Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 2 de 2
Filter
Add more filters










Database
Language
Publication year range
1.
Bioresour Technol ; 361: 127664, 2022 Oct.
Article in English | MEDLINE | ID: mdl-35872271

ABSTRACT

Flexible biogas production can enable demand-oriented energy supply without the need for expensive gas storage expansions, but poses challenges to the stability of the anaerobic digestion (AD) process. In this work, biogas production of laboratory-scale AD of maize silage and sugar beets was optimized to cover the residual load of an electricity self-sufficient community using a simple process model based on first-order kinetics. Experiments show a good agreement between biogas demand, predicted, and measured biogas production. By optimizing biogas conversion schedules based on the measured gas production, a gas storage capacity of 7-8 h was identified for maximum flexibility, which corresponds to typical gas storage sizes at industrial biogas plants in Germany. Various stability indicators were continuously monitored and proved resilient process conditions. These results demonstrate that demand-oriented biogas production using model predictive control is a promising approach to enable existing biogas plants to provide balancing energy.


Subject(s)
Biofuels , Electricity , Anaerobiosis , Bioreactors , Kinetics , Methane , Silage , Zea mays
2.
Int Orthop ; 36(6): 1129-36, 2012 Jun.
Article in English | MEDLINE | ID: mdl-22113735

ABSTRACT

PURPOSE: Whilst excellent long-term results with contemporary uncemented stems have been reported for total hip arthroplasty in young patients, the survival rates for the whole reconstruction are often compromised by high failure rates on the acetabular site due to peri-acetabular osteolysis and accelerated wear. METHODS: In patients 60 years old or younger, we retrospectively reviewed the results at a minimum of ten years of 89 consecutive uncemented total hip replacements in 88 patients using the press-fit Fitmore acetabular component in combination with the CLS Spotorno stem and a 28-mm Metasul metal-on-metal articulation or a 28-mm alumina ceramic on conventional polyethylene bearing. The mean age at the time of surgery was 49 years (range, 25-60). The mean clinical and radiological follow-up was 12 years (range, 10-15). RESULTS: Six patients (six hips) died and two patients (two hips) were lost to follow-up. Five hips were revised: one for deep infection, one for peri-prosthetic femoral fracture, and one for aseptic stem loosening. In two hips an isolated revision of the acetabular liner was performed (one for recurrent dislocation and one for unexplained pain). No revision was performed for accelerated wear, osteolysis or aseptic loosening of the acetabular shell. We could not detect peri-acetabular osteolysis visible on plain radiographs in those hips evaluated radiographically. The Kaplan-Meier survival with revision for any reason as the endpoint was 94% (95% confidence interval, 86-97) at 12 years. CONCLUSIONS: The survival rates and the radiological outcomes with this implant combination in this young and active patient group are encouraging when compared to the results reported for other uncemented cups in this age group.


Subject(s)
Arthroplasty, Replacement, Hip/instrumentation , Arthroplasty, Replacement, Hip/methods , Cementation , Hip Prosthesis , Prosthesis Design , Adult , Aluminum Oxide , Arthroplasty, Replacement, Hip/adverse effects , Ceramics , Female , Humans , Kaplan-Meier Estimate , Male , Middle Aged , Outcome Assessment, Health Care , Postoperative Complications , Prosthesis Failure/etiology , Reoperation , Retrospective Studies
SELECTION OF CITATIONS
SEARCH DETAIL
...