Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 5 de 5
Filter
1.
Phys Imaging Radiat Oncol ; 29: 100523, 2024 Jan.
Article in English | MEDLINE | ID: mdl-38187170

ABSTRACT

Background and purpose: This work reports on the results of a survey performed on the use of computed tomography (CT) imaging for motion management, surface guidance devices, and their quality assurance (QA). Additionally, it details the collected user insights regarding professional needs in CT for radiotherapy. The purpose of the survey is to understand current practice, professional needs and future directions in the field of fan-beam CT in radiation therapy (RT). Materials and methods: An online institutional survey was conducted between 1-Sep-2022 and 10-Oct-2022 among medical physics experts at Belgian and Dutch radiotherapy institutions, to assess the current status, challenges, and future directions of motion management and surface image-guided radiotherapy. The survey consisted of a maximum of 143 questions, with the exact number depending on participants' responses. Results: The response rate was 66 % (31/47). Respiratory management was reported as standard practice in all but one institution; surface imaging during CT-simulation was reported in ten institutions. QA procedures are applied with varying frequencies and methodologies, primarily with commercial anatomy-like phantoms. Surface guidance users report employing commercial static and dynamic phantoms. Four main subjects are considered clinically important by the respondents: surface guidance, CT protocol optimisation, implementing gated imaging (4DCT, breath-hold), and a tattoo-less workflow. Conclusions: The survey highlights the scattered pattern of QA procedures for respiratory motion management, indicating the need for well-defined, unambiguous, and practicable guidelines. Surface guidance is considered one of the most important techniques that should be implemented in the clinical radiotherapy simulation workflow.

2.
Phys Imaging Radiat Oncol ; 29: 100522, 2024 Jan.
Article in English | MEDLINE | ID: mdl-38152701

ABSTRACT

Background and purpose: To obtain an understanding of current practice, professional needs and future directions in the field of fan-beam CT in RT, a survey was conducted. This work presents the collected information regarding the use of CT imaging for dose calculation and structure delineation. Materials and methods: An online institutional survey was distributed to medical physics experts employed at Belgian and Dutch radiotherapy institutions to assess the status, challenges, and future directions of QA practices for fan-beam CT. A maximum of 143 questions covered topics such as CT scanner availability, CT scanner specifications, QA protocols, treatment simulation workflow, and radiotherapy dose calculation. Answer forms were collected between 1-Sep-2022 and 10-Oct-2022. Results: A 66 % response rate was achieved, yielding data on a total of 58 CT scanners. For MV photon therapy, all single-energy CT scans are reconstructed in Hounsfield Units for delineation or dose calculation, and a direct- or stoichiometric method was used to convert CT numbers for dose calculation. Limited use of dual-energy CT is reported for photon (N = 3) and proton dose calculations (N = 1). For brachytherapy, most institutions adopt water-based dose calculation, while approximately 26 % of the institutions take tissue heterogeneity into account. Commissioning and regular QA include eleven tasks, which are performed by two or more professions (29/31) with varying frequencies. Conclusions: Dual usage of a planning CT limits protocol optimization for both tissue characterization and delineation. DECT has been implemented only gradually. A variation of QA testing frequencies and tests are reported.

3.
Adv Radiat Oncol ; 2(1): 53-61, 2017.
Article in English | MEDLINE | ID: mdl-28740915

ABSTRACT

PURPOSE: The aim of this study was to determine the effect of single fraction (SF) and multiple fraction (MF) radiation therapy (RT) on bone mineral density (BMD) in patients with cancer and bone metastases in the proximal femur. We studied this effect in the radiation field and within metastatic lesions, and differentiated between lytic, blastic, and mixed lesions. METHODS AND MATERIALS: This prospective cohort study comprised 42 patients with painful bone metastases, including 47 irradiated femora with 52 metastatic lesions in the proximal femur. Patients received either 8 Gy SF or 20 to 24 Gy in 5 to 6 fractions (MF). Quantitative computed tomography scans were obtained before RT and 4 and 10 weeks after the initial scan. Patients who received MF additionally underwent quantitative computed tomography on the final day of their treatment. Automated image registration was performed. Mean BMD was determined at each time point for each proximal femur (region of interest [ROI]-PF) and in greater detail for a region of interest that contained the metastatic lesion (ROI-ML). Statistical analysis was performed using linear mixed models. RESULTS: No significant differences in mean BMD were found between SF or MF RT over all time points in both ROI-PF and ROI-ML. Mean BMD did not change in ROI-PF with lytic and mixed lesions, but mean BMD in ROI-PF with blastic lesions increased to 109%. Comparably, when focused on ROI-ML, no differences in mean BMD were observed in lytic ROI-ML but mean BMD in mixed and blastic ROI-ML increased up to 105% and 121%, respectively. CONCLUSIONS: Ten weeks after palliative radiation therapy in patients with femoral metastatic lesions, a limited increase in BMD was seen with no beneficial effect of MF over SF RT. BMD in lytic lesions was unchanged but slightly increased in mixed and blastic lesions.

