Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 12 de 12
Filter
Add more filters










Publication year range
1.
Ann Dermatol ; 35(Suppl 2): S247-S251, 2023 Nov.
Article in English | MEDLINE | ID: mdl-38061714

ABSTRACT

Tinea capitis is an infection of the scalp hair follicles and surrounding skin that primarily occurs in prepubertal children. Microsporum canis remains the most common pathogen causing tinea capitis in Asian countries, including South Korea, although the causative organism of this condition varies across geographical regions and time periods. Systemic antifungal agents are the mainstay treatments for tinea capitis; however, the therapeutic responses to antifungal drugs may vary depending on the causative species, and treatment failure may occur owing to drug resistance. Although dermatophytosis resistant to clinical treatment have been increasingly encountered, recalcitrant tinea capitis cases have rarely been reported. Herein, we report three cases of tinea capitis caused by M. canis in children. All three patients showed unsatisfactory clinical responses to prolonged courses of oral terbinafine or itraconazole without achieving mycological cure; however, they were successfully treated with oral griseofulvin. Although griseofulvin is not currently available or licensed for use in many countries, including South Korea, it is one of the most effective agents against Microsporum species and remains the most widely used first-line treatment for tinea capitis in children, based on dermatology textbooks and reliable treatment guidelines.

2.
Ann Dermatol ; 33(6): 572-576, 2021 Dec.
Article in English | MEDLINE | ID: mdl-34858010

ABSTRACT

Nontuberculous mycobacteria are ubiquitous environmental organisms that are rare pathogens in immunocompetent individuals. However, cutaneous nontuberculous mycobacteria infections have been increasingly associated with invasive procedures, including surgery, liposuction, filler injection, intramuscular injection, mesotherapy, piercing, acupuncture, and cupping therapy. Herein, we report the first case of cutaneous nontuberculous mycobacteria infection caused by the East-Asian traditional treatment 'Gua Sha', also known as scraping, coining or spooning in English. A 35-year-old healthy female presented with widespread, painful skin nodules and pustules on her upper and lower extremities that had developed after Gua Sha treatment for body contouring. Histopathologic examination of the lesions revealed granulomatous inflammation in the dermis and the culture isolates were identified as Mycobacterium massiliense with molecular identification. The patient was successfully treated with intermittent incision and drainage of persistent nodules and oral clarithromycin based on antimicrobial susceptibility testing. We recommend implementation of a standard safety protocol for Gua Sha practitioners to minimize the risk of infection transmission.

7.
Technol Health Care ; 27(S1): 445-454, 2019.
Article in English | MEDLINE | ID: mdl-31045559

ABSTRACT

BACKGROUND: This paper describes the design and implementation of a dual-coil type electromagnetic actuator for implantable bone conduction hearing devices. OBJECTIVE: The structure of the proposed actuator was designed to generate maximum Lorentz force via the dual-coil method with a closed magnetic circuit. To satisfy the indications required by implantable bone conduction hearing devices, high output was generated within a specific frequency range using a vibrational membrane with a cantilever. METHODS: The structure of the membrane consists of a fixed ring, a circular plate, and two cantilevers connected symmetrically. Variable elements of the vibrational membrane affecting the actuator frequency characteristics were analyzed through mathematical modeling and finite element analysis, based on the analysis used to derive the optimum structure of the vibrational membrane. The components of the actuator were fabricated through chemical etching and computer numerical control process, and the bone conduction actuator was fabricated through the precision assembly process. RESULTS: The output characteristics of the implemented actuator were measured using a laser Doppler vibrometer. As a result of measurement, the proposed actuator generated mechanical resonance at 1.2 kHz. CONCLUSIONS: By comparing the measured results with the finite element analysis results, we confirmed the validity of the proposed actuator design.


Subject(s)
Bone Conduction , Cochlear Implants , Electromagnetic Phenomena , Equipment Design , Finite Element Analysis , Humans , Prostheses and Implants , Vibration
9.
J Epilepsy Res ; 6(1): 28-30, 2016 Jun.
Article in English | MEDLINE | ID: mdl-27390677

ABSTRACT

Subacute encephalopathy with seizures in chronic alcoholism syndrome is a rare clinical manifestation in patients with chronic alcohol abuse. We report the case of a patient with chronic alcoholism who presented with partial nonconvulsive status epilepticus associated with a thalamic lesion.

