Blood Coagul Fibrinolysis ; 33(7): 402-411, 2022 Oct 01.
Article in English | MEDLINE | ID: mdl-35867944

ABSTRACT

Coagulation factor testing is commonly performed within haemostasis laboratories, either to assess for bleeding disorders, such as haemophilia, or to investigate unexplained prolongation in routine coagulation assays. The aim of this evaluation was to harmonize procedures and normal reference ranges (NRRs) for investigation of coagulation factors on the ACL TOP 50 family of instruments in a large laboratory network. We employed comparative evaluations using newly installed ACL TOPs 550 and 750 and HemosIL reagents vs. existing 'reference' instrumentation and reagents, predominantly Stago and Siemens, as well as assessment of factor sensitivity in routine coagulation assays, prothrombin time (PT) and activated partial thromboplastin time (APTT). Also, establishment of coagulation factor NRRs using normal plasma samples. HemosIL factor assays showed good comparability with the existing reference methods ( R > 0.9). Factor sensitivity for PT and APTT assays were acceptable at around 30 U/dl. NRRs were established and harmonized across the laboratory network. This evaluation of factor testing on ACL TOP 50 Family instruments identified overall acceptable performance using Werfen reagents and enabled harmonization of coagulation factor testing in our large network.


Subject(s)
Blood Coagulation Factors , Laboratories , Blood Coagulation Tests/methods , Humans , Partial Thromboplastin Time , Prothrombin Time/methods
2.
Int J Lab Hematol ; 44(5): 934-944, 2022 Oct.
Article in English | MEDLINE | ID: mdl-35754202

ABSTRACT

INTRODUCTION: The platelet function analyzer (PFA) is a popular platelet function screening instrument, highly sensitive to von Willebrand disease (VWD) and to aspirin therapy, with moderate sensitivity to defects in platelet function and/or deficiencies in platelet number. There are two models, the original PFA-100 and the contemporary PFA-200. Normal reference ranges (NRRs) provided by the manufacturer are the same for both models, instead being based on the type of test cartridge, for which there are two main ones: collagen/epinephrine (C/Epi) and collagen/adenosine diphosphate (C/ADP). METHODS: Comparative evaluations of PFA testing and reporting in six different sites of a large pathology network, aiming to harmonize NRRs and test reporting across all network sites. A separate comparative study of testing a range of samples (n > 150) on a PFA-100 versus that on a PFA-200. Review of contemporary literature. RESULTS: Each site was identified to have a different reporting NRR, which after consolidating data permitted establishment of an agreed harmonized NRR for use across the network (C/Epi: 90-160; C/ADP: 70-124; based on n > 180). Similarly, each site reported and interpreted results in different ways, and after discussion and consolidation, a harmonized approach to interpretation and reporting was achieved. The separate comparative study of PFA-100 versus PFA-200 testing confirmed instrument equivalence. CONCLUSION: We achieved harmonized NRRs and reporting for PFA testing across a large pathology network. Our approach may be useful for other laboratory networks wishing to harmonize PFA testing.


Subject(s)
Platelet Function Tests , von Willebrand Diseases , Adenosine Diphosphate , Blood Platelets , Collagen , Epinephrine , Humans , Sensitivity and Specificity , von Willebrand Diseases/diagnosis
3.
Int J Lab Hematol ; 44(3): 654-665, 2022 Jun.
Article in English | MEDLINE | ID: mdl-35234361

ABSTRACT

INTRODUCTION: Lupus anticoagulant (LA) testing is commonly performed within hemostasis laboratories, and the ACL TOP 50 family of instruments represent a new "single platform" of hemostasis instrumentation. Our aim was to evaluate these instruments and manufacturer reagents or alternatives for utility in LA testing. METHODS: Comparative evaluations of LA testing using newly installed ACL TOPs 550 and 750 as well as comparative assessments with existing "reference," predominantly Stago, instrumentation, and reagents. Evaluations comprised both dilute Russell viper venom time (dRVVT) and activated partial thromboplastin time (APTT)-based assays. Establishment of normal reference ranges (NRR). RESULTS: The HemosIL dRVVT-based assays showed good comparability with the existing Stago reference method (R > 0.9) and could be considered as verified as fit for purpose. A variety of APTT assays was additionally evaluated for LA utility, and we identified from the assessment good utility of a non-Werfen solution in Hyphen BioMed Cephen reagents. NRR were established based on ≥120 normal individual plasma samples. CONCLUSION: This evaluation of LA reagents on ACL TOP 50 Family instruments identified overall acceptable performance of both dRVVT (Werfen solution) and APTT (non-Werfen solution) to enable harmonization of LA testing in our large network.


