1.
Indian Pacing Electrophysiol J ; 22(3): 131-136, 2022.
Article in English | MEDLINE | ID: mdl-35121144

ABSTRACT

INTRODUCTION: This study evaluates the accuracy of iECGs in comparison to the gold standard ECG in adult patients with congenital heart disease and recommends the appropriate iECG derivation based on the patient's characteristics. METHODS: In 106 adults (51 female, 55 male) with congenital heart disease, a gold standard 12-lead ECG was recorded, followed by three iECGs with the Apple Watch series 4, which correspond to Einthoven leads I, II, and III. Two experienced and independent cardiologists analyzed the time intervals, amplitudes, and polarities of the ECG parameters as well as the rhythm type and correlated the patient characteristics with the iECG parameters. RESULTS: The iECG parameters of all three iECG leads correlate strongly with those of the gold standard ECG, with exception of the P and T wave durations. We demonstrated that the informative value of the individual iECGs was independent of the patient's characteristics, in particular the heart axis, anatomy, and situs, even if the quality of the Einthoven III-like derivation was partially inadequate. The automatic rhythm analysis of the Apple Watch and the heart rhythm classification of a standard ECG analyzed manually by a cardiologist corresponded in 77%. CONCLUSION: iECG recordings of adults with congenital heart disease provide comparable results with Einthoven recordings I, II, and III of the 12-lead ECG and current data encourage the use of the Apple Watch not only in patients with structurally normal hearts but also in patients with congenital heart disease.

2.
Cardiol Young ; 32(10): 1633-1637, 2022 Oct.
Article in English | MEDLINE | ID: mdl-34865668

ABSTRACT

INTRODUCTION: Telemedicine gained an increasing use throughout the last years. Lifestyle tools like the Apple watch seem to have an increasing spread even in remote areas and underdeveloped regions. The increasing availability of these tools offers the chance to use the health care functions of these devices to improve provision of professional medical care. First data on the use of the Apple Watch as a remote monitoring device in children have been reported, showing good acceptability and usability of the Apple Watch for symptom monitoring in children. This study aimed to evaluate the accuracy of the Apple Watch iECG in comparison to a standard 12-lead ECG in pre-term babies. METHODS: In this prospective, single-arm study, consecutive preterm neonates hospitalised in Leipzig University Hospital neonatal ICU were eligible. A 12-lead ECG and an iECG using Apple Watch 4 were performed. iECG and 12-lead ECG measurements were performed by a paediatric cardiologist. Cardiac rhythm was classified and amplitudes and timing intervals were analysed for comparability. RESULTS: Fifty preterm neonates, gestational week (23-36 weeks), and body weight (0.65-3.09 kg) were enrolled. Overall good quality and excellent correlation of the Apple Watch generated iECG in comparison to the standard 12-lead ECG could be demonstrated (p < 0.001). When interpreted by a paediatric cardiologist, a correct rhythm classification could be done in 100% of cases. CONCLUSION: The Apple Watch iECG seems to be a valuable tool to record an ECG comparable to lead I of the standard 12-lead ECG even in pre-term neonates. With a widespread availability and excellent connectivity, the Apple Watch iECG function may provide practitioners with a tool to send an iECG for interpretation to a paediatric cardiac specialist.


Subject(s)
Electrocardiography , Telemedicine , Humans , Child , Infant, Newborn , Prospective Studies , Data Collection
3.
Cardiol Young ; 32(10): 1598-1602, 2022 Oct.
Article in English | MEDLINE | ID: mdl-34889179

ABSTRACT

INTRODUCTION: Cardiopulmonary exercise testing represents the diagnostic tool for determining cardiopulmonary function. Especially in small children, exercise testing is extremely challenging. To address this problem, field testing has been implemented using small mobile devices. This study aims at using this protocol for developing normal values for cardiopulmonary exercise testing in very young children. MATERIAL AND METHODS: Healthy children aged 4-8 years were recruited. All children were tested according to an outdoor protocol, in which they were instructed to walk, then run slowly, then a little harder and at last run at full speed. Each step lasted for 2 minutes, except the last step, in which the children were instructed to maintain as long as possible. RESULTS: A total of 104 children (64 female/35 male, mean age 6.6 years) performed outdoor cardiopulmonary exercise testing using a mobile device. Almost all tests were completed successfully (95%). Despite a predominance of female study subjects, anthropometric values did not differ between boys and girls. V̇O2peak/kg, respiratory exchange ratio, VT1, heart rate at VT1, and time of exercise were also comparable between sexes. Generally, a tendency of higher maximal oxygen uptake could be observed in older children. CONCLUSION: Open field mobile cardiopulmonary exercise testing represents a novel approach in very young children. In this study, we were able to determine normal values of maximal oxygen uptake and OUES/kg for 4-8-year-old children. The method is easy to achieve and safe.


Subject(s)
Exercise Test , Oxygen Consumption , Humans , Child , Male , Female , Child, Preschool , Reference Values , Oxygen Consumption/physiology , Exercise/physiology , Oxygen