1.
Sci Rep ; 14(1): 4468, 2024 02 23.
Article in English | MEDLINE | ID: mdl-38396023

ABSTRACT

Nuclear spin hyperpolarization increases the sensitivity of magnetic resonance dramatically, enabling many new applications, including real-time metabolic imaging. Parahydrogen-based signal amplification by reversible exchange (SABRE) was employed to hyperpolarize [1-13C]pyruvate and demonstrate 13C imaging in situ at 120 µT, about twice Earth's magnetic field, with two different signal amplification by reversible exchange variants: SABRE in shield enables alignment transfer to heteronuclei (SABRE-SHEATH), where hyperpolarization is transferred from parahydrogen to [1-13C]pyruvate at a magnetic field below 1 µT, and low-irradiation generates high tesla (LIGHT-SABRE), where hyperpolarization was prepared at 120 µT, avoiding magnetic field cycling. The 3-dimensional images of a phantom were obtained using a superconducting quantum interference device (SQUID) based magnetic field detector with submillimeter resolution. These 13C images demonstrate the feasibility of low-field 13C metabolic magnetic resonance imaging (MRI) of 50 mM [1-13C]pyruvate hyperpolarized by parahydrogen in reversible exchange imaged at about twice Earth's magnetic field. Using thermal 13C polarization available at 120 µT, the same experiment would have taken about 300 billion years.


Subject(s)
Magnetic Resonance Imaging , Pyruvic Acid , Magnetic Resonance Imaging/methods , Magnetic Resonance Spectroscopy/methods , Magnetic Fields
2.
Phys Med Biol ; 68(17)2023 08 17.
Article in English | MEDLINE | ID: mdl-37524086

ABSTRACT

Magnetorelaxometry imaging (MRXI) is a non-invasive, quantitative imaging technique for magnetic nanoparticles (MNPs). The image resolution of this technique significantly depends on the relaxation amplitude (ΔB). For this work, we measured the room temperature (299 K) relaxation signals of eight commercial MNP sample systems with different magnetic properties, in both fluid and immobilized states, in order to select the most suitable sample for a particular MRXI setting. Additionally, the effect of elevated temperatures (up to hyperthermia temperature, 335 K) on the relaxation signals of four different MNP systems (Synomag, Perimag, BNF and Nanomag) in both states were investigated. The ΔBvalues of fluid samples significantly decreased with increasing temperature, and the behaviour for immobilized samples depended on their blocking temperature (TB). For samples withTB< 299 K, ΔBalso decreased with increasing temperature. Whereas for samples withTB> 299 K, the opposite behaviour was observed. These results are beneficial for improving the image resolution in MRXI and show, among the investigated systems, and for our setup, Synomag is the best candidate for futurein vitroandin vivostudies. This is due to its consistently high ΔBbetween 299 and 335 K in both states. Our findings demonstrate the feasibility of temperature imaging by MRXI.


Subject(s)
Magnetite Nanoparticles , Temperature , Diagnostic Imaging , Magnetics , Physical Phenomena
3.
Nanoscale Adv ; 5(8): 2341-2351, 2023 Apr 11.
Article in English | MEDLINE | ID: mdl-37056624

ABSTRACT

Thermal noise magnetometry (TNM) is a recently developed magnetic characterization technique where thermally induced fluctuations in magnetization are measured to gain insight into nanomagnetic structures like magnetic nanoparticles (MNPs). Due to the stochastic nature of the method, its signal amplitude scales with the square of the volume of the individual fluctuators, which makes the method therefore extra attractive to study MNP clustering and aggregation processes. Until now, TNM signals have exclusively been detected by using a superconducting quantum interference device (SQUID) sensor. In contrast, we present here a tabletop setup using optically pumped magnetometers (OPMs) in a compact magnetic shield, as a flexible alternative. The agreement between results obtained with both measurement systems is shown for different commercially available MNP samples. We argue that the OPM setup with low complexity complements the SQUID setup with high sensitivity and bandwidth. Furthermore, the OPM tabletop setup is well suited to monitor aggregation processes because of its excellent sensitivity in lower frequencies. As a proof of concept, we show the changes in the noise spectrum for three different MNP immobilization and clustering processes. From our results, we conclude that the tabletop setup offers a flexible and widely adoptable measurement unit to monitor the immobilization, aggregation, and clustering of MNPs for different applications, including interactions of the particles with biological systems and the long-term stability of magnetic samples.