Subject(s)
Antiphospholipid Syndrome , Lupus Coagulation Inhibitor , Blood Coagulation Tests/methods , Humans , Laboratories , Partial Thromboplastin Time , Prothrombin Time/methods
4.
Eur J Pharm Sci ; 166: 105940, 2021 Nov 01.
Article in English | MEDLINE | ID: mdl-34265407

ABSTRACT

Nifurtimox is approved in Chagas disease and has been used in endemic countries since the 1960s. Nifurtimox, available as a 120 mg tablet, is administered with food typically three times daily, and dose is adjusted for age and bodyweight. Accurately or reproducibly fragmenting the 120 mg tablet for dose adjustment in young children and those with low bodyweight is problematic. Based on the existing tablet formulation, new nifurtimox 30 mg and 120 mg tablets have been developed in a format that can be divided accurately into 15 mg and 60 mg fragments. In adults with chronic Chagas disease, we investigated whether nifurtimox bioavailability is affected by tablet dissolution rate, and whether different diets affect nifurtimox bioavailability. In an open-label, three-period cross-over study (n=36; ClinicalTrials.gov, NCT03350295), patients randomly received three 30 mg tablet formulations (slow, medium, or fast dissolution; a 4 × 30 mg dose of one formulation per period). In an open-label, four-period cross-over study (n=24; ClinicalTrials.gov, NCT03334838) patients randomly fasted or received one of three meal types (high-fat/high-calorie, low-fat, dairy-based) before ingesting nifurtimox (a 4 × 30 mg dose per period). Acceptance criteria for no difference between groups were 90% confidence intervals (CIs) of exposure ratios in the range 0.8-1.25. Nifurtimox bioavailability was unaffected by tablet dissolution kinetics. Ratios of area under the curve at final assessment (AUC(0-tlast) [90% CI]) were: fast/medium dissolution, 1.061 (0.990-1.137); slow/medium dissolution, 0.964 (0.900-1.033); fast/slow dissolution, 1.100 (1.027-1.179). Compared with a fasting state, nifurtimox bioavailability increased by 73% after a high-fat/high-calorie meal (AUC(0-tlast) ratio [90% CI], 1.732 [1.581-1.898]); smaller increases were seen with the other meal types (low-fat: 1.602 [1.462-1.755]; dairy-based: 1.340 [1.222-1.468]). Although type of diet can affect bioavailability, taking nifurtimox with food is most important.


Subject(s)
Biological Products , Nifurtimox , Administration, Oral , Adult , Area Under Curve , Biological Availability , Child , Child, Preschool , Cross-Over Studies , Fasting , Humans , Quality Control , Tablets , Therapeutic Equivalency
5.
Clin Chem Lab Med ; 59(10): 1709-1718, 2021 09 27.
Article in English | MEDLINE | ID: mdl-34116591

ABSTRACT

OBJECTIVES: Thrombophilia testing is commonly performed within hemostasis laboratories, and the ACL TOP 50 family of instruments represent a new 'single platform' of hemostasis instrumentation. The study objective was to evaluate these instruments and manufacturer reagents for utility of congenital thrombophilia assays. METHODS: Comparative evaluations of various congenital thrombophilia assays (protein C [PC], protein S [PS], antithrombin [AT], activated protein C resistance [APCR]) using newly installed ACL TOPs 550 and 750 as well as comparative assessments with existing, predominantly STAGO, instrumentation and reagents. Verification of manufacturer assay normal reference ranges (NRRs). RESULTS: HemosIL PC and free PS assays showed good comparability with existing Stago methods (R>0.9) and could be considered as verified as fit for purpose. HemosIL AT showed high relative bias with samples from patients on direct anti-Xa agents, compromising utility. Manufacturer NRRs for PC, PS and AT were verified with minor variance. Given the interference with direct anti-Xa agents, an alternate assay (Hyphen) was evaluated for AT, and the NRR also verified. The HemosIL Factor V Leiden (APC Resistance V) evidenced relatively poor performance compared to existing assays, and could not be adopted for use in our network. CONCLUSIONS: This evaluation of HemosIL reagents on ACL TOP 50 family instruments identified overall acceptable performance of only two (PC, free PS) of four thrombophilia assays, requiring use of third-party reagents on ACL instruments for the other two assays (AT, APCR).


