Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 8 de 8
Filter
1.
World J Gastrointest Surg ; 16(4): 999-1007, 2024 Apr 27.
Article in English | MEDLINE | ID: mdl-38690060

ABSTRACT

In this editorial review, we comment on the article published in the recent issue of the World Journal of Gastrointestinal Surgery. Carcinoembryonic antigen (CEA) is a fetal glycoprotein and can be secreted in very small amounts from healthy adults after birth. CEA is widely used not only for diagnostic tumor markers but also importantly for the management of some gastrointestinal tumors. The most common clinical use is surveillance for the monitoring of colorectal carcinoma. However, CEA can become elevated in several malign or benign characterized pathologies. Serum CEA level may vary depending on the location of the lesion, whether it metastasizes or not, and its histopathological characteristics. It has been determined that cases with high preoperative CEA have a more aggressive course and the risk of metastasis to the lymph tissue and liver increases. In this editorial review, we focused on evaluating the role of CEA in clinical practice with a holistic approach, including the diagnostic and prognostic significance of CEA in patients with focal liver lesions, the role of CEA in follow-up after definitive surgery, and also hepatic resection for metastasis, and the management of all patients with raised CEA.

3.
Exp Clin Transplant ; 21(8): 657-663, 2023 08.
Article in English | MEDLINE | ID: mdl-37698400

ABSTRACT

OBJECYIVES: Ureteral complications are one of the most common complications after kidney transplant. Although these complications have been treated surgically in the past, almost all can be successfully treated with interventional methods today. In this study, we assessed the interventional treatment of ureteral complications after kidney transplants performed in our center and the long-term results of these treatments. MATERIALS AND METHODS: We performed a retrospective analysis of 2223 kidney transplant recipients seen between January 1, 2000, and May 1, 2020. Among these, 70 kidney transplant recipients who experienced ureteral leakage or ureteral obstruction in the early or late posttransplant period were included in the study. Complications within the first 2 months posttransplant were classified as early complications, whereas those occurring after 2 months were considered late complications. We treated all patients with interventional methods. RESULTS: In review of patients, 44 patients were diagnosed with ureteral obstruction (22 patients were early obstruction, 22 were late obstruction) and 26 patients with ureteral anastomosis leakage. All patients with early and late ureteral obstruction were successfully treated with percutaneous methods. In the group of patients with ureteral leakage, all patients except 2 patients were treated with interventional methods. For 2 patients with ureteral leakage, surgical treatment was necessary because of persistent leakage despite percutaneous treatment methods. CONCLUSIONS: Ureteral complications after kidney transplant can be successfully treated with interventional methods in experienced centers without the need for surgery.


Subject(s)
Kidney Transplantation , Ureter , Ureteral Obstruction , Humans , Ureteral Obstruction/diagnostic imaging , Ureteral Obstruction/etiology , Ureteral Obstruction/surgery , Kidney Transplantation/adverse effects , Retrospective Studies , Ureter/surgery , Transplant Recipients
4.
Diagn Interv Radiol ; 2023 Aug 31.
Article in English | MEDLINE | ID: mdl-37650522

ABSTRACT

PURPOSE: The purpose of this study is to establish local diagnostic reference levels (LDRLs) for computed tomography (CT) procedures using cloud-based automated dose-tracking software. METHODS: The study includes the dose data obtained from a total of 104,272 examinations performed on adult patients (>18 years) using 8 CT scanners over 12 months. The protocols included in our study were as follows: head CT without contrast, cervical spine CT without contrast, neck CT with contrast, chest CT without contrast, abdomen-pelvis CT without contrast, lumbar spine CT without contrast, high-resolution computed tomography (HRCT) of the chest, and coronary CT angiography (CTA). Dose data were collected using cloud-based automatic dose-tracking software. The 75th percentiles of the distributions of the median volume CT dose index (CTDIvol) and dose length product (DLP) values were used to determine the LDRLs for each protocol. The LDRLs were compared with national DRLs (NDRLs) and DRLs set in other countries. Inter-CT scanner variability, which is a measure of how well clinical practices are standardized, was determined for each protocol. Median values for each protocol were compared with the LDRLs for dose optimization in each CT scanner. RESULTS: The LDRLs (for DLP and CTDIvol, respectively) were 839 mGy.cm and 41.2 mGy for head CT without contrast, 530.6 mGy.cm and 19.8 mGy for cervical spine CT without contrast, 431.9 mGy.cm and 15.5 mGy for neck CT with contrast, 364.8 mGy.cm and 9.3 mGy for chest CT without contrast, 588.9 mGy. cm and 11.2 mGy for abdomen-pelvis CT without contrast, 713 mGy.cm and 24.3 mGy for lumbar spine CT without contrast, 326 mGy.cm and 9.5 mGy for HRCT, and 642.3 mGy.cm and 33.4 mGy for coronary CTA. The LDRLs were comparable to or lower than NDRLs and DRLs set in other countries for most protocols. The comparisons revealed the need for immediate initiation of an optimization process for CT protocols with higher dose distributions. Furthermore, protocols with high inter-CT scanner variability revealed the need for standardization. CONCLUSION: There is a need to update the NDRLs for CT protocols in Turkey. Until new NDRLs are established, local institutions in Turkey can initiate the optimization process by comparing their dose distributions to the LDRLs established in our study. Automated dose-tracking software can play an important role in establishing DRLs by facilitating the collection and analysis of large datasets.