4.
Proc Natl Acad Sci U S A ; 118(11)2021 03 16.
Article in English | MEDLINE | ID: mdl-33707209

ABSTRACT

Neuronal spiking is commonly recorded by invasive sharp microelectrodes, whereas standard noninvasive macroapproaches (e.g., electroencephalography [EEG] and magnetoencephalography [MEG]) predominantly represent mass postsynaptic potentials. A notable exception are low-amplitude high-frequency (∼600 Hz) somatosensory EEG/MEG responses that can represent population spikes when averaged over hundreds of trials to raise the signal-to-noise ratio. Here, a recent leap in MEG technology-featuring a factor 10 reduction in white noise level compared with standard systems-is leveraged to establish an effective single-trial portrayal of evoked cortical population spike bursts in healthy human subjects. This time-resolved approach proved instrumental in revealing a significant trial-to-trial variability of burst amplitudes as well as time-correlated (∼10 s) fluctuations of burst response latencies. Thus, ultralow-noise MEG enables noninvasive single-trial analyses of human cortical population spikes concurrent with low-frequency mass postsynaptic activity and thereby could comprehensively characterize cortical processing, potentially also in diseases not amenable to invasive microelectrode recordings.


Subject(s)
Action Potentials , Magnetoencephalography/methods , Neocortex/physiology , Adult , Electroencephalography , Humans , Male , Middle Aged , Signal-To-Noise Ratio
5.
Sensors (Basel) ; 21(4)2021 Feb 09.
Article in English | MEDLINE | ID: mdl-33572285

ABSTRACT

Magnetic nanoparticles (MNP) offer a large variety of promising applications in medicine thanks to their exciting physical properties, e.g., magnetic hyperthermia and magnetic drug targeting. For these applications, it is crucial to quantify the amount of MNP in their specific binding state. This information can be obtained by means of magnetorelaxometry (MRX), where the relaxation of previously aligned magnetic moments of MNP is measured. Current MRX with optically pumped magnetometers (OPM) is limited by OPM recovery time after the shut-off of the external magnetic field for MNP alignment, therewith preventing the detection of fast relaxing MNP. We present a setup for OPM-MRX measurements using a commercially available pulsed free-precession OPM, where the use of a high power pulsed pump laser in the sensor enables a system recovery time in the microsecond range. Besides, magnetometer raw data processing techniques for Larmor frequency analysis are proposed and compared in this paper. Due to the high bandwidth (≥100 kHz) and high dynamic range of our OPM, a software gradiometer in a compact enclosure allows for unshielded MRX measurements in a laboratory environment. When operated in the MRX mode with non-optimal pumping performance, the OPM shows an unshielded gradiometric noise floor of about 600 fT/cm/Hz for a 2.3 cm baseline. The noise floor is flat up to 1 kHz and increases then linearly with the frequency. We demonstrate that quantitative unshielded MRX measurements of fast relaxing, water suspended MNP is possible with the novel OPM-MRX concept, confirmed by the accurately derived iron amount ratios of MNP samples. The detection limit of the current setup is about 1.37 µg of iron for a liquid BNF-MNP-sample (Bionized NanoFerrite) with a volume of 100 µL.


Subject(s)
Magnetite Nanoparticles , Magnetic Fields , Magnetics , Software
6.
J Magn Reson ; 237: 182-190, 2013 Dec.
Article in English | MEDLINE | ID: mdl-24252245

ABSTRACT

In ultra-low-field (ULF) NMR/MRI, a common scheme is to magnetize the sample by a polarizing field of up to hundreds of mT, after which the NMR signal, precessing in a field on the order of several µT, is detected with superconducting quantum interference devices (SQUIDs). In our ULF-NMR system, we polarize with up to 50mT and deploy a single-stage DC-SQUID current sensor with an integrated input coil which is connected to a wire-wound Nb gradiometer. We developed this system (white noise 0.50fT/√Hz) for assessing the feasibility of imaging neuronal currents by detecting their effect on the ULF-NMR signal. Magnetoencephalography investigations of evoked brain activity showed neuronal dipole moments below 50nAm. With our instrumentation, we have studied two different approaches for neuronal current imaging. In the so-called DC effect, long-lived neuronal activity shifts the Larmor frequency of the surrounding protons. An alternative strategy is to exploit fast neuronal activity as a tipping pulse. This so-called AC effect requires the proton Larmor frequency to match the frequency of the neuronal activity, which ranges from near-DC to ∼kHz. We emulated neuronal activity by means of a single dipolar source in a physical phantom, consisting of a hollow sphere filled with an aqueous solution of CuSO4 and NaCl. In these phantom studies, with physiologically relevant dipole depths, we determined resolution limits for our set-up for the AC and the DC effect of ∼10µAm and ∼50nAm, respectively. Hence, the DC effect appears to be detectable in vivo by current ULF-NMR technology.


