was found in 86 (61.4%) and clinical success defined as an AF burden less than or equal to 1% in 101 (72.1%) patients. Freedom of AF was reported in 74.6% and 51.9% (P = 0.006) and clinical success in 89.8% and 59.3% (P < 0.001) of patients with paroxysmal and persistent AF, respectively. In 3 of 408 (0.7%) ablation procedures, a TVL malfunction occurred within 90 days after catheter ablation. During long-term follow-up 9 (4.7%) patients showed lead dislodgement, 2 (1.1%) lead fracture, and 2 (1.1%) lead insulation defect not related to the ablation procedure. CONCLUSION: Our findings using CARM demonstrate long-term efficacy and safety of radiofrequency catheter ablation of AF in patients with CIED and TVL.


Subject(s)
Arrhythmias, Cardiac/therapy , Atrial Fibrillation/surgery , Cardiac Pacing, Artificial , Catheter Ablation , Defibrillators, Implantable , Electric Countershock/instrumentation , Pacemaker, Artificial , Pulmonary Veins/surgery , Aged , Aged, 80 and over , Arrhythmias, Cardiac/diagnosis , Arrhythmias, Cardiac/physiopathology , Atrial Fibrillation/diagnosis , Atrial Fibrillation/physiopathology , Cardiac Pacing, Artificial/adverse effects , Catheter Ablation/adverse effects , Death, Sudden, Cardiac/prevention & control , Electric Countershock/adverse effects , Equipment Failure , Female , Humans , Male , Middle Aged , Patient Safety , Progression-Free Survival , Pulmonary Veins/physiopathology , Recurrence , Retrospective Studies , Risk Assessment , Risk Factors , Time Factors
16.
Europace ; 21(Supplement_1): i34-i42, 2019 Jan 01.
Article in English | MEDLINE | ID: mdl-30801126

ABSTRACT

AIMS: A novel measure of local impedance (LI) has been found to predict lesion formation during radiofrequency current (RFC) catheter ablation. The aim of this study was to investigate the utility of this novel approach, while comparing LI to the well-established generator impedance (GI). METHODS AND RESULTS: In 25 consecutive patients with a history of atrial fibrillation, catheter ablation was guided by a 3D-mapping system measuring LI in addition to GI via an ablation catheter tip with three incorporated mini-electrodes. Local impedance and GI before and during RFC applications were studied. In total, 381 RFC applications were analysed. The baseline LI was higher in high-voltage areas (>0.5 mV; LI: 110.5 ± 13.7 Ω) when compared with intermediate-voltage sites (0.1-0.5 mV; 90.9 ± 10.1 Ω, P < 0.001), low-voltage areas (<0.1 mV; 91.9 ± 16.4 Ω, P < 0.001), and blood pool LI (91.9 ± 9.9 Ω, P < 0.001). During ablation, mean LI drop (△LI; 13.1 ± 9.1 Ω) was 2.15 times higher as mean GI drop (△GI) (6.1 ± 4.2 Ω, P < 0.001). Baseline LI correlated with △LI: a mean LI of 99.9 Ω predicted a △LI of 12.9 Ω [95% confidence interval (12.1-13.6), R2 0.41; P < 0.001]. This relationship was weak for baseline GI predicting △GI (R2 0.06, P < 0.001). Catheter movements were represented by rapid LI changes. The duration of an RFC application was not predictive for catheter-tissue coupling with no further change of △LI (P = 0.247) nor △GI (P = 0.376) during prolonged ablation. CONCLUSION: Local impedance can be monitored during ablation. Compared with the sole use of GI, baseline LI is a better predictor of impedance drops during ablation and may provide useful insights regarding lesion formation. However, further studies are needed to investigate if this novel approach is useful to guide catheter ablation.


Subject(s)
Atrial Fibrillation/physiopathology , Atrial Fibrillation/surgery , Catheter Ablation/methods , Electric Impedance , Aged , Epicardial Mapping , Female , Humans , Male , Pilot Projects , Radio Waves
17.
Clin Res Cardiol ; 107(8): 632-641, 2018 Aug.
Article in English | MEDLINE | ID: mdl-29500567