5.
Turk Gogus Kalp Damar Cerrahisi Derg ; 30(4): 549-556, 2022 Oct.
Article in English | MEDLINE | ID: mdl-36605326

ABSTRACT

Background: This study aims to compare quantitative and qualitative image quality between standard computed tomography pulmonary angiography and dual-energy computed tomography pulmonary angiography protocols. Methods: Between September 2017 and August 2018, a total of 91 consecutive patients (34 males, 57 females; mean age: 65.9±15 years; range, 37 to 91 years) who were referred for computed tomography pulmonary angiography were randomly imaged with either a standard or dual-energy protocol. Standard protocol (n=49) was acquired with a 64-slice multidetector computed tomography scanner using 60 mL contrast media (18 g iodine). A third-generation dual-energy computed tomography scanner was utilized to acquire dual-energy computed tomography pulmonary angiography and simultaneous lung perfusion imaging (n=42), which required 40 mL contrast media (12 g iodine). Two radiologists reviewed images separately to determine interobserver variability. Attenuation and noise in three central and two segmental pulmonary arteries were measured; signal-to-noise ratio and contrast-to-noise ratio were calculated. A five-point scale was utilized to evaluate image quality and image noise qualitatively. Results: The standard protocol required a significantly higher amount of iodine. Comparison of two groups employing quantitative measurements (attenuation value in five pulmonary arteries, mean attenuation value, mean background noise, signal-to-noise ratio, and contrast-to-noise ratio) and employing qualitative measurements (five-point scale scores of image quality and image noise) revealed no significant difference between dual-energy and standard groups (p>0.05). Qualitative and quantitative evaluations demonstrated low interobserver variability. Conclusion: Dual-energy computed tomography pulmonary angiography protocol delivers image quality equal to standard protocol, while requiring less amount of iodinated contrast medium and providing simultaneous lung perfusion imaging to contribute the diagnosis of pulmonary embolism.

6.
J Comput Assist Tomogr ; 45(1): 151-156, 2021.
Article in English | MEDLINE | ID: mdl-33186173

ABSTRACT

OBJECTIVE: The aim of this study was to investigate the quantitative differences of dual-energy computed tomography perfusion imaging measurements in subsegmental pulmonary embolism (SSPE), between normal lung parenchyma (NLP) and hypoperfused segments (HPS) with and without thrombus on computed tomography angiography (CTA). METHODS: Lung attenuation, iodine density, and normalized uptake values were measured from HPS and NLP on iodine maps of 43 patients with SSPE. Presence of pulmonary embolism (PE) on CTA was recorded. One-way repeated-measures analysis of variance and Kruskal-Wallis analyses with post hoc comparisons were conducted. RESULTS: The numbers of HPS with and without SSPE on CTA were 45 (55.6%) and 36 (44.4%), respectively. Lung attenuation of NLP was significantly different from HPS (P < 0.001). Iodine density and normalized uptake values of HPS with PE were significantly lower than those of HPS without PE, which is significantly lower than NLP (P < 0.001). CONCLUSIONS: Subsegmental pulmonary embolism causes HPS on dual-energy computed tomography perfusion imaging, which demonstrates different iodine density and normalized uptake values depending on the presence of thrombus.


Subject(s)
Perfusion Imaging/methods , Pulmonary Embolism/diagnostic imaging , Adult , Aged , Aged, 80 and over , Computed Tomography Angiography , Female , Humans , Male , Middle Aged , Radiographic Image Interpretation, Computer-Assisted , Retrospective Studies , Sensitivity and Specificity , Young Adult
7.
Exp Clin Transplant ; 18(6): 744-748, 2020 11.
Article in English | MEDLINE | ID: mdl-33187466

ABSTRACT

Primary oxalosis is a rare hereditary disorder of metabolism resulting in accumulation of calcium oxalate in almost all tissues of the body. All published data point out the improvement of cardiac function after transplant. Here, we report the first case in the literature of an 8-year-old patient with primary oxalosis in which oxalosis implantations increased in cardiac tissue after liver transplant and manifested as new-onset ventricular tachycardia and cardiomyopathy, leading to death.


Subject(s)
Calcium Oxalate/metabolism , Cardiomyopathies/etiology , Hyperoxaluria, Primary/surgery , Liver Transplantation/adverse effects , Myocardium/metabolism , Tachycardia, Ventricular/etiology , Cardiomyopathies/diagnosis , Cardiomyopathies/metabolism , Cardiomyopathies/therapy , Child , Crystallization , Fatal Outcome , Humans , Hyperoxaluria, Primary/complications , Hyperoxaluria, Primary/diagnosis , Hyperoxaluria, Primary/metabolism , Living Donors , Male , Myocardium/pathology , Tachycardia, Ventricular/diagnosis , Tachycardia, Ventricular/metabolism , Tachycardia, Ventricular/therapy , Treatment Outcome
8.
J Med Ultrasound ; 26(2): 107-108, 2018.
Article in English | MEDLINE | ID: mdl-30065530

ABSTRACT

We present a case of acute abdominal pain due to partial torsion of spleen located in its own normal anatomical position in a 20-year-old woman, diagnosed by ultrasound and confirmed on computed tomography and treated laparoscopically.

SELECTION OF CITATIONS
SEARCH DETAIL
...