Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 4 de 4
Filter
Add more filters










Database
Language
Publication year range
1.
Opt Express ; 31(23): 38840-38853, 2023 Nov 06.
Article in English | MEDLINE | ID: mdl-38017978

ABSTRACT

Novel focusing optics composed of twin paraboloidal capillaries coated with Pt, for laboratory X-ray sources are presented and characterized. The optics are designed to focus the X-rays, resulting in an achromatic focused beam with photon energies up to 40 keV. The performance of the optics under different operational conditions is studied by comparing the energy-photon count spectra of the direct and focused beams. Based on these analyses, the optics gain and efficiency as a function of photon energy are determined. A focal spot of 8.5 µm with a divergence angle of 0.59° is observed. The obtained characteristics are discussed and related to theoretical considerations. Moreover, the suitability and advantages of the present optics for X-ray microdiffraction is demonstrated using polycrystalline aluminium. Finally, possibilities for further developments are suggested.

2.
J Appl Crystallogr ; 55(Pt 5): 1085-1096, 2022 Oct 01.
Article in English | MEDLINE | ID: mdl-36249500

ABSTRACT

X-ray Laue diffraction is an important method for characterizing the local crystallographic orientation and elastic strain in polycrystalline materials. Existing analysis methods are designed mainly to index a single or a few Laue diffraction pattern(s) recorded in a detector image. In this work, a novel method called dictionary-branch-bound (DBB) is presented to determine the crystallographic orientations of multiple crystals simultaneously illuminated by a parallel X-ray incident beam, using only the spot positions in a detector image. DBB is validated for simulated X-ray Laue diffraction data. In the simulation, up to 100 crystals with random crystallographic orientations are simultaneously illuminated. Fake spots are randomly added to the detector image to test the robustness of DBB. Additionally, spots are randomly removed to test the resilience of DBB against true spots that are undetected due to background noise and/or spot overlap. Poisson noise is also added to test the sensitivity of DBB to less accurate positions of detected spots. In all cases except the most challenging one, a perfect indexing with a mean angular error below 0.08° is obtained. To demonstrate the potential of DBB further, it is applied to synchrotron microdiffraction data. Finally, guidelines for using DBB in experimental data are provided.

3.
J Appl Crystallogr ; 54(Pt 1): 99-110, 2021 Feb 01.
Article in English | MEDLINE | ID: mdl-33833643

ABSTRACT

Laboratory diffraction contrast tomography (LabDCT) is a recently developed technique for 3D nondestructive grain mapping using a conical polychromatic beam from a laboratory-based X-ray source. The effects of experimental parameters, including accelerating voltage, exposure time and number of projections used for reconstruction, on the characterization of the 3D grain structure in an iron sample are quantified. The experiments were conducted using a commercial X-ray tomography system, ZEISS Xradia 520 Versa, equipped with a LabDCT module; and the data analysis was performed using the software package GrainMapper3D, which produces a 3D reconstruction from binarized 2D diffraction patterns. It is found that the exposure time directly affects the background noise level and thus the ability to distinguish weak spots of small grains from the background. With the assistance of forward simulations, it is found that spots from the first three strongest {hkl} families of a large grain can be seen with as few as 30-40 projections, which is sufficient for indexing the crystallographic orientation and resolving the grain shape with a reasonably high accuracy. It is also shown that the electron current is a more important factor than the accelerating voltage to be considered for optimizing the photon numbers with energies in the range of 20-60 keV. This energy range is the most important one for diffraction of common metals, e.g. iron and aluminium. Several suggestions for optimizing LabDCT experiments and 3D volume reconstruction are finally provided.

4.
Sci Rep ; 7: 42508, 2017 02 14.
Article in English | MEDLINE | ID: mdl-28195133

ABSTRACT

Remarkably little is known about the physical phenomena leading to nucleation of new perfect crystals within deformed metals during annealing, in particular how and where volumes with nearly perfect lattices evolve from structures filled with dislocations, and how local variations at the micrometer length scale affect this nucleation process. We present here the first experimental measurements that relate directly nucleation of recrystallization to the local deformation microstructure in the bulk of a sample of cold rolled aluminum, further deformed locally by a hardness indentation. White beam differential aperture X-ray microscopy is used for the measurements, allowing us to map a selected gauge volume in the bulk of the sample in the deformed state, then anneal the sample and map the exact same gauge volume in the annealed state. It is found that nuclei develop at sites of high stored energy and they have crystallographic orientations from those present in the deformed state. Accordingly we suggest that for each nucleus the embryonic volume arises from a structural element contained within the voxels identified with the same orientation. Possible nucleation mechanisms are discussed and the growth potentials of the nuclei are also analyzed and discussed.

SELECTION OF CITATIONS
SEARCH DETAIL
...