Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 2 de 2
Filter
Add more filters











Database
Language
Publication year range
1.
J Knee Surg ; 35(5): 534-538, 2022 Apr.
Article in English | MEDLINE | ID: mdl-32898901

ABSTRACT

The aim of this study was to determine if the type of reamer used in tibial tunnel creation during anterior cruciate ligament (ACL) reconstruction influences the dimensions of the tunnel's outer aperture. Tibial tunnels were created in tibial saw bones by reaming over a guidewire using an 8 mm acorn or fluted reamer in an antegrade manner. Reaming was aimed either in line with the guidewire, or with 10-degree inferior/superior deviation in relation to the wire. The shape and size of the outer aperture of the tibial tunnel were compared between the two reamers. When using the acorn reamer, a 10-degree deviation in relation to the guidewire resulted in minimal change in outer aperture length (mean 13.6 vs. 15.6 mm, p = 0.11) and width (11.6 vs. 11.1 mm, p = 0.51). However, when using the fluted reamer, although the aperture width showed no substantial change with reamer/guidewire deviation (11.4 vs. 11.2 mm, p = 0.71), the mean length almost doubled (14.7 vs. 28.1 mm, p = 0.002). The use of a fluted reamer when reaming the tibial tunnel creates a distal aperture which is inconsistently sized, larger, and of oblong shape compared with an acorn-shaped reamer. This should be taken in consideration when using a fluted reamer for creating the tibial tunnel in ACL reconstruction.


Subject(s)
Anterior Cruciate Ligament Injuries , Anterior Cruciate Ligament Reconstruction , Anterior Cruciate Ligament/surgery , Anterior Cruciate Ligament Injuries/surgery , Anterior Cruciate Ligament Reconstruction/methods , Femur/surgery , Humans , Tibia/surgery
2.
Eur J Orthop Surg Traumatol ; 31(5): 989-993, 2021 Jul.
Article in English | MEDLINE | ID: mdl-34110468

ABSTRACT

INTRODUCTION: Personal protective equipment (PPE) may protect health-care workers from COVID-19 infection and limit nosocomial spread to vulnerable hip fracture patients. METHODS: We performed a cross-sectional survey amongst orthopaedic trainees to explore PPE practice in 19 hospitals caring for hip fracture patients in the North West of England. RESULTS: During the second wave of the pandemic, 14/19 (74%) hospitals experienced an outbreak of COVID-19 amongst staff or patients on the orthopaedic wards. An FFP3 respirator mask was used by doctors in only 6/19 (32%) hospitals when seeing patients with COVID-19 and a cough and in 5/19 (26%) hospitals when seeing asymptomatic patients with COVID-19. A COVID-19 outbreak was reported in 11/13 (85%) orthopaedic units where staff wore fluid resistant surgical masks compared to 3/6 (50%) units using an FFP3 respirator mask (RR 1.69, 95% CI 0.74-3.89) when caring for symptomatic patients with COVID-19. Similarly, a COVID-19 outbreak was reported in more orthopaedic units caring for asymptomatic patients with COVID-19 where staff wore fluid resistant surgical masks (12/14 (86%)) as compared to an FFP3 respirator mask (2/5 (40%)) (RR 2.14, 95% CI 0.72-6.4). CONCLUSION: Urgent re-evaluation of PPE use is required to reduce nosocomial spread of COVID-19, amongst highly vulnerable patients with hip fracture.


Subject(s)
COVID-19/transmission , Cross Infection/transmission , Hip Fractures/complications , Orthopedics , Cross-Sectional Studies , England , Humans , Masks , Personal Protective Equipment , Ventilators, Mechanical
SELECTION OF CITATIONS
SEARCH DETAIL