Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 5 de 5
Filter
1.
Acta Orthop Belg ; 90(1): 51-56, 2024 Mar.
Article in English | MEDLINE | ID: mdl-38669649

ABSTRACT

Patient-specific instrumentation (PSI) was introduced to improve post-operative alignment, and consequently the revision rate and clinical results after total knee arthroplasty (TKA). Short- to mid-term data are conflicting regarding these theoretical advantages of PSI. The purpose of this retrospective analysis was to evaluate the survival rate and clinical outcome in PSI TKA 8.4 years after initial surgery. To our knowledge, no other study investigated long-term follow-up of TKA procedures using PSI. From a total cohort of 184 consecutive patients (200 TKA) 136 patients (144 TKA, 72%) were prospectively analysed at a mean follow-up of 8.4 years (±0.4). A survival analysis with all-cause revision of TKA as endpoint was performed. Patient-reported outcome measures (PROMs) were obtained preoperatively and after 1-, 2-, 5-, and 8.4-years of follow-up. Differences between these moments of follow-up were analysed. At final follow-up, 4 TKAs (2%) had undergone revision, all between 2-4 years after primary surgery. Reasons for revision were late infection, aseptic loosening, instability and polyethylene insert breakage. The median score of certain PROMs (WOMAC, VAS, EQ-index, EQ-VAS) decreased compared to previous follow-up scores but were significantly higher than preoperative scores. After 8.4 years of follow-up, no additional revision surgery was performed compared to 5-years postoperatively. Certain PROMs at 8.4-year follow-up decreased compared to earlier moments of follow-up, but all PROMs improved compared to preoperative PROMs.


Subject(s)
Arthroplasty, Replacement, Knee , Knee Prosthesis , Patient Reported Outcome Measures , Prosthesis Failure , Reoperation , Humans , Arthroplasty, Replacement, Knee/instrumentation , Arthroplasty, Replacement, Knee/methods , Male , Female , Aged , Reoperation/statistics & numerical data , Follow-Up Studies , Prospective Studies , Middle Aged , Retrospective Studies , Treatment Outcome , Aged, 80 and over
2.
Knee Surg Sports Traumatol Arthrosc ; 31(11): 5137-5144, 2023 Nov.
Article in English | MEDLINE | ID: mdl-37796308

ABSTRACT

PURPOSE: The aim of this prospective randomised controlled study was to compare wear characteristics and functional outcome between deep-dished mobile bearing (MB) and fixed bearing (FB) cemented total knee arthroplasty (TKA). We hypothesised that deep-dished MB reduces polyethylene wear and improves patient-reported outcome measures. METHODS: A total of 50 patients were randomised to receive a MB or FB tibia component of the same cemented TKA design. Patients were evaluated over a 5-year follow-up period. Medial and lateral wear were assessed using model-based Roentgen Stereophotogrammetric Analysis (RSA) and compared with the direct postoperative minimal joint space measurement. Functional outcome was assessed by the clinician-derived KSS and OKS, WOMAC, LEAS, and FJS-12. All data were derived using a general linear mixed model. RESULTS: At 5-year follow-up, decreased wear in the MB compared to the FB group was observed on the lateral side (0.07 ± 0.17 mm, p = 0.026), but not on the medial side (0.31 ± 0.055 mm, p = 0.665). Functional outcomes improved with a statistical significant effect over time, with no significant differences between groups (all p > 0.17). CONCLUSION: This model-based RSA study with 5-year follow-up showed that cemented deep-dished MB reduced lateral polyethylene wear as compared to FB in a single TKA system, whilst clinical outcomes were comparable. Longer follow-up is needed to establish clinical implications of these altered wear patterns and determine type of wear. LEVEL OF EVIDENCE: Level 1 randomised controlled trial.


Subject(s)
Arthroplasty, Replacement, Knee , Knee Prosthesis , Osteoarthritis, Knee , Humans , Knee Joint/surgery , Prospective Studies , Prosthesis Design , Polyethylene , Osteoarthritis, Knee/surgery
3.
J Clin Orthop Trauma ; 18: 144-149, 2021 Jul.
Article in English | MEDLINE | ID: mdl-33996459

ABSTRACT

PURPOSE: The aim of this study was to provide a short term comparison in radiological and clinical outcome between Bi-Cruciate Retaining (BCR)- and Cruciate Retaining (CR) Total Knee Arthroplasty (TKA). METHODS: The cohort consists of 122 patients undergoing a TKA with PSI, equally distributed over the BCR- and CR-TKA group. Perioperative conditions were observed and radiological images were analysed pre-, 6-weeks, and 1-year postoperative to quantify alignment differences between BCR- and CR-TKA. Preoperatively predicted templates were compared with the implanted size to determine predictive value. In addition mean range of motion and revision rates were determined in both groups. RESULTS: No significant difference was observed in amount of outliers in component alignment between BCR- and CR-TKA. Outliers of the Hip-Knee-Ankle-Axis (HKA-axis) occurred significantly more frequent (P = 0.009) in the BCR-group (37.7%) compared to CR-TKA (18.0%). No clinically relevant differences regarding the predictive sizing of implant components was obtained. No significant differences were observed in revision rates (P = 1.000) and ROM (p = 0.425) between the BCR-groep and CR-group at 2-years FU. CONCLUSION: This study illustrates that although the HKA-axis was not fully restored, bi-cruciate retaining surgical technique for BCR-TKA is safe and effective with comparable radiological and clinical outcome as CR TKA. Randomized controlled trials with longer follow up on the HKA-axis alignment and clinical parameters are needed to confirm the presented results and should focus on possible cut off values concerning leg axis in order to define in what patients a BCR-TKA can safely be used. LEVEL OF EVIDENCE IV: Retrospective Case Controlled Study.

