1.
Int Orthop ; 45(7): 1845-1852, 2021 07.
Article in English | MEDLINE | ID: mdl-33755774

ABSTRACT

PURPOSE: Radiographic parameters which correlate with poor clinical outcome after proximal humeral fractures could be helpful indicators to answer the question which patients should be followed up closer. Moreover, during surgery, radiographic parameters correlating with unfavourable outcome should be avoided. The primary aim of the study was to compare radiographic measurements between the injured and the contralateral, uninjured shoulder. The secondary aim was to correlate these radiographic parameters with post-operative shoulder function. METHODS: Fifty-eight patients (age: 55.6 ± 14.4 years, age at surgery) following angular stable plate fixation of a proximal humeral fracture (2-part fractures according to Neer: 24, 3-part: 25, 4-part: 9) were included in this retrospective cohort study. All patients were followed up at least six years (7.9 ± 1.4 after surgical intervention). During follow-up examination, the Constant score (CS) was assessed, and radiographs of both shoulders were taken. Radiographs were analyzed regarding lateral humeral offset, distance between tuberculum and head apex, head diameter, head height, perpendicular height, perpendicular center, vertical height, and angles between head and humeral shaft (CCD and HSA). These parameters were compared between the injured and uninjured shoulder. The cohort was divided in two groups: patients with a CS category of excellent/good and satisfying/worse. Both groups were tested regarding differences of demographic and radiographic parameters. RESULTS: The distance between tuberculum and head apex (2.6 ± 3.4 mm vs. 4.3 ± 2.1 mm; p = 0.0017), the CCD (123.1 ± 12.9° vs. 130.1 ± 7.3°; p = 0.0005), and the HSA (33.1 ± 12.8° vs. 40.1 ± 7.3°; p = 0.0066) were significantly smaller on the treated shoulder compared to the uninjured side. Patients reached a Constant score of 80.2 ± 17.4 (95% CI 75.6-84.8) points. Regarding outcome categories of the Constant score, 46 patients had a good to excellent outcome, and 12 patients had a satisfying or bad outcome. The comparison of these groups revealed that patients with inferior outcome in the long-term follow-up were older, female, had a more complex fracture type (AO classification), smaller lateral humeral offset, smaller head diameter and height, lower perpendicular height, and lower CCD and HSA angles. CONCLUSION: If the abovementioned parameters cannot be restored sufficiently during surgery, (reversed) shoulder arthroplasty might be a better solution to reach good post-operative outcome. Moreover, patients presenting these radiographic characteristics in the follow-up, older patients, and patients with a more complex fracture type should be followed up closer to possibly prevent poor shoulder function. TRIAL REGISTRATION: 83 250/2011BO2.


Subject(s)
Fracture Fixation, Internal , Shoulder Fractures , Adult , Aged , Bone Plates , Female , Follow-Up Studies , Humans , Middle Aged , Retrospective Studies , Shoulder Fractures/diagnostic imaging , Shoulder Fractures/surgery , Treatment Outcome
2.
Z Orthop Unfall ; 159(6): 638-648, 2021 Dec.
Article in English, German | MEDLINE | ID: mdl-32957148

ABSTRACT

BACKGROUND: Patient-reported outcome measures (PROMs) are gaining increasing importance in the context of quality management. Different PROMs and scoring tools are available to assess shoulder function after proximal humeral fracture (PHFx). In Europe, these include the Constant-Murley Score (CS), Neer Score (NS), Oxford Shoulder Score (OSS), University of California at Los Angeles Score (UCLA) and Disabilities of the Arm, Shoulder and Hands Score (DASH). In addition, the health-related quality of life can be assessed by the PROMs Short Form 36 (SF-36) and EuroQol (EQ-5D). Although all these test instruments assess shoulder function, the components to be answered objectively and subjectively vary and thus the possibility of independent assessment. The aim of the present study is to compare the correlation between the results of the different PROMs and the clinical screening tools in patients with PHFx. METHODS: 76 patients who were treated with angular stable plate osteosynthesis for a proximal humeral fracture between 01/2001 and 12/2005 were included in this trial. The outcome was measured with PROMs or clinical scoring tools such as CS, NS, OSS, UCLA, DASH, SF-36 and EQ-5D and a correlation coefficient between those evaluation tools was calculated. In addition, a distinction was made between the two force measurement methods (wrist [HG] vs. deltoid muscle [DM]) for CS. RESULTS: The correlation of the results of CS and NS (HG: r = 0.85; p < 0.001/DM: r = 0.93; p < 0.001), CS and UCLA (HG: r = 0.83; p < 0.001/DM: r = 0.86; p < 0.001), NS and UCLA (r = 0.91; p < 0.001) as well as DASH and OSS (r = 0.88; p < 0.001) was strongly expressed. A good comparability of the results was demonstrated between CS and OSS (HG: r = 0.63; p < 0.001/DM: r = 0.66; p < 0.001) and between CS and DASH (HG: r = 0.62; p < 0.001/DM: r = 0.61; p < 0.001). The correlation of CS (HG/DM) and UCLA with the EQ-5D index was also good. Assessment of the physical components of SF-36 with CS, NS, OSS, UCLA and DASH showed a moderate to good association, while the mental components of SF-36 showed a low correlation (p > 0.05). CONCLUSION: The assessment of shoulder function after proximal humerus fracture showed a very strong correlation within the clinical questionnaires (CS/NS/UCLA) and the PROMs (OSS/DASH). A strong correlation also exists between the clinical questionnaires and the PROMs. There was only a moderate correlation with the EQ-5D. The moderate to strong correlation between the physical components of SF-36, with almost no correlation between the mental components of SF-36, indicates that the quality of life restriction is based on a physical, but not on a mental impairment.