Subject(s)
Activated Protein C Resistance , Thrombophilia , Blood Coagulation Tests , Factor V/analysis , Humans , Laboratories , Protein C/analysis , Thrombophilia/diagnosis
6.
Am J Clin Pathol ; 156(4): 661-678, 2021 Sep 08.
Article in English | MEDLINE | ID: mdl-33891005

ABSTRACT

OBJECTIVES: To verify a single platform of hemostasis instrumentation, the ACL TOP 50 Family, comprising 350, 550, and 750 instruments, across a large network of 60 laboratories. METHODS: Comparative evaluations of instrument classes (350 vs 550 and 750) were performed using a large battery of test samples for routine coagulation tests, comprising prothrombin time/international normalized ratio, activated partial thromboplastin time (APTT), thrombin time, fibrinogen and D-dimer, and using HemosIL reagents. Comparisons were also made against existing equipment (Diagnostica Stago Satellite, Compact, and STA-R Evolution) and existing reagents to satisfy national accreditation standards. Verification of manufacturer normal reference ranges (NRRs) and generation of an APTT heparin therapeutic range were undertaken. RESULTS: The three instrument types were verified as a single instrument class, which will permit standardization of methods and NRRs across all instruments (n = 75) to be deployed in 60 laboratories. In particular, ACL TOP 350 test result data were similar to ACL TOP 550 and 750 and showed no to limited bias. All manufacturer NRRs were verified with occasional minor variance. CONCLUSIONS: This ACL TOP 50 Family (350, 550, and 750) verification will enable harmonization of routine coagulation across all laboratories in the largest public pathology network in Australia.


Subject(s)
Blood Coagulation Tests/instrumentation , Laboratories/standards , Pathology/instrumentation , Humans , International Normalized Ratio , Partial Thromboplastin Time , Prothrombin Time
8.
Microbiome ; 6(1): 134, 2018 08 02.
Article in English | MEDLINE | ID: mdl-30071904

ABSTRACT

BACKGROUND: As the gut microbiota contributes to metabolic health, it is important to determine specific diet-microbiota interactions that influence host metabolism. Bile acids and dietary fat source can alter phenotypes of diet-induced obesity, but the interplay with intestinal microorganisms is unclear. Here, we investigated metabolic consequences of diets enriched in primary bile acids with or without addition of lard or palm oil, and studied gut microbiota structure and functions in mice. RESULTS: In combination with bile acids, dietary lard fed to male C57BL/6N mice for a period of 8 weeks enhanced fat mass accumulation in colonized, but not in germ-free mice when compared to palm oil. This was associated with impaired glucose tolerance, lower fasting insulin levels, lower counts of enteroendocrine cells, fatty liver, and elevated amounts of hepatic triglycerides, cholesteryl esters, and monounsaturated fatty acids. Lard- and bile acid-fed mice were characterized by shifts in dominant gut bacterial communities, including decreased relative abundances of Lachnospiraceae and increased occurrence of Desulfovibrionaceae and the species Clostridium lactatifermentans and Flintibacter butyricus. Metatranscriptomic analysis revealed shifts in microbial functions, including lipid and amino acid metabolism. CONCLUSIONS: Caution is required when interpreting data from diet-induced obesity models due to varying effects of dietary fat source. Detrimental metabolic consequences of a diet enriched with lard and primary bile acids were dependent on microbial colonization of the host and were linked to hepatic lipid rearrangements and to alterations of dominant bacterial communities in the cecum.


