1.
Eur J Pharm Biopharm ; 50(2): 271-6, 2000 Sep.
Article in English | MEDLINE | ID: mdl-10962238

ABSTRACT

Factors affecting in-line near infrared (NIR) moisture measurement with a four-wavelength sensor were evaluated (choice of binder used in granulation liquid and the increase in particle size). An entire NIR spectrum is not necessary for the measurement of water, and often the use of only a few NIR wavelengths around the water band enables reliable and high-speed detection of moisture. Glass ballotini and microcrystalline cellulose (MCC) were used as model test materials. The binders studied were poly[1-(2-oxo-1-pyrrolidinyl)ethylene] (PVP) and gelatin. Full off-line NIR spectra of test materials at different levels of binder solutions were measured. The major spectral features for both the binders were bands around 1700 nm (first overtones CH related stretches) and 2200 nm (combination bands). Gelatin also had an NH band around 1500 nm (first overtones of NH stretches) and combination bands at about 2050 nm. Particle size effects were observed as an increase in spectra baseline. All these factors should be considered when choosing NIR wavelengths used for detection of water with a fixed wavelength set-up. A robust calibration model enables the development of in-process control of wet granulation processes.


Subject(s)
Technology, Pharmaceutical , Water/analysis , Calibration , Particle Size , Powders , Spectroscopy, Near-Infrared
2.
AAPS PharmSciTech ; 1(2): E10, 2000 May 06.
Article in English | MEDLINE | ID: mdl-14727843

ABSTRACT

A system for fluidized bed granulator automation with in-line multichannel near infrared (NIR) moisture measurement and a unique air flow rate measurement design was assembled, and the information gained was investigated. The multivariate process data collected was analyzed using principal component analysis (PCA). The test materials (theophylline and microcrystalline cellulose) were granulated and the calibration behavior of the multichannel NIR set-up was evaluated against full Fourier Transform (FT) NIR spectra. Accurate and reliable process air flow rate measurement proved critical in controlling the granulation process. The process data describing the state of the process was projected in two dimensions, and the information from various trend charts was outlined simultaneously. The absorbence of test material at correction wavelengths (NIR region) and the nature of material-water interactions affected the detected in-line NIR water signal. This resulted in different calibration models for the test materials. Development of process analytical methods together with new data visualization algorithms creates new tools for in-process control of the fluidized bed granulation.


Subject(s)
Technology, Pharmaceutical/instrumentation , Technology, Pharmaceutical/trends , Calibration , Drug Compounding/instrumentation , Drug Compounding/methods , Spectroscopy, Near-Infrared/methods , Technology, Pharmaceutical/methods , Water/chemistry