Subject(s)
Shoulder Fractures , Shoulder , Humans , Patient Reported Outcome Measures , Quality of Life , Treatment Outcome
3.
BMC Musculoskelet Disord ; 20(1): 403, 2019 Sep 04.
Article in English | MEDLINE | ID: mdl-31484528

ABSTRACT

BACKGROUND: The Constant score (CS) is one of the most frequently applied tools for the assessment of the shoulder joint. However, evaluation of strength is not standardized leading to potential bias when comparing different studies. METHODS: Seventy-six patients with fractures of the proximal humerus undergoing open reduction and internal fixation (ORIF) were assessed using standardized CS strength measurements at the deltoid muscle insertion and at the wrist in three different arm positions. Variation coefficients were evaluated for each patient and position. RESULTS: Forty women (57%) and 36 men (43%) were examined 96 months in mean after ORIF. We could state a maximum of 105.3 N difference if measurements were performed at the wrist or the insertion of the deltoid muscle in 90° forward flexion on the injured arm (167.9 ± 83.1 N; 62.6 ± 29.4 N). The lowest variation coefficient of the three performed measurements could be stated at the deltoid muscle insertion in a 90° abduction position in the scapula plane (6.94 ± 5.5). CONCLUSION: Following our study results, different positions of force measurement can change the total CS by a whole category (e.g. "very good" to "good"). We recommend performing the measurement at the insertion of the deltoid muscle in a 90° abduction position in the scapula plane. Otherwise, even in the non-injured, it is hard to reach a "normal" shoulder function, based on the CS. When using the CS as outcome parameter, authors must give detailed information about the force measuring and use an exact measuring device.


Subject(s)
Deltoid Muscle/physiology , Disability Evaluation , Range of Motion, Articular/physiology , Shoulder Fractures/surgery , Shoulder Joint/physiology , Adult , Aged , Aged, 80 and over , Bone Plates , CapZ Actin Capping Protein , Female , Follow-Up Studies , Fracture Fixation, Internal/methods , Humans , Male , Middle Aged , Muscle Strength/physiology , Open Fracture Reduction/instrumentation , Open Fracture Reduction/methods , Peptide Fragments , Reproducibility of Results , Shoulder Fractures/physiopathology
4.
J Shoulder Elbow Surg ; 24(5): 727-32, 2015 May.
Article in English | MEDLINE | ID: mdl-25441560

ABSTRACT

BACKGROUND: Very little information on medium- to long-term results is available for surgically treated proximal humeral fractures. The aim of this prospective treatment study was to present long-term results after angular stable plate fixation of displaced proximal humeral fractures and to detect which specific patient- and fracture-related parameters affect the clinical outcome. METHODS: We performed a prospective clinical and radiologic evaluation of 77 patients with a displaced proximal humeral fracture (28 Neer 2-part, 38 3-part, and 11 4-part fractures; 28 AO A fractures, 30 AO B fractures, and 19 AO C fractures) treated with angular stable plate fixation after a mean follow-up period of 96 months (range, 74-133 months). We assessed outcomes with the Constant, University of California-Los Angeles (UCLA), and Disabilities of the Arm, Shoulder, and Hand (DASH) scores and evaluated specific patient- and fracture-related parameters including complications. RESULTS: The mean Constant, University of California-Los Angeles (UCLA), and Disabilities of the Arm, Shoulder, and Hand (DASH) scores were 79, 31, and 12 points. Reasons for revisions were implant-related impingement (n = 13), screw perforation (n = 10), infection (n = 4), and secondary fracture displacement (n = 1). There was a significant association between worse score results and occurrence of secondary fracture displacement, screw perforation, residual bone deformities, and a rotator cuff defect at follow-up. CONCLUSIONS: Good medium- to long-term results after angular stable plate fixation of displaced proximal humeral fracture can be expected. A reconstruction within a range of 15° in both anteroposterior and axillary views and <5-mm tuberosity displacement should be the aim of head-preserving surgery to prevent complications, such as secondary fracture displacement and screw perforation, and a less favorable long-term result.


Subject(s)
Fracture Fixation, Internal/methods , Shoulder Fractures/surgery , Adult , Aged , Aged, 80 and over , Bone Plates/adverse effects , Bone Screws/adverse effects , Female , Fracture Fixation, Internal/adverse effects , Humans , Male , Middle Aged , Prospective Studies , Prosthesis-Related Infections/etiology , Prosthesis-Related Infections/surgery , Radiography , Recurrence , Reoperation , Rotator Cuff/diagnostic imaging , Rotator Cuff/surgery , Shoulder Fractures/diagnostic imaging , Shoulder Impingement Syndrome/etiology , Shoulder Impingement Syndrome/surgery , Time Factors , Treatment Outcome , Ultrasonography
SELECTION OF CITATIONS