ABSTRACT

AIMS: Contact force (CF) catheters provide catheter-tissue contact information to improve outcome of pulmonary vein isolation (PVI) in paroxysmal atrial fibrillation (PAF). We evaluated different target-CF values for achievement of the additional endpoint of an unexcitable ablation line. METHODS: A total of 106 patients undergoing PVI were randomized into three groups (G) (G1: target-CF 15 g, G2: target-CF 10 g, G3: CF concealed from operator). The PVI encircling line was divided into predefined sections. Excitable tissue along the PVI-line identified by high output pacing (10 V, 2 ms) was targeted for further ablation. RESULTS: Mean average CF was 17.4 ± 4.7 g (G1) vs. 12.3 ± 6.0 g (G2) vs. 11.1 ± 6.5 g (G 3) (p < 0.001). Primary unexcitable ablation lines were found in 38.6, 19.4 and 5.7% (G1, G2, G3 respectively; G1 vs. G2 p < 0.05, G1 vs. G3 p < 0.001, G2 vs. G3 ns). Additional radiofrequency (RF)-energy to achieve unexcitability was lowest in G1 (3.6 ± 3.1 kJ vs. 8.6 ± 7.2 kJ (G2) and 10.4 ± 6.7 (G3), p ≤ 0.001, G2 vs. G3 ns) with accordingly lowest additional RF applications in G1 (3.0 ± 2.6 vs. 7.0 ± 5.4 in G2 and 8.4 ± 4.0 in G3; G1 vs. G2 and G3, p < 0.001, G 2 vs. G 3 ns). Sections along ablation lines with low initial CF were most likely to reveal excitability. Single procedure success was 81.9 vs. 73.5 vs. 71.4% (G 1, 2 and 3, p = 0.6) during 437 ± 254 day follow-up. CONCLUSION: Higher tip-to-tissue CF during PVI facilitates the achievement of an unexcitable ablation line, requiring less additional RF-energy.


Subject(s)
Atrial Fibrillation/surgery , Catheter Ablation/instrumentation , Heart Conduction System/physiopathology , Pulmonary Veins/surgery , Atrial Fibrillation/physiopathology , Body Surface Potential Mapping/methods , Equipment Design , Female , Follow-Up Studies , Humans , Male , Middle Aged , Prospective Studies , Treatment Outcome
18.
J Cardiovasc Electrophysiol ; 29(4): 537-547, 2018 04.
Article in English | MEDLINE | ID: mdl-29377448

ABSTRACT

AIMS: To evaluate the incidence of newly diagnosed intracardiac thrombi (ICT) in respect to the mode of OAC in patients undergoing cardioversion (CV). METHODS AND RESULTS: We prospectively assessed transesophageal echocardiography (TEE) and OAC therapy prior to CV in AF patients with ≥48-hour duration scheduled for CV. A total of 60 first-time ICT (4.7%) were diagnosed in 1,286 TEE, with highest rate in patients without OAC (9.6% vs. OAC 4.1%, P  =  0.009) and an apparently lower rate in nonvitamin K antagonist anticoagulants (NOAC) therapy compared to vitamin K antagonist (VKA) (2.5% vs. 5.3%, P  =  0.02). VKA therapy control 4 weeks prior to CV was overall average (time in therapeutic range 60%) and patients showed more frequently clinical characteristics and TEE parameters associated with risk for ICT. Even among patients with effective OAC therapy (uninterrupted NOAC and VKA therapy with international normalized ratio (INR) ≥2.0 for 3 weeks), ICT occurred in 2.7%, but with no difference between both groups (P  =  0.22). There was no difference between different types of NOAC. Independent predictors for ICT were history of embolism, hypertension, BMI, absence of OAC, renal function, reduced atrial appendage flow, and presence of spontaneous echo contrast. CONCLUSION: NOAC therapy seems favorable in the overall prevention of ICT, although this is likely to be caused by suboptimal VKA therapy control and differences in the overall health status between VKA and NOAC patients. ICT occurred even with effective OAC therapy suggesting individual TEE-guided cardioversion in patients at risk.


Subject(s)
Anticoagulants/administration & dosage , Atrial Fibrillation/therapy , Thrombosis/prevention & control , Administration, Oral , Aged , Anticoagulants/adverse effects , Atrial Fibrillation/diagnosis , Atrial Fibrillation/epidemiology , Echocardiography, Doppler, Pulsed , Echocardiography, Transesophageal , Electric Countershock , Electrocardiography , Female , Health Status , Humans , Incidence , International Normalized Ratio , Male , Middle Aged , Prospective Studies , Risk Factors , Thrombosis/diagnostic imaging , Thrombosis/epidemiology , Time Factors , Treatment Outcome
19.
Europace ; 20(3): 520-527, 2018 03 01.
Article in English | MEDLINE | ID: mdl-28340078

