Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 2 de 2
Filter
Add more filters










Database
Language
Publication year range
1.
Crit Care Res Pract ; 2021: 6621555, 2021.
Article in English | MEDLINE | ID: mdl-34659830

ABSTRACT

BACKGROUND: Sedation of intensive care patients is needed for patient safety, but deep sedation is associated with adverse outcomes. Frontal electromyogram-based Responsiveness Index (RI) aims to quantify the level of sedation and is scaled 0-100 (low index indicates deep sedation). We compared RI-based sedation to Richmond Agitation-Sedation Scale- (RASS-) based sedation. Our hypothesis was that RI-controlled sedation would be associated with increased total time alive without mechanical ventilation at 30 days without an increased number of adverse events. METHODS: 32 critically ill adult patients with mechanical ventilation and administration of sedation were randomized to either RI- or RASS-guided sedation. Patients received propofol and oxycodone, if possible. The following standardized sedation protocol was utilized in both groups to achieve the predetermined target sedation level: either RI 40-80 (RI group) or RASS -3 to 0 (RASS group). RI measurement was blinded in the RASS group, and the RI group was blinded to RASS assessments. State Entropy (SE) values were registered in both groups. RESULTS: RI and RASS groups did not differ in total time alive in 30 days without mechanical ventilation (p=0.72). The incidence of at least one sedation-related adverse event did not differ between the groups. Hypertension was more common in the RI group (p=0.01). RI group patients were in the target RI level 22% of the time and RASS group patients had 57% of scores within the target RASS level. The RI group spent significantly more time in their target sedation level than the RASS group spent in the corresponding RI level (p=0.03). No difference was observed between the groups (p=0.13) in the corresponding analysis for RASS. Propofol and oxycodone were administered at higher RI and SE values and lower RASS values in the RI group than in the RASS group. CONCLUSION: Further studies with a larger sample size are warranted to scrutinize the optimal RI level during different phases of critical illness.

2.
Crit Care ; 19: 333, 2015 Sep 11.
Article in English | MEDLINE | ID: mdl-26370687

ABSTRACT

INTRODUCTION: Deep sedation is associated with adverse patient outcomes. We recently described a novel sedation-monitoring technology, the Responsiveness Index (RI), which quantifies patient arousal using processed frontal facial EMG data. We explored the potential effectiveness and safety of continuous RI monitoring during early intensive care unit (ICU) care as a nurse decision-support tool. METHODS: In a parallel-group controlled single centre proof of concept trial, patients requiring mechanical ventilation and sedation were randomized via sequential sealed envelopes following ICU admission. Control group patients received hourly clinical sedation assessment and daily sedation holds; the RI monitor was connected but data were concealed from clinical staff. The intervention group received control group care, but RI monitoring was visible and nurses were asked to adjust sedation to maintain patients with an RI>20 whenever possible. Traffic-light colour coding (RI<20, Red; 20-40, Amber; >40, Green) simplified decision-making. The intervention lasted up to 48 hours. Sixteen nurses were interviewed to explore their views of the novel technology. RESULTS: We analysed 74 patients treated per protocol (36 intervention; 38 control). The proportion of patients with RI<20 was identical at the start of monitoring (54% both groups). Overall, the proportion of time with RI<20 trended to lower values for the intervention group (median 16% (1-3rd quartile 8-30%) versus 33% (10-54%); P = 0.08); sedation and analgesic use was similar. A post hoc analysis restricted to patients with RI<20 when monitoring started, found intervention patients spent less time with low RI value (16% (11-45%) versus 51% (33-72%); P = 0.02), cumulative propofol use trended to lower values (median 1090 mg versus 2390 mg; P = 0.14), and cumulative alfentanil use was lower (21.2 mg versus 32.3 mg; P = 0.01). RASS scores were similar for both groups. Sedation related adverse event rates were similar (7/36 versus 5/38). Similar proportions of patients had sedation holds (83% versus 87 %) and were extubated (47% versus 44%) during the intervention period. Nurses valued the objective visible data trends and simple colour prompts, and found RI monitoring a useful adjunct to existing practice. CONCLUSIONS: RI monitoring was safe and acceptable. Data suggested potential to modify sedation decision-making. Larger trials are justified to explore effects on patient-centred outcomes. TRIAL REGISTRATION: NCT01361230 (registered April 19, 2010).


Subject(s)
Conscious Sedation/methods , Consciousness Monitors , Monitoring, Physiologic/methods , Respiration, Artificial/methods , Adult , Aged , Aged, 80 and over , Female , Humans , Male , Middle Aged
SELECTION OF CITATIONS
SEARCH DETAIL
...