Subject(s)
Magnetic Resonance Imaging/methods , Neurons/physiology , Phantoms, Imaging , Adult , Algorithms , Brain/physiology , Electric Stimulation , Electrodes , Electromagnetic Fields , Humans , Magnetoencephalography , Male , Models, Statistical , Signal-To-Noise Ratio
7.
Magn Reson Imaging ; 31(2): 171-7, 2013 Feb.
Article in English | MEDLINE | ID: mdl-22898690

ABSTRACT

Within the magnetic resonance imaging (MRI) community the trend is going to higher and higher magnetic fields, ranging from 1.5 T to 7 T, corresponding to Larmor frequencies of 63.8-298 MHz. Since for high-field MRI the magnetization increases with the applied magnetic field, the signal-to-noise-ratio increases as well, thus enabling higher image resolutions. On the other hand, MRI is possible also at ultra-low magnetic fields, as was shown by different groups. The goal of our development was to reach a Larmor frequency range of the low-field MRI system corresponding to the frequency range of human brain activities ranging from near zero-frequency (near-DC) to over 1 kHz. Here, first 2D MRI images of phantoms taken at Larmor frequencies of 100 Hz and 731 Hz will be shown and discussed. These frequencies are examples of brain activity triggered by electrostimulation of the median nerve. The method will allow the magnetic fields of the brain currents to influence the magnetic resonance image, and thus lead to a direct functional imaging modality of neuronal currents.


Subject(s)
Magnetic Resonance Imaging/methods , Algorithms , Brain/pathology , Computer Simulation , Equipment Design , Fourier Analysis , Humans , Image Processing, Computer-Assisted , Magnetic Fields , Neurons/pathology , Phantoms, Imaging , Photons , Signal-To-Noise Ratio , Time Factors
8.
Magn Reson Imaging ; 29(10): 1365-73, 2011 Dec.
Article in English | MEDLINE | ID: mdl-21907519

ABSTRACT

A number of different methods have been developed in order to detect the spreading of neuronal currents by means of noninvasive imaging techniques. However, all of these are subjected to limitations in the temporal or spatial resolution. A new approach of neuronal current detection is based on the use of low-field nuclear magnetic resonance (LF-NMR) that records brain activity directly. In the following, we describe a phantom study in order to assess the feasibility of neuronal current detection using LF-NMR. In addition to that, necessary preliminary subject studies examining somatosensory evoked neuronal currents are presented. During the phantom study, the influences of two different neuronal time signals on (1)H-NMR signals were observed. The measurements were carried out by using a head phantom with an integrated current dipole to simulate neuronal activity. Two LF-NMR methods based on a DC and an AC (resonant) mechanism were utilized to study the feasibility of detecting both types of magnetic brain signals. Measurements were made inside an extremely magnetically shielded room by using a superconducting quantum interference device magnetometer system. The measurement principles were validated applying currents of higher intensity than those typical of the neuronal currents. Through stepwise reduction of the amplitude of the current dipole strength, the resolution limits of the two measuring procedures were found. The results indicate that it is necessary to improve the signal-to-noise ratio of the measurement system by at least a factor of 38 in order to detect typical human neuronal activity directly by means of LF-NMR. In addition to that, ways of achieving this factor are discussed.


Subject(s)
Brain Mapping/methods , Brain/physiology , Evoked Potentials, Somatosensory/physiology , Magnetic Resonance Spectroscopy/methods , Brain Mapping/instrumentation , Humans , Phantoms, Imaging , Reproducibility of Results , Sensitivity and Specificity
9.
Biomed Tech (Berl) ; 56(2): 91-7, 2011 Apr.
Article in English | MEDLINE | ID: mdl-21446889

ABSTRACT

Magnetoencephalography measurements of somatosensory evoked brain activity taken inside an extremely magnetically shielded room are reported. The massive low frequency shielding in combination with a high sampling rate enabled the simultaneous observation of AC and near-DC effects. Neuronal activation was achieved by repetitive electrostimulation of the right median nerve above motor threshold using repetition rates from 3 Hz to 12 Hz. Stimulation sequences lasted for 10 s and were interspersed with periods of rest of equal length. The recorded magnetic fields, inferred for the N20m and a sustained near-DC component, revealed mainly dipolar patterns with mutually rotated orientations with angles of rotation of 30° and 75°. At the start of the stimulation we observed a fast rise within 100 ms in the evoked magnetic near-DC fields for which a maximum equivalent current dipole strength of 65 nAm was obtained. The sustained fields decayed by a factor of ∼4 to a lower DC-level B(γ) with a time constant τ of order of seconds. For 12 Hz repetition rate B(γ) was decreased. We suggest that the sustained neuronal activity evoked by repetitive electrostimulation could provide a suitable scheme to realize the direct detection of DC effects of neuronal currents via low field magnetic resonance.


Subject(s)
Algorithms , Brain/physiology , Diagnosis, Computer-Assisted/methods , Evoked Potentials, Somatosensory/physiology , Magnetoencephalography/methods , Adult , Female , Humans , Male , Reproducibility of Results , Sensitivity and Specificity