4.
Med Phys ; 30(11): 2981-7, 2003 Nov.
Article in English | MEDLINE | ID: mdl-14655945

ABSTRACT

In our institution, an individualized dosimetric quality assurance protocol for intensity modulated radiotherapy (IMRT) is being implemented. This protocol includes dosimetric measurements with a fluoroscopic electronic portal imaging device (EPID) for all IMRT fields while the patient is being irradiated. For some of the first patients enrolled in this protocol, significant beam attenuation by (carbon fiber) components of the treatment couch was observed. To study this beam attenuation in two-dimensional, EPID images were also acquired in absence of the patient, both with and without treatment couch and immobilization devices, as positioned during treatment. For treatments of head and neck cancer patients with a 6 MV photon beam, attenuation of up to 15% was detected. These findings led to the development of new tools and procedures for planning and treatment delivery to avoid underdosages in the tumor.


Subject(s)
Head and Neck Neoplasms/diagnostic imaging , Head and Neck Neoplasms/radiotherapy , Quality Assurance, Health Care/methods , Radiographic Image Enhancement/methods , Radiometry/methods , Radiotherapy Planning, Computer-Assisted/methods , Radiotherapy, Conformal/methods , Restraint, Physical/instrumentation , Artifacts , Fluoroscopy/methods , Humans , Immobilization , Lung Neoplasms/diagnostic imaging , Lung Neoplasms/radiotherapy , Photons , Quality Assurance, Health Care/standards , Radiographic Image Enhancement/standards , Radiometry/standards , Radiotherapy Dosage , Radiotherapy, Computer-Assisted/methods , Radiotherapy, Conformal/instrumentation , Radiotherapy, Conformal/standards , Reproducibility of Results , Restraint, Physical/methods , Restraint, Physical/standards , Scattering, Radiation , Sensitivity and Specificity
5.
Int J Radiat Oncol Biol Phys ; 54(2): 576-83, 2002 Oct 01.
Article in English | MEDLINE | ID: mdl-12243838

ABSTRACT

PURPOSE: To investigate the use of a fluoroscopic electronic portal imaging device (EPID) and radiopaque markers to detect internal cervix movement. METHODS AND MATERIALS: For 10 patients with radiopaque markers clamped to the cervix, electronic portal images were made during external beam irradiation. Bony structures and markers in the portal images were registered with the same structures in the corresponding digitally reconstructed radiographs of the planning computed tomogram. RESULTS: The visibility of the markers in the portal images was good, but their fixation should be improved. Generally, the correlation between bony structure displacements and marker movement was poor, the latter being substantially larger. The standard deviations describing the systematic and random bony anatomy displacements were 1.2 and 2.6 mm, 1.7 and 2.9 mm, and 1.6 and 2.7 mm in the lateral, cranial-caudal, and dorsal-ventral directions, respectively. For the marker movement those values were 3.4 and 3.4 mm, 4.3 and 5.2 mm, 3.2 and 5.2 mm, respectively. Estimated clinical target volume to planning target volume (CTV-PTV) planning margins (approximately 11 mm) based on the observed overall marker displacements (bony anatomy + internal cervix movement) are only marginally larger than the margins required to account for internal marker movement alone. CONCLUSIONS: With our current patient setup techniques and methods of setup verification and correction, the required CTV-PTV margins are almost fully determined by internal organ motion. Setup verification and correction using radiopaque markers might allow decreasing those margins, but technical improvements are needed.


Subject(s)
Cervix Uteri/diagnostic imaging , Fluoroscopy/instrumentation , Movement , Phantoms, Imaging , Uterine Cervical Neoplasms/radiotherapy , Female , Humans , Pelvic Bones/diagnostic imaging , Uterine Cervical Neoplasms/diagnostic imaging
SELECTION OF CITATIONS
SEARCH DETAIL
...