Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 2 de 2
Filter
Add more filters










Database
Language
Publication year range
1.
Eur J Neurol ; 21(6): 914-21, 2014 Jun.
Article in English | MEDLINE | ID: mdl-24661834

ABSTRACT

BACKGROUND AND PURPOSE: B-type natriuretric peptide (BNP) is a marker of cardiac dysfunction that is released from myocytes in response to ventricular wall stress. Previous studies suggested that BNP predicts stroke events in addition to classical risk factors. It was suggested that the BNP-associated risk results from coronary atherosclerosis or atrial fibrillation. METHODS: Three thousand six hundred and seventy five subjects from the population-based Heinz Nixdorf Recall study (45-75 years; 47.6% men) without previous stroke, coronary heart disease, myocardial infarcts, open cardiac valve surgery, pacemakers and defibrillators were followed up over 110.1 ± 23.1 months. Cox proportional hazards regressions were used to examine BNP as a stroke predictor in addition to vascular risk factors (age, gender, systolic blood pressure, low-density lipoprotein, high-density lipoprotein, diabetes, smoking), renal insufficiency, atrial fibrillation/known heart failure and coronary artery calcification. RESULTS: Eighty-nine incident strokes occurred (80 ischaemic, 9 hemorrhagic). Subjects suffering stroke had significantly higher BNP values at baseline than the remaining subjects [26.3 (Q1; Q3 = 12.9; 51.0) vs. 17.4 (9.4; 31.4); P < 0.001]. In a multivariable regression, log10 BNP was an independent stroke predictor [hazard ratio 1.96, 95% confidence interval (CI) 1.13-3.41; P = 0.017] in addition to age (1.24 per 5 years, CI 1.04-1.49; P = 0.016), systolic blood pressure (1.25 per 10 mmHg, CI 1.14-1.38; P < 0.001), smoking (2.05, CI 1.24-3.39; P = 0.005), atrial fibrillation/heart failure (2.25, CI 1.05-4.83; P = 0.037) and computed-tomography-based log10 (coronary artery calcification + 1) (1.47, CI 1.15-1.88; P = 0.002). Log10 BNP predicted stroke in men but not women, both in subjects ≤65 and >65 years. In subsequent analyses, BNP discriminated the incidence of cardioembolic stroke (P for trend = 0.001), but not stroke of macroangiopathic (P = 0.555), microangiopathic (P = 0.809) or unknown (P = 0.367) origin. CONCLUSIONS: BNP predicts presumable cardioembolic stroke independent of coronary calcification.


Subject(s)
Calcinosis/diagnosis , Coronary Artery Disease/diagnosis , Natriuretic Peptide, Brain/blood , Stroke/diagnosis , Age Factors , Aged , Biomarkers/blood , Calcinosis/blood , Coronary Artery Disease/blood , Female , Humans , Incidence , Male , Middle Aged , Predictive Value of Tests , Risk Factors , Sex Factors , Stroke/blood , Stroke/epidemiology
2.
Clin Res Cardiol ; 97(1): 43-8, 2008 Jan.
Article in English | MEDLINE | ID: mdl-17874036

ABSTRACT

BACKGROUND: Vascular closure devices (VCD) are well established to facilitate hemostasis after cardiac catheterization procedures. However, impairment of flow due to the reduction of femoral artery diameter remains a major concern. The present study aims to evaluate leg perfusion before and after application of collagen- and suture-based vascular closure devices. METHODS: A total of 366 patients (age: 64.3 years+/-10.7, male: 71.3%) were randomized to receive femoral access site closure with either a collagen-based closure device (group A) (n=214) or a suture-mediated device (group B) (n=152), immediately following coronary catheterization procedures. In all patients, the ankle-brachial-index (ABI) was measured before and the day after closure device application. RESULTS: In group A, mean ABI at baseline was 1.09+/-0.2, in group B 1.11+/-0.2. In both groups, there was a significant, albeit clinically not relevant, reduction in post-procedural ABI (group A: 1.04+/-0.2, p<0.01 vs baseline, group B: 1.06+/-0.2, p<0.01 vs baseline). DeltaABI was not different between both VCD groups (p=0.55). In patients with peripheral vascular disease (PVD), neither the Angioseal device (mean ABI at baseline 0.76+/-0.1) nor the Perclose-device (mean ABI at baseline 0.79+/-0.1) induced a remarkable impairment of leg perfusion (Angioseal: 0.77+/-0.1, p=0.9 vs baseline, Perclose: 0.78+/-0.1, p=1.0 vs baseline). Clinically, no aggravation of claudication was observed in the PVD patient group. CONCLUSION: Both vascular closure devices are not associated with clinically relevant reduction in ABI. There was no difference between the two groups with respect to the level of flow impairment. Both devices may be safely used in patients with reduced ABI.


Subject(s)
Cardiac Catheterization , Collagen , Postoperative Complications/etiology , Suture Techniques , Vascular Surgical Procedures/methods , Aged , Blood Flow Velocity , Female , Femoral Artery/surgery , Hemostasis , Humans , Intermittent Claudication/surgery , Leg/blood supply , Male , Middle Aged , Peripheral Vascular Diseases/surgery , Prospective Studies
SELECTION OF CITATIONS
SEARCH DETAIL
...