10.
Biomed Mater Eng ; 24(6): 2503-10, 2014.
Article in English | MEDLINE | ID: mdl-25226951

ABSTRACT

Since the 1980's, various types of implantable hearing aids using unique means for delivering acoustic power to the inner ear have been developed. Recently, implantable hearing aids that stimulate the round window by the middle ear transducer have received great attention because it reduces loading effect at the ossicular chain. In this study, we have implemented a direct install 3-pole type EM transducer in round window niche for implantable middle ear hearing aid. The 3-pole type EM transducer consists of two permanent magnets and three coils and exhibit structural features that minimize leakage flux, thereby permitting high efficiency and low magnetic field interference. The stapes velocity was measured using a laser Doppler vibrometer in response to the round window stimulation from the transducer. To verify the usefulness of the 3-pole type EM transducer, we compared the stapes vibration characteristics produced by the transducer and those from a sound source. The magnitude of stapes velocity due to the round window stimulation at 1 mArms was equivalent to that of stapes velocity at 94 dB SPL sound stimulation. Thus, the evaluation study shows that the 3-pole type EM transducer is suitable for implantable hearing devices.


Subject(s)
Bone Conduction/physiology , Cochlear Implants , Hearing Aids , Micro-Electrical-Mechanical Systems/instrumentation , Round Window, Ear/physiology , Temporal Bone/physiology , Transducers , Aged, 80 and over , Equipment Design , Equipment Failure Analysis , Female , Humans , In Vitro Techniques , Magnetics/instrumentation , Male , Vibration
11.
Biomed Mater Eng ; 24(6): 3685-91, 2014.
Article in English | MEDLINE | ID: mdl-25227083

ABSTRACT

The microphone in a fully implantable hearing device (FIHD) is generally implanted under the skin covering the temporal bone. However, the implanted microphone can be affected by the skin, which causes both sound attenuation and distortion, particularly at high frequencies. As the degree of attenuation and distortion through the skin is severe, speech quality evaluation parameters are needed for the received signal when designing an implantable microphone. However, the performance of most implantable microphones is only assessed based on the sensitivity and frequency response. Thus, practical indicators based on human auditory characteristics are needed for an objective evaluation of the performance of implantable microphones. In this study, a subcutaneously implantable microphone was designed, and its frequency response investigated using an in vivo experiment. Plus, to evaluate the objective indicators, the speech quality of the signals measured by the implanted microphone was calculated using a MATLAB program, and the indicators compared before and after implantation.


Subject(s)
Hearing Aids , Ossicular Prosthesis , Speech Production Measurement/instrumentation , Transducers , Animals , Equipment Design , Equipment Failure Analysis , Guinea Pigs
12.
Biomed Mater Eng ; 24(1): 405-11, 2014.
Article in English | MEDLINE | ID: mdl-24211922

ABSTRACT

Round window placement of a 3-coil transducer offers a new approach for coupling an implantable hearing aid to the inner ear. The transducer exhibits high performance at low-frequencies. One remarkable feature of the 3-coil transducer is that it minimizes leakage flux. Thus, the transducer, which consists of two permanent magnets and three coils, can enhance vibrational displacement. In human temporal bones, stapes vibration was observed by laser Doppler vibrometer in response to round window stimulation using the 3-coil transducer. Coupling between the 3-coil transducer and the round window was connected by a wire-rod. The stimulation created stapes velocity when the round window stimulated. Performance evaluation was conducted by measuring stapes velocity. To verify the performance of the 3-coil transducer, stapes velocity for round window and tympanic membrane stimulation were compared, respectively. Stapes velocity by round window stimulation using the 3-coil transducer was approximately 14 dB higher than that achieved by tympanic membrane stimulation. The study shows that 3-coil transducer is suitable for implantable hearing aids.


Subject(s)
Hearing Aids , Round Window, Ear/pathology , Stapes/physiology , Temporal Bone/physiology , Aged, 80 and over , Equipment Design , Humans , Laser-Doppler Flowmetry , Magnetics , Male , Middle Aged , Reproducibility of Results , Transducers , Tympanic Membrane/pathology , Vibration
SELECTION OF CITATIONS
SEARCH DETAIL
...