ABSTRACT

Aims: During ablation in the vicinity of the coronary arteries establishing a safe distance from the catheter tip to the relevant vessels is mandatory and usually assessed by fluoroscopy alone. The aim of the study was to investigate the feasibility of an image integration module (IIM) for continuous monitoring of the distance of the ablation catheter tip to the main coronary arteries during ablation of ventricular arrhythmias (VA) originating in the sinus of valsalva (SOV) and the left ventricular summit part of which can be reached via the great cardiac vein (GCV). Methods and results: Of 129 patients undergoing mapping for outflow tract arrhythmias from June 2014 till October 2015, a total of 39 patients (52.4 ± 18.1 years, 17 female) had a source of origin in the SOV or the left ventricular summit. Radiofrequency (RF) ablation was performed when a distance of at least 5 mm could be demonstrated with IIM. A safe distance in at least one angiographic plane could be demonstrated in all patients with a source of origin in the SOV, whereas this was not possible in 50% of patients with earliest activation in the summit area. However, using the IIM a safe position at an adjacent site within the GCV could be obtained in three of these cases and successful RF ablation performed safely without any complications. Ablation was successful in 100% of patients with an origin in the SOV, whereas VAs originating from the left ventricular summit could be abolished completely in only 60% of cases. Conclusion: Image integration combining electroanatomical mapping and fluoroscopy allows assessment of the safety of a potential ablation site by continuous real-time monitoring of the spatial relations of the catheter tip to the coronary vessels prior to RF application. It aids ablation in anatomically complex regions like the SOV or the ventricular summit providing biplane angiograms merged into the three-dimensional electroanatomical map.


Subject(s)
Arrhythmias, Cardiac/surgery , Catheter Ablation , Coronary Angiography/methods , Coronary Vessels/diagnostic imaging , Electrophysiologic Techniques, Cardiac , Heart Ventricles/surgery , Imaging, Three-Dimensional , Radiographic Image Interpretation, Computer-Assisted , Sinus of Valsalva/surgery , Action Potentials , Adult , Aged , Arrhythmias, Cardiac/diagnostic imaging , Arrhythmias, Cardiac/physiopathology , Catheter Ablation/adverse effects , Feasibility Studies , Female , Fluoroscopy , Heart Rate , Heart Ventricles/diagnostic imaging , Heart Ventricles/physiopathology , Humans , Male , Middle Aged , Predictive Value of Tests , Risk Factors , Sinus of Valsalva/diagnostic imaging , Sinus of Valsalva/physiopathology , Treatment Outcome , Ventricular Function, Left
20.
Europace ; 20(1): 43-49, 2018 01 01.
Article in English | MEDLINE | ID: mdl-27742775

ABSTRACT

Introduction: Comparative data of early recurrence rates of atrial fibrillation (ERAF) following second-generation cryoballoon (CB-G2) and radiofrequency current (RFC) ablation for pulmonary vein isolation (PVI) in paroxysmal AF (PAF) are rare. We randomized PAF patients into either PVI with CB-G2 (group 1) or PVI with a combined RFC-approach applying contact force (CF) with the endpoint of unexcitability (group 2) to investigate ERAF. Methods and results: In group 1 (n = 30), CB-G2-PVI was performed. After CF-PVI in group 2 (n = 30), bipolar pacing on the ablation line and additional ablation until unexcitability was conducted. Follow-up included 48 h of in-hospital monitoring followed by 5-day Holter ECGs 1, 2, 3, 6, 12 months postablation to evaluate ERAF. Acute PVI was reached in 100% of group 2 and in 99% of group 1. Shorter procedure durations (98.0 ± 21.9 vs. 114.3 ± 18.7 min, P < 0.05) but extended fluoroscopy times (15.4 ± 3.9 vs. 10.0 ± 4.3 min, P < 0.05) were found in the CB-G2 group. Ten non-severe complications occurred (6 vs. 4 in group 1 and 2, P = 0.73). In group 2, five patients suffered from ERAF vs. seven patients in group 1 (P = 0.67). The time until the occurrence of ERAF was shorter in group 2 (1 day (q1-q3: 1-4.5)) when compared with group 1 (22 (q1-q3: 6-54) days, P = 0.025). Conclusion: ERAF rates were equal among groups; however, they occurred earlier in the initial phase after RFC ablation when compared with CB-G2. PVI utilizing cryoablation is associated with shorter procedure durations but extended fluoroscopy time while being similarly secure.


Subject(s)
Atrial Fibrillation/surgery , Cardiac Catheters , Catheter Ablation/instrumentation , Cryosurgery/instrumentation , Pulmonary Veins/surgery , Action Potentials , Aged , Atrial Fibrillation/diagnosis , Atrial Fibrillation/physiopathology , Cardiac Pacing, Artificial , Catheter Ablation/adverse effects , Cryosurgery/adverse effects , Electrocardiography, Ambulatory , Electrophysiologic Techniques, Cardiac , Equipment Design , Female , Fluoroscopy , Germany , Heart Rate , Humans , Male , Middle Aged , Operative Time , Pilot Projects , Prospective Studies , Pulmonary Veins/physiopathology , Radiography, Interventional , Recurrence , Risk Factors , Time Factors , Treatment Outcome