Subject(s)
Bacteria/classification , Bile Acids and Salts/analysis , Diet, High-Fat/adverse effects , Gastrointestinal Microbiome/drug effects , Obesity/chemically induced , Amino Acids/metabolism , Animals , Bacteria/drug effects , Bacteria/genetics , DNA, Bacterial/genetics , DNA, Ribosomal/genetics , Dietary Fats/adverse effects , Gene Expression Profiling , Lipid Metabolism , Male , Mice , Mice, Inbred C57BL , Obesity/metabolism , Palm Oil/adverse effects , Phylogeny , RNA, Ribosomal, 16S/genetics
9.
Semin Thromb Hemost ; 43(1): 75-91, 2017 Feb.
Article in English | MEDLINE | ID: mdl-27978590

ABSTRACT

von Willebrand disease (VWD) was first described nearly a century ago in 1924 by Erik Adolf von Willebrand. Diagnostic testing at the time was very limited and it was not until the mid to late 1900s that more tests became available to assist with the diagnosis and classification of VWD. Two of these tests are based on ristocetin, one being ristocetin-induced platelet aggregation (RIPA) and the other the von Willebrand factor (VWF) ristocetin cofactor assay (VWF:RCo). The VWF:RCo assay provides functional assessment of in vitro VWF binding to the platelet glycoprotein (Gp) complex, GPIb-IX-V. Despite some advancements and newer technologies utilizing the principles of the original VWF:RCo assay, the original assay is still referred to as the gold standard for measurement of VWF activity. This article will review the history of VWD diagnostic assays, including RIPA and VWF:RCo over the past 40 years, as well as the newer assays that measure platelet binding with or without ristocetin, and which have been developed with the aim to potentially replace platelet-based ristocetin-dependent assays.


Subject(s)
Blood Platelets/metabolism , Ristocetin/therapeutic use , von Willebrand Diseases/drug therapy , Humans , Platelet Aggregation/drug effects , Ristocetin/administration & dosage , von Willebrand Diseases/diagnosis
10.
Anal Bioanal Chem ; 409(5): 1231-1245, 2017 Feb.
Article in English | MEDLINE | ID: mdl-27822648

ABSTRACT

Bile acids are important signaling molecules that regulate cholesterol, glucose, and energy homoeostasis and have thus been implicated in the development of metabolic disorders. Their bioavailability is strongly modulated by the gut microbiota, which contributes to generation of complex individual-specific bile acid profiles. Hence, it is important to have accurate methods at hand for precise measurement of these important metabolites. Here, a rapid and sensitive liquid chromatography-tandem mass spectrometry (LC-MS/MS) method for simultaneous identification and quantitation of primary and secondary bile acids as well as their taurine and glycine conjugates was developed and validated. Applicability of the method was demonstrated for mammalian tissues, biofluids, and cell culture media. The analytical approach mainly consists of a simple and rapid liquid-liquid extraction procedure in presence of deuterium-labeled internal standards. Baseline separation of all isobaric bile acid species was achieved and a linear correlation over a broad concentration range was observed. The method showed acceptable accuracy and precision on intra-day (1.42-11.07 %) and inter-day (2.11-12.71 %) analyses and achieved good recovery rates for representative analytes (83.7-107.1 %). As a proof of concept, the analytical method was applied to mouse tissues and biofluids, but especially to samples from in vitro fermentations with gut bacteria of the family Coriobacteriaceae. The developed method revealed that the species Eggerthella lenta and Collinsella aerofaciens possess bile salt hydrolase activity, and for the first time that the species Enterorhabdus mucosicola is able to deconjugate and dehydrogenate primary bile acids in vitro.


Subject(s)
Bacteria/metabolism , Bile Acids and Salts/analysis , Chromatography, Liquid/methods , Intestines/microbiology , Spectrometry, Mass, Electrospray Ionization/methods , Tandem Mass Spectrometry/methods , Animals , Bile Acids and Salts/metabolism , Calibration , Fermentation , Liquid-Liquid Extraction , Mice , Reproducibility of Results , Solid Phase Extraction
12.
Sci Rep ; 6: 34337, 2016 10 05.
Article in English | MEDLINE | ID: mdl-27703179

ABSTRACT

Pathogen infections, autoimmune diseases, and chronic inflammatory disorders are associated with systemic antibody responses from the host immune system. Disease-specific antibodies can be important serum biomarkers, but the identification of antigens associated with specific immune reactions is challenging, in particular if complex communities of microorganisms are involved in the disease progression. Despite promising new diagnostic opportunities, the discovery of these serological markers becomes more difficult with increasing complexity of microbial communities. In the present work, we used a metagenomic M13 phage display approach to select immunogenic oligopeptides from the gut microbiome of transgenic mice suffering from chronic ileitis. We constructed three individual metaproteome phage display libraries with a library size of approximately 107 clones each. Using serum antibodies, we selected and validated three oligopeptides that induced specific antibody responses in the mouse model. This proof-of-concept study provides the first successful application of functional metaproteome display for the study of protein-protein interactions and the discovery of potential disease biomarkers.


