1.
Radiat Prot Dosimetry ; 163(3): 319-24, 2015 Feb.
Article in English | MEDLINE | ID: mdl-24891405

ABSTRACT

The purpose of this study is to present a national survey that was performed in Greece for the establishment of national Dose Reference Levels (DRLs) for seven common adult Computed Tomography (CT) examinations. Volumetric computed tomography dose index and dose-length product values were collected from the post-data page of 65 'modern' systems that incorporate tube current modulation. Moreover, phantom dose measurements on 26 'older' systems were performed. Finally, the effective dose to the patient from a typical acquisition during these examinations was estimated. The suggested national DRLs are generally comparable with respective published values from similar European studies, with the exception of sinuses CT, which presents significantly higher values. This fact, along with the large variation of the systems' dose values that were observed even for scanners of the same type, indicates a need for further patient protection optimisation without compromising the clinical outcome.


Subject(s)
Cone-Beam Computed Tomography/statistics & numerical data , Cone-Beam Computed Tomography/standards , Environmental Exposure/analysis , Environmental Exposure/standards , Whole-Body Counting/statistics & numerical data , Whole-Body Counting/standards , Adult , Body Burden , Cone-Beam Computed Tomography/instrumentation , Equipment Design , Equipment Failure Analysis/standards , Greece , Guidelines as Topic , Humans , Male , Phantoms, Imaging/standards , Radiation Dosage , Radiation Protection/standards , Radiation Protection/statistics & numerical data , Reference Values
2.
Radiat Prot Dosimetry ; 147(1-2): 202-5, 2011 Sep.
Article in English | MEDLINE | ID: mdl-21821614

ABSTRACT

The purpose of this study is to evaluate and compare the performance of 52 full field digital (FFD) and computed radiography (CR) mammography systems checked by the Greek Atomic Energy Commission with respect to dose and image quality. Entrance surface air kerma (ESAK) was measured and average glandular dose (AGD) was calculated according to the European protocol on dosimetry in mammography. The exposures were performed using the clinical protocol of each laboratory. The image quality was assessed by the total score of resolved phantom structures incorporated in an American College of Radiology accreditation phantom. The mean ESAK values for FFD and CR systems were 4.59 ± 1.93 and 5.0 ± 1.78 mGy, respectively, whereas the AGD yielded a mean value of 1.06 ± 0.36 mGy for the FFD and 1.04 ± 0.35 mGy for the CR systems. Considering image quality, FFD systems indicated a mean total score of 13.04 ± 0.89, whereas CR systems a mean total score of 11.54 ± 1.06.


Subject(s)
Breast/radiation effects , Mammography , Radiographic Image Enhancement , Tomography, X-Ray Computed , Breast/pathology , Female , Greece , Humans , Phantoms, Imaging , Radiation Dosage