1.
Nuklearmedizin ; 50(2): 74-82, 2011.
Article in English | MEDLINE | ID: mdl-21286660

ABSTRACT

UNLABELLED: After the successful clinical introduction of PET/CT, a novel hybrid imaging technology combining PET with the versatile attributes of MRI is emerging. At the Forschungszentrum Jülich, one of four prototypes available worldwide combining a commercial 3T MRI with a newly developed BrainPET insert has been installed, allowing simultaneous data acquisition with PET and MRI. The BrainPET is equipped with LSO crystals of 2.5 mm width and Avalanche photodiodes (APD) as readout electronics. Here we report on some performance characteristics obtained by phantom studies and also on the initial BrainPET studies on various patients as compared with a conventional HR+ PET-only scanner. MATERIAL, METHODS: The radiotracers [18F]-fluoro-ethyl-tyrosine (FET), [11C]-flumazenil and [18F]-FP-CIT were applied. RESULTS: Comparing the PET data obtained with the BrainPET to those of the HR+ scanner demonstrated the high image quality and the superior resolution capability of the BrainPET. Furthermore, it is shown that various MR images of excellent quality could be acquired simultaneously with BrainPET scans without any relevant artefacts. DISCUSSION, CONCLUSION: Initial experiences with the hybrid MRI/BrainPET indicate a promising basis for further developments of this unique technique allowing simultaneous PET imaging combined with both anatomical and functional MRI.


Subject(s)
Brain Diseases/diagnosis , Brain/diagnostic imaging , Brain/pathology , Magnetic Resonance Imaging/instrumentation , Positron-Emission Tomography/instrumentation , Subtraction Technique/instrumentation , Equipment Design , Equipment Failure Analysis , Germany , Humans , Image Enhancement/instrumentation , Phantoms, Imaging , Reproducibility of Results , Sensitivity and Specificity
2.
J Magn Reson ; 181(2): 203-11, 2006 Aug.
Article in English | MEDLINE | ID: mdl-16716616

ABSTRACT

MRI is proving to be a very useful tool for sodium quantification in animal models of stroke, ischemia, and cancer. In this work, we present the practical design of a dual-frequency RF surface coil that provides (1)H and (23)Na images of the rat head at 4 T. The dual-frequency RF surface coil comprised of a large loop tuned to the (1)H frequency and a smaller co-planar loop tuned to the (23)Na frequency. The mutual coupling between the two loops was eliminated by the use of a trap circuit inserted in the smaller coil. This independent-loop design was versatile since it enabled a separate optimisation of the sensitivity and RF field distributions of the two coils. To allow for an easy extension of this simple double-tuned coil design to other frequencies (nuclei) and dimensions, we describe in detail the practical aspects of the workbench design and MRI testing using a phantom that mimics in vivo conditions. A comparison between our independent-loop, double-tuned coil and a single-tuned (23)Na coil of equal size obtained with a phantom matching in vivo conditions, showed a reduction of the (23)Na sensitivity (about 28 %) because of signal losses in the trap inductance. Typical congruent (1)H and (23)Na rat brain images showing good SNR ((23)Na: brain 7, ventricular cerebrospinal fluid 11) and spatial resolution ((23)Na: 1.25 x 1.25 x 5mm(3)) are also reported. The in vivo SNR values obtained with this coil were comparable to, if not better than, other contemporary designs in the literature.


Subject(s)
Brain/anatomy & histology , Magnetic Resonance Imaging/instrumentation , Animals , Brain Diseases/diagnosis , Equipment Design , Phantoms, Imaging , Radio Waves , Rats , Sodium Isotopes
3.
J Magn Reson ; 178(1): 121-8, 2006 Jan.
Article in English | MEDLINE | ID: mdl-16216539

ABSTRACT

A version of the chirp z-transform (CZT) enabling signal intensity and phase-preserving field-of-view scaling has been programmed. The algorithm is important for all single-point imaging sequences such as SPRITE when used with multiple data acquisition for T2* mapping or signal averaging. CZT has particular utility for SPRITE imaging of nuclei with short relaxation times such as sodium at high field. Here, a complete theory of the properties of CZT is given. This method operates entirely in k-space. It is compared with a conventional interpolation approach that works in image space after the application of a fast Fourier transformation.

4.
J Magn Reson ; 179(1): 64-72, 2006 Mar.
Article in English | MEDLINE | ID: mdl-16325438

ABSTRACT

Sodium density maps acquired with three SPRITE-based methods have been compared in terms of the resulting quantitative information as well as image quality and acquisition times. Consideration of factors relevant for the clinical implementation of SPRITE shows that the Conical-SPRITE variant is preferred because of a 20-fold reduction in acquisition time, slightly improved image quality, and no loss of quantitative information. The acquisition of a 3D data set (32x32x16; FOV=256x256x160 mm) for the quantitative determination of sodium density is demonstrated. In vivo Conical-SPRITE 23Na images of the brain of a healthy volunteer were acquired in 30 min with a resolution of 7.5x7.5x7.5 mm and a signal-to-noise ratio of 23 in cerebrospinal fluid and 17 in brain tissue.


Subject(s)
Brain Mapping/methods , Brain/metabolism , Magnetic Resonance Imaging/methods , Sodium/metabolism , Humans , Image Enhancement , Image Processing, Computer-Assisted , Imaging, Three-Dimensional , Sodium Isotopes
5.
J Magn Reson ; 169(1): 102-17, 2004 Jul.
Article in English | MEDLINE | ID: mdl-15183362

ABSTRACT

Two strategies for the optimization of centric scan SPRITE (single point ramped imaging with T1 enhancement) magnetic resonance imaging techniques are presented. Point spread functions (PSF) for the centric scan SPRITE methodologies are numerically simulated, and the blurring manifested in a centric scan SPRITE image through PSF convolution is characterized. Optimal choices of imaging parameters and k-space sampling scheme are predicted to obtain maximum signal-to-noise ratio (SNR) while maintaining acceptable image resolution. The point spread function simulation predictions are verified experimentally. The acquisition of multiple FID points following each RF excitation is described and the use of the Chirp z-Transform algorithm for the scaling of field of view (FOV) of the reconstructed images is illustrated. Effective recombination of the rescaled images for SNR improvement and T*2 mapping is demonstrated.


Subject(s)
Algorithms , Image Enhancement/methods , Magnetic Resonance Imaging/methods , Signal Processing, Computer-Assisted , Magnetic Resonance Imaging/instrumentation , Phantoms, Imaging , Reproducibility of Results , Sensitivity and Specificity , Stochastic Processes