Subject(s)
Gastrointestinal Microbiome , Ileitis , Metagenome , Oligopeptides/genetics , Peptide Library , Proteome/genetics , Animals , Chronic Disease , Ileitis/genetics , Ileitis/metabolism , Ileitis/microbiology , Mice , Mice, Transgenic , Oligopeptides/metabolism , Proteome/metabolism
13.
Nat Microbiol ; 1(10): 16131, 2016 08 08.
Article in English | MEDLINE | ID: mdl-27670113

ABSTRACT

Intestinal bacteria influence mammalian physiology, but many types of bacteria are still uncharacterized. Moreover, reference strains of mouse gut bacteria are not easily available, although mouse models are extensively used in medical research. These are major limitations for the investigation of intestinal microbiomes and their interactions with diet and host. It is thus important to study in detail the diversity and functions of gut microbiota members, including those colonizing the mouse intestine. To address these issues, we aimed at establishing the Mouse Intestinal Bacterial Collection (miBC), a public repository of bacterial strains and associated genomes from the mouse gut, and studied host-specificity of colonization and sequence-based relevance of the resource. The collection includes several strains representing novel species, genera and even one family. Genomic analyses showed that certain species are specific to the mouse intestine and that a minimal consortium of 18 strains covered 50-75% of the known functional potential of metagenomes. The present work will sustain future research on microbiota-host interactions in health and disease, as it will facilitate targeted colonization and molecular studies. The resource is available at www.dsmz.de/miBC.


Subject(s)
Bacteria/isolation & purification , Biodiversity , Biological Specimen Banks , Gastrointestinal Microbiome/physiology , Host Specificity , Intestines/microbiology , Animals , Bacteria/classification , Bacteria/genetics , Gastrointestinal Microbiome/genetics , Genome, Bacterial , Mice
14.
15.
J Pharm Sci ; 104(12): 4082-4092, 2015 Dec.
Article in English | MEDLINE | ID: mdl-26344941

ABSTRACT

Tablet coating is a common unit operation in the pharmaceutical industry, during which a coating layer is applied to tablet cores. The coating uniformity of tablets in a batch is especially critical for active coating, that is, coating that contains an active pharmaceutical ingredient. In recent years, discrete element method (DEM) simulations became increasingly common for investigating tablet coating. In this work, DEM was applied to model an active coating process as closely as possible, using measured model parameters and non-spherical particles. We studied how operational conditions (rotation speed, fill level, number of nozzles, and spray rate) influence the coating uniformity. To this end, simulation runs were planned and interpreted according to a statistical design of (simulation) experiments. Our general goal was to achieve a deeper understanding of the process in terms of residence times and dimensionless scaling laws. With that regard, the results were interpreted in light of analytical models. The results were presented at various detail levels, ranging from an overview of all variations to in-depth considerations. It was determined that the biggest uniformity improvement in a realistic setting was achieved by increasing the number of spray nozzles, followed by increasing the rotation speed and decreasing the fill level.


Subject(s)
Tablets/chemistry , Drug Compounding/methods , Models, Theoretical
16.
Int J Syst Evol Microbiol ; 65(Pt 3): 870-878, 2015 Mar.
Article in English | MEDLINE | ID: mdl-25519299

