Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 4 de 4
Filter
Add more filters










Database
Language
Publication year range
1.
Article in English | MEDLINE | ID: mdl-38913531

ABSTRACT

Ultrasound elastography images which enable quantitative visualization of tissue stiffness can be reconstructed by solving an inverse problem. Classical model-based methods are usually formulated in terms of constrained optimization problems. To stabilize the elasticity reconstructions, regularization techniques such as Tikhonov method are used with the cost of promoting smoothness and blurriness in the reconstructed images. Thus, incorporating a suitable regularizer is essential for reducing the elasticity reconstruction artifacts while finding the most suitable one is challenging. In this work, we present a new statistical representation of the physical imaging model which incorporates effective signal-dependent colored noise modeling. Moreover, we develop a learning-based integrated statistical framework which combines a physical model with learning-based priors. We use a dataset of simulated phantoms with various elasticity distributions and geometric patterns to train a denoising regularizer as the learning-based prior. We use fixed-point approaches and variants of gradient descent for solving the integrated optimization task following learning-based plug-and-play (PnP) prior and regularization by denoising (RED) paradigms. Finally, we evaluate the performance of the proposed approaches in terms of relative mean square error (RMSE) with nearly 20% improvement for both piece-wise smooth simulated phantoms and experimental phantoms compared to the classical model-based methods and 12% improvement for both spatially-varying breast-mimicking simulated phantoms and an experimental breast phantom, demonstrating the potential clinical relevance of our work. Moreover, the qualitative comparisons of reconstructed images demonstrate the robust performance of the proposed methods even for complex elasticity structures that might be encountered in clinical settings.

2.
Phys Med Biol ; 69(11)2024 May 29.
Article in English | MEDLINE | ID: mdl-38670141

ABSTRACT

The relatively new tools of brain elastography have established a general trendline for healthy, aging adult humans, whereby the brain's viscoelastic properties 'soften' over many decades. Earlier studies of the aging brain have demonstrated a wide spectrum of changes in morphology and composition towards the later decades of lifespan. This leads to a major question of causal mechanisms: of the many changes documented in structure and composition of the aging brain, which ones drive the long term trendline for viscoelastic properties of grey matter and white matter? The issue is important for illuminating which factors brain elastography is sensitive to, defining its unique role for study of the brain and clinical diagnoses of neurological disease and injury. We address these issues by examining trendlines in aging from our elastography data, also utilizing data from an earlier landmark study of brain composition, and from a biophysics model that captures the multiscale biphasic (fluid/solid) structure of the brain. Taken together, these imply that long term changes in extracellular water in the glymphatic system of the brain along with a decline in the extracellular matrix have a profound effect on the measured viscoelastic properties. Specifically, the trendlines indicate that water tends to replace solid fraction as a function of age, then grey matter stiffness decreases inversely as water fraction squared, whereas white matter stiffness declines inversely as water fraction to the 2/3 power, a behavior consistent with the cylindrical shape of the axons. These unique behaviors point to elastography of the brain as an important macroscopic measure of underlying microscopic structural change, with direct implications for clinical studies of aging, disease, and injury.


Subject(s)
Aging , Brain , Elasticity Imaging Techniques , Humans , Aging/physiology , Brain/diagnostic imaging , Aged , Middle Aged , Adult , Elasticity , Male , Viscosity , Female , Aged, 80 and over , White Matter/diagnostic imaging , Young Adult
3.
Phys Med Biol ; 68(5)2023 02 27.
Article in English | MEDLINE | ID: mdl-36780698

ABSTRACT

Reverberant elastography provides fast and robust estimates of shear modulus; however, its reliance on multiple mechanical drivers hampers clinical utility. In this work, we hypothesize that for constrained organs such as the brain, reverberant elastography can produce accurate magnetic resonance elastograms with a single mechanical driver. To corroborate this hypothesis, we performed studies on healthy volunteers (n= 3); and a constrained calibrated brain phantom containing spherical inclusions with diameters ranging from 4-18 mm. In both studies (i.e. phantom and clinical), imaging was performed at frequencies of 50 and 70 Hz. We used the accuracy and contrast-to-noise ratio performance metrics to evaluate reverberant elastograms relative to those computed using the established subzone inversion method. Errors incurred in reverberant elastograms varied from 1.3% to 16.6% when imaging at 50 Hz and 3.1% and 16.8% when imaging at 70 Hz. In contrast, errors incurred in subzone elastograms ranged from 1.9% to 13% at 50 Hz and 3.6% to 14.9% at 70 Hz. The contrast-to-noise ratio of reverberant elastograms ranged from 63.1 to 73 dB compared to 65 to 66.2 dB for subzone elastograms. The average global brain shear modulus estimated from reverberant and subzone elastograms was 2.36 ± 0.07 kPa and 2.38 ± 0.11 kPa, respectively, when imaging at 50 Hz and 2.70 ± 0.20 kPa and 2.89 ± 0.60 kPa respectively, when imaging at 70 Hz. The results of this investigation demonstrate that reverberant elastography can produce accurate, high-quality elastograms of the brain with a single mechanical driver.


Subject(s)
Elasticity Imaging Techniques , Humans , Elasticity Imaging Techniques/methods , Magnetic Resonance Imaging , Phantoms, Imaging , Brain/diagnostic imaging , Magnetic Resonance Spectroscopy
4.
Front Oncol ; 11: 779071, 2021.
Article in English | MEDLINE | ID: mdl-34869029

ABSTRACT

We recently developed the photoacoustic dual-scan mammoscope (DSM), a system that images the patient in standing pose analog to X-ray mammography. The system simultaneously acquires three-dimensional photoacoustic and ultrasound (US) images of the mildly compressed breast. Here, we describe a second-generation DSM (DSM-2) system that offers a larger field of view, better system stability, higher ultrasound imaging quality, and the ability to quantify tissue mechanical properties. In the new system, we doubled the field of view through laterally shifted round-trip scanning. This new design allows coverage of the entire breast tissue. We also adapted precisely machined holders for the transducer-fiber bundle sets. The new holder increased the mechanical stability and facilitated image registration from the top and bottom scanners. The quality of the US image is improved by increasing the firing voltage and the number of firing angles. Finally, we incorporated quasi-static ultrasound elastography to allow comprehensive characterization of breast tissue. The performance of the new system was demonstrated through in vivo human imaging experiments. The experimental results confirmed the capability of the DSM-2 system as a powerful tool for breast imaging.

SELECTION OF CITATIONS