Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 7 de 7
Filter
Add more filters










Database
Language
Publication year range
1.
Phys Rev Lett ; 122(15): 157202, 2019 Apr 19.
Article in English | MEDLINE | ID: mdl-31050542

ABSTRACT

One of the key processes setting the speed of the ultrafast magnetization phenomena is the angular momentum transfer from and into the spin system. However, the way the angular momentum flows during ultrafast demagnetization and magnetization switching phenomena remains elusive so far. We report on time-resolved soft x-ray magnetic circular dichroism measurements of the ferrimagnetic GdFeCo alloy allowing us to record the dynamics of elemental spin and orbital moments at the Fe and Gd sites during femtosecond laser-induced demagnetization. We observe a complete transfer of spin and orbital angular momentum to the lattice during the first hundreds of femtoseconds of the demagnetization process.

2.
J Synchrotron Radiat ; 23(Pt 3): 700-11, 2016 05.
Article in English | MEDLINE | ID: mdl-27140149

ABSTRACT

The slicing facility FemtoSpeX at BESSY II offers unique opportunities to study photo-induced dynamics on femtosecond time scales by means of X-ray magnetic circular dichroism, resonant and non-resonant X-ray diffraction, and X-ray absorption spectroscopy experiments in the soft X-ray regime. Besides femtosecond X-ray pulses, slicing sources inherently also produce a so-called `halo' background with a different time structure, polarization and pointing. Here a detailed experimental characterization of the halo radiation is presented, and a method is demonstrated for its correct and unambiguous removal from femtosecond time-resolved data using a special laser triggering scheme as well as analytical models. Examples are given for time-resolved measurements with corresponding halo correction, and errors of the relevant physical quantities caused by either neglecting or by applying a simplified model to describe this background are estimated.

3.
Nat Commun ; 6: 8274, 2015 Sep 16.
Article in English | MEDLINE | ID: mdl-26374256

ABSTRACT

Nonlinear magnetization dynamics is essential for the operation of numerous spintronic devices ranging from magnetic memory to spin torque microwave generators. Examples are microwave-assisted switching of magnetic structures and the generation of spin currents at low bias fields by high-amplitude ferromagnetic resonance. Here we use X-ray magnetic circular dichroism to determine the number density of excited magnons in magnetically soft Ni80Fe20 thin films. Our data show that the common model of nonlinear ferromagnetic resonance is not adequate for the description of the nonlinear behaviour in the low magnetic field limit. Here we derive a model of parametric spin-wave excitation, which correctly predicts nonlinear threshold amplitudes and decay rates at high and at low magnetic bias fields. In fact, a series of critical spin-wave modes with fast oscillations of the amplitude and phase is found, generalizing the theory of parametric spin-wave excitation to large modulation amplitudes.

4.
J Synchrotron Radiat ; 22(5): 1301-5, 2015 Sep.
Article in English | MEDLINE | ID: mdl-26289284

ABSTRACT

A new but yet well proven way of making elliptically polarized dipole radiation from the BESSY II storage ring applicable to the SX700-type collimated plane-grating monochromator PM3 is described. It is shown that due to the limited vertical acceptance of the grating a simple use of vertical apertures is not possible in this case. Rather, deflecting the beam upwards or downwards by rotating the vertically collimating toroidal mirror M1 around the light axis leads to excellent performance. The resulting detuning of the photon energy can be taken into account by a readjustment of the monochromator internal plane mirror M2. The energy resolution of the beamline is not affected by the non-zero `roll' of the collimating mirror.

5.
J Synchrotron Radiat ; 21(Pt 5): 1090-104, 2014 Sep.
Article in English | MEDLINE | ID: mdl-25177998

ABSTRACT

Here the major upgrades of the femtoslicing facility at BESSY II (Khan et al., 2006) are reviewed, giving a tutorial on how elliptical-polarized ultrashort soft X-ray pulses from electron storage rings are generated at high repetition rates. Employing a 6 kHz femtosecond-laser system consisting of two amplifiers that are seeded by one Ti:Sa oscillator, the total average flux of photons of 100 fs duration (FWHM) has been increased by a factor of 120 to up to 10(6) photons s(-1) (0.1% bandwidth)(-1) on the sample in the range from 250 to 1400 eV. Thanks to a new beamline design, a factor of 20 enhanced flux and improvements of the stability together with the top-up mode of the accelerator have been achieved. The previously unavoidable problem of increased picosecond-background at higher repetition rates, caused by `halo' photons, has also been solved by hopping between different `camshaft' bunches in a dedicated fill pattern (`3+1 camshaft fill') of the storage ring. In addition to an increased X-ray performance at variable (linear and elliptical) polarization, the sample excitation in pump-probe experiments has been considerably extended using an optical parametric amplifier that supports the range from the near-UV to the far-IR regime. Dedicated endstations covering ultrafast magnetism experiments based on time-resolved X-ray circular dichroism have been either upgraded or, in the case of time-resolved resonant soft X-ray diffraction and reflection, newly constructed and adapted to femtoslicing requirements. Experiments at low temperatures down to 6 K and magnetic fields up to 0.5 T are supported. The FemtoSpeX facility is now operated as a 24 h user facility enabling a new class of experiments in ultrafast magnetism and in the field of transient phenomena and phase transitions in solids.

6.
J Synchrotron Radiat ; 20(Pt 4): 522-30, 2013 Jul.
Article in English | MEDLINE | ID: mdl-23765293

ABSTRACT

Aiming at advancing storage-ring-based ultrafast X-ray science, over the past few years many upgrades have been undertaken to continue improving beamline performance and photon flux at the Femtoslicing facility at BESSY II. In this article the particular design upgrade of one of the key optical components, the zone-plate monochromator (ZPM) beamline, is reported. The beamline is devoted to optical pump/soft X-ray probe applications with 100 fs (FWHM) X-ray pulses in the soft X-ray range at variable polarization. A novel approach consisting of an array of nine off-axis reflection zone plates is used for a gapless coverage of the spectral range between 410 and 1333 eV at a designed resolution of E/ΔE = 500 and a pulse elongation of only 30 fs. With the upgrade of the ZPM the following was achieved: a smaller focus, an improved spectral resolution and bandwidth as well as excellent long-term stability. The beamline will enable a new class of ultrafast applications with variable optical excitation wavelength and variable polarization.

7.
Phys Rev Lett ; 106(12): 127401, 2011 Mar 25.
Article in English | MEDLINE | ID: mdl-21517350

ABSTRACT

Femtosecond x-ray magnetic circular dichroism was used to study the time-dependent magnetic moment of 4f electrons in the ferromagnets Gd and Tb, which are known for their different spin-lattice coupling. We observe a two-step demagnetization with an ultrafast demagnetization time of 750 fs identical for both systems and slower times which differ sizeably with 40 ps for Gd and 8 ps for Tb. We conclude that spin-lattice coupling in the electronically excited state is enhanced up to 50 times compared to equilibrium.

SELECTION OF CITATIONS
SEARCH DETAIL
...