ABSTRACT

Three strains of an anaerobic, Gram-stain-positive coccobacillus were isolated from the intestines of mice. These strains shared 100 % similarity in their 16S rRNA gene sequences, but were distantly related to any described members of the family Lachnospiraceae (<94 %). The most closely related species with names that have standing in nomenclature were Robinsoniella peoriensis, Ruminococcus gnavus, Blautia producta and Clostridium xylanolyticum. Phylogenetic relationships based on 16S rRNA gene sequence analysis were confirmed by partial sequencing of hsp60 genes. The use of an in-house database search pipeline revealed that the new isolates are most prevalent in bovine gut samples when compared with human and mouse samples for Ruminococcus gnavus and B. producta. All three isolated strains shared similar cellular fatty acid patterns dominated by C16 : 0 methyl ester. Differences in the proportions of C12 : 0 methyl ester, C14 : 0 methyl ester and C18 : 1 cis-11 dimethyl acetal were observed when compared with phylogenetically neighbouring species. The major short-chain fatty acid produced by strain SRB-530-5-H(T) was acetic acid. This strain tested positive for utilization of d-fructose, d-galacturonic acid, d-malic acid, l-alanyl l-threonine and l-glutamic acid but was negative for utilization of amygdalin, arbutin, α-d-glucose, 3-methyl d-glucose and salicin, in contrast to the type strain of the closest related species Robinsoniella peoriensis. The isolates were not able to use mannitol for growth. Based on genotypic, phenotypic and chemotaxonomic characteristics, we propose to create the new genus and species Murimonas intestini gen. nov., sp. nov. to accommodate the three strains SRB-530-5-H(T) ( = DSM 26524(T) = CCUG 63391(T)) (the type strain of Murimonas intestini), SRB-509-4-S-H ( = DSM 27577 = CCUG 64595) and SRB-524-4-S-H ( = DSM 27578 = CCUG 64594).


Subject(s)
Bacteria, Anaerobic/classification , Gram-Positive Bacteria/classification , Intestines/microbiology , Phylogeny , Animals , Bacteria, Anaerobic/genetics , Bacteria, Anaerobic/isolation & purification , Bacterial Typing Techniques , Base Composition , Cattle , DNA, Bacterial/genetics , Fatty Acids/chemistry , Female , Gram-Positive Bacteria/genetics , Gram-Positive Bacteria/isolation & purification , Humans , Mice/microbiology , Mice, Inbred C57BL , Molecular Sequence Data , RNA, Ribosomal, 16S/genetics , Sequence Analysis, DNA
17.
Int J Pharm ; 457(1): 1-8, 2013 Nov 30.
Article in English | MEDLINE | ID: mdl-24055439

ABSTRACT

The objective of this study was to enhance the inter-tablet coating uniformity in an active coating process at lab and pilot scale by statistical design of experiments. The API candesartan cilexetil was applied onto gastrointestinal therapeutic systems containing the API nifedipine to obtain fixed dose combinations of these two drugs with different release profiles. At lab scale, the parameters pan load, pan speed, spray rate and number of spray nozzles were examined. At pilot scale, the parameters pan load, pan speed, spray rate, spray time, and spray pressure were investigated. A low spray rate and a high pan speed improved the coating uniformity at both scales. The number of spray nozzles was identified as the most influential variable at lab scale. With four spray nozzles, the highest CV value was equal to 6.4%, compared to 13.4% obtained with two spray nozzles. The lowest CV of 4.5% obtained with two spray nozzles was further reduced to 2.3% when using four spray nozzles. At pilot scale, CV values between 2.7% and 11.1% were achieved. Since the test of uniformity of dosage units accepts CV values of up to 6.25%, this active coating process is well suited to comply with the pharmacopoeial requirements.


Subject(s)
Drug Compounding/methods , Benzimidazoles/chemistry , Biphenyl Compounds , Drug Compounding/instrumentation , Nifedipine/chemistry , Tablets , Tetrazoles/chemistry
18.
AAPS PharmSciTech ; 14(1): 402-11, 2013 Mar.
Article in English | MEDLINE | ID: mdl-23354469

ABSTRACT

Coating of solid dosage forms is an important unit operation in the pharmaceutical industry. In recent years, numerical simulations of drug manufacturing processes have been gaining interest as process analytical technology tools. The discrete element method (DEM) in particular is suitable to model tablet-coating processes. For the development of accurate simulations, information on the material properties of the tablets is required. In this study, the mechanical parameters Young's modulus, coefficient of restitution (CoR), and coefficients of friction (CoF) of gastrointestinal therapeutic systems (GITS) and of active-coated GITS were measured experimentally. The dynamic angle of repose of these tablets in a drum coater was investigated to revise the CoF. The resulting values were used as input data in DEM simulations to compare simulation and experiment. A mean value of Young's modulus of 31.9 MPa was determined by the uniaxial compression test. The CoR was found to be 0.78. For both tablet-steel and tablet-tablet friction, active-coated GITS showed a higher CoF compared with GITS. According to the values of the dynamic angle of repose, the CoF was adjusted to obtain consistent tablet motion in the simulation and in the experiment. On the basis of this experimental characterization, mechanical parameters are integrated into DEM simulation programs to perform numerical analysis of coating processes.


