Nefrología (Madr.) ; 27(supl.3): 187-191, 2007. ilus, tab
Article in Es | IBECS | ID: ibc-057400

ABSTRACT

No disponible


Extracorporeal circuits for the management of acute renal failure entail a great deal of complications. The placement of a large double lumen central venous catheter (CVC) to provide enough blood flow together with the necessity of a continuous anticoagulation are the cause of the majority of the adverse events, such as puncture site bleeding, vascular complications, systemic hemorrhage, venous thrombosis and CVC-related infections. Hydro-electrolytic abnormalities regarding the use of fluids for reposition and dialysis, are frequently observed; mainly hypokalemia and hypophosphatemia. Liquids with lactate can produce hyperlactatemia or even exacerbate the lactic acidosis when lactate metabolism is altered


Subject(s)
Humans , Renal Replacement Therapy/adverse effects , Acute Kidney Injury/therapy , Anticoagulants/therapeutic use , Hemodialysis Solutions/analysis , Catheters, Indwelling/adverse effects