4.
Knee ; 28: 51-56, 2021 Jan.
Article in English | MEDLINE | ID: mdl-33307319

ABSTRACT

BACKGROUND: The cruciate retaining lipped (CR-lipped) bearing is designed to provide more anterior-posterior (AP) stability and could be employed to resolve excessive intraoperative laxity during the cruciate retaining TKA (CR-TKA). The aim of the study was to determine whether the CR-lipped bearing in CR-TKAs with a perioperative excessive laxity allows equivalent functional results as compared to the standard CR articulation. METHODS: A cohort of 111 TKAs with CR-lipped bearings was matched to a cohort of conventional CR bearings regarding age and sex. The CR-lipped bearing was used in patients with excessive knee AP laxity and the regular CR bearing was used in patients without excessive AP laxity during TKA. Various PROMs (WOMAC, KSS, SF-36) were assessed preoperatively and at 5-years postoperative in combination with revision rate and Range of Motion (ROM). RESULTS: PROMs did not differ significantly between both groups 5-years postoperatively. Mean ROM (flexion) 5-years postoperatively was not significantly different. The implant survivorship was 100% for both cohorts with revision for any reason as end point. CONCLUSION: Based on these results, the CR-lipped bearing is a safe and effective solution for mild interoperatively assessed PCL laxity during CR-TKA without loss of function or decreased survivorship at 5 years. Peroperative conversion to a PS-TKA in order to obtain satisfactory functional scores might therefore not be necessary when mild PCL laxity is observed during surgery. Further research should focus on verifying this approach and longer follow-up is needed to generate data on long term survivorship. LEVEL OF EVIDENCE: Level IV therapeutic, retrospective, cohort study.


Subject(s)
Arthroplasty, Replacement, Knee/methods , Joint Instability/surgery , Knee Prosthesis , Osteoarthritis, Knee/surgery , Aged , Aged, 80 and over , Female , Humans , Knee Joint/surgery , Male , Middle Aged , Posterior Cruciate Ligament/surgery , Prosthesis Design , Range of Motion, Articular , Retrospective Studies
5.
Eur J Orthop Surg Traumatol ; 30(4): 723-729, 2020 May.
Article in English | MEDLINE | ID: mdl-31950265

ABSTRACT

BACKGROUND: Achieving an optimal limb alignment is an important factor affecting the long-term survival of total knee arthroplasty (TKA). This is the first study to look at the limb alignment and orientation of components in TKA using a novel image-free handheld robotic sculpting system. METHODS: This case-controlled study retrospectively compared limb and component alignment of 77 TKAs performed with a robot (Robot-group) with a matched control group of patients who received conventional alignment with intramedular rods (Control group). Alignment and component positioning was measured on full-leg weight-bearing and standard lateral X-rays by two independent observers. The image-free handheld robotic sculpting system calculated the planned and achieved mechanical axis (MA). Outliers were defined as > 3° deviation from planned alignment. RESULTS: Mean MA was 180.1° (SD = 1.9) in the Robot-group, compared to the Control group with a mean MA of 179.1° (SD = 3.1, p = 0.028). We observed 5 outliers (6%) in the Robot-group and 14 outliers (18%, p = 0.051) in the Control group. Fraction of outliers of the frontal tibial component was 0% in the Robot-group versus 8% in the Control group (p = 0.038). There were no other statistical differences regarding the implant positioning between both groups. CONCLUSION: The Robot-group showed significantly less outliers compared to the conventional technique. Whether these differences are clinically relevant is questionable and should be investigated on the long term. Randomized controlled trials with larger patient series will be needed in the future to confirm our preliminary results.


Subject(s)
Arthroplasty, Replacement, Knee , Bone Malalignment , Postoperative Complications/prevention & control , Robotics/methods , Surgery, Computer-Assisted , Arthroplasty, Replacement, Knee/adverse effects , Arthroplasty, Replacement, Knee/instrumentation , Arthroplasty, Replacement, Knee/methods , Bone Malalignment/etiology , Bone Malalignment/prevention & control , Case-Control Studies , Female , Humans , Image Interpretation, Computer-Assisted/methods , Knee Joint/diagnostic imaging , Knee Joint/surgery , Male , Middle Aged , Outcome and Process Assessment, Health Care , Radiography/methods , Surgery, Computer-Assisted/instrumentation , Surgery, Computer-Assisted/methods
SELECTION OF CITATIONS
SEARCH DETAIL
...