Subject(s)
Chemistry, Pharmaceutical , Tablets , Dosage Forms , Gastrointestinal Tract/drug effects , Materials Testing
19.
Semin Thromb Hemost ; 36(1): 82-90, 2010 Feb.
Article in English | MEDLINE | ID: mdl-20391299

ABSTRACT

Von Willebrand factor cleaving protease was first identified in 1987 and was further classified several years later as ADAMTS-13 (a disintegrin and metalloproteinase with thrombospondin-1-like domains). Congenital and acquired deficiency of ADAMTS-13 is associated with thrombotic thrombocytopenic purpura (TTP) and other thrombotic microangiopathies (TMAs). Assays for measurement of ADAMTS-13 were developed in the late 1990s, and significant improvements have occurred in the testing protocols to allow them to be performed in routine hemostasis laboratories. This article reviews the original ADAMTS-13 activity assays and those currently available. It also reviews the consistency of results among various methods and discusses the clinical utility of ADAMTS-13 testing in TTP, TMA, and other disease conditions.


Subject(s)
ADAM Proteins/blood , Purpura, Thrombotic Thrombocytopenic/diagnosis , Thrombotic Microangiopathies/diagnosis , von Willebrand Factor/genetics , ADAM Proteins/metabolism , ADAMTS13 Protein , Collagen/metabolism , Enzyme-Linked Immunosorbent Assay/methods , Humans , Platelet Aggregation/drug effects , Protein Binding , Ristocetin/pharmacology , von Willebrand Factor/metabolism
20.
Blood Coagul Fibrinolysis ; 20(6): 475-83, 2009 Sep.
Article in English | MEDLINE | ID: mdl-19584715

ABSTRACT

We performed a retrospective audit of cross-laboratory testing of desmopressin and factor concentrate therapy to assess the potential utility of supplementary testing using the PFA-100 with functional von Willebrand factor (VWF) activity testing. Data were evaluated for a large number of patients with von Willebrand disease of type 1, type 2A or type 2M, as well as a comparative subset of individuals with haemophilia or carriers of haemophilia. Laboratory testing comprised pre and postdesmopressin, or pre and postconcentrate, evaluation of factor VIII, VWF antigen (VWF:Ag) and VWF ristocetin cofactor activity as traditionally performed, supplemented with collagen-binding (VWF:CB) testing and PFA-100 closure times. In brief, both therapies tended to normalize VWF test parameters and closure times in individuals with type 1 von Willebrand disease, with the level of correction in closure times related to the level of normalization of VWF, particularly the VWF:CB. However, although occasional correction of closure times was observed in patients with type 2A or type 2M von Willebrand disease, these did not in general normalize PFA-100 closure times either with desmopressin or factor concentrate therapy. In these patients, improvement in closure times was more likely in those in whom VWF:CB values normalized or when VWF:CB/VWF:Ag ratios normalized. This study confirms that there is a strong relationship between the presenting levels of plasma VWF and PFA-100 closure times, and that the supplementary combination of PFA-100 and VWF:CB testing might provide added clinical utility to current broadly applied testing strategies limited primarily to VWF:Ag, VWF ristocetin cofactor and factor VIII:coagulant. Future prospective investigations are warranted to validate these relationships and to investigate their therapeutic implications.


Subject(s)
Blood Coagulation Factors/therapeutic use , Deamino Arginine Vasopressin/therapeutic use , Drug Monitoring/methods , Platelet Function Tests/instrumentation , von Willebrand Diseases/blood , von Willebrand Factor/analysis , Drug Monitoring/instrumentation , Factor VIII/analysis , Hemophilia A/blood , Hemophilia A/drug therapy , Heterozygote , Humans , Retrospective Studies , Time Factors , von Willebrand Disease, Type 1/blood , von Willebrand Disease, Type 1/drug therapy , von Willebrand Disease, Type 2/blood , von Willebrand Disease, Type 2/drug therapy , von Willebrand Diseases/drug therapy