Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 3 de 3
Filter
Add more filters










Database
Language
Publication year range
1.
Eur Urol Oncol ; 2024 May 28.
Article in English | MEDLINE | ID: mdl-38811250

ABSTRACT

BACKGROUND: Hematuria is a cardinal symptom of urinary tract cancer and would require further investigations. OBJECTIVE: To determine the ability of renal bladder ultrasound (RBUS) with the Hematuria Cancer Risk Score (HCRS) to inform cystoscopy use in patients with hematuria. DESIGN, SETTING, AND PARTICIPANTS: The development cohort comprised 1984 patients with hematuria from 40 UK hospitals (DETECT 1; ClinicalTrials.gov: NCT02676180) who received RBUS. An independent validation cohort comprised 500 consecutive patients referred to secondary care for a suspicion of bladder cancer. OUTCOME MEASUREMENTS AND STATISTICAL ANALYSIS: Sensitivity and true negative of the HCRS and RBUS were assessed. RESULTS AND LIMITATIONS: A total of 134 (7%) and 36 (8%) patients in the development and validation cohorts, respectively, had a diagnosis of urinary tract cancer. Validation of the HCRS achieves good discrimination with an area under the receiver operating characteristic curve of 0.727 (95% confidence interval 0.648-0.800) in the validation cohort with sensitivity of 95% for the identification of cancer. Utilizing the cutoff of 4.500 derived from the HCRS in combination with RBUS in the development cohort, 680 (34%) patients would have been spared cystoscopy at the cost of missing a G1 Ta bladder cancer and a urinary tract cancer patient, while 117 (25%) patients would have avoided cystoscopy at the cost of missing a single patient of G1 Ta bladder cancer with sensitivity for the identification of cancer of 97% in the validation cohort. CONCLUSIONS: The HCRS with RBUS offers good discriminatory ability in identifying patients who would benefit from cystoscopy, sparing selected patient cohorts from an invasive procedure. PATIENT SUMMARY: The hematuria cancer risk score with renal bladder ultrasound allows for the triage of patients with hematuria who would benefit from visual examination of the bladder (cystoscopy). This resulted in 25% of patients safely omitting cystoscopy, which is an invasive procedure, and would lead to health care cost savings.

2.
CVIR Endovasc ; 5(1): 44, 2022 Aug 20.
Article in English | MEDLINE | ID: mdl-35986829

ABSTRACT

BACKGROUND: Stenosis is a common complication of haemodialysis arteriovenous accesses. Endovascular approaches with percutaneous transluminal fistuloplasty have largely replaced open surgical approaches as first line treatment. Vessel rupture is an uncommon complication of fistuloplasty and most reports describe venous rupture. Stent-graft deployment can salvage this, however, its use requires careful assessment of the distal vasculature. Arterial rupture with fistuloplasty has rarely been described in the literature. This is a novel case describing the use of a BeGraft coronary stent-graft to manage juxta-anastomotic arterial rupture and pseudoaneurysm complicating fistuloplasty. CASE PRESENTATION: A 77 year old female with end stage renal failure secondary to systemic amyloid light chain type amyloidosis was referred for a suspected radio-cephalic arteriovenous fistula stenosis after difficulty cannulating with poor flow during dialysis and clinical reduction in the fistula thrill. Both Doppler ultrasound and intravenous fistulography confirmed a venous stenosis 2 cm distal to the anastomosis. The stenosis was treated by fistuloplasty, however, this was complicated by a rupture of the juxta-anastomotic arterial segment intraoperatively. Intermittent balloon tamponade was used to minimise extravasation although a pseudoaneurysm formed within the damaged arterial segment. The patient's distal neurovascular status was assessed using the Barbeau test and we sonographically confirmed adequate retrograde arterial flow via a complete palmar arch directing blood from the ulnar artery. After discussion with the renal transplant team, a 4 mm BeGraft coronary stent-graft was deployed to control haemorrhage and bypass the pseudoaneurysm until adequate haemostasis and fistula flow was achieved. Follow-up 3 months post-procedure reported the patient continued with haemodialysis using the stented fistula with no further complications. CONCLUSIONS: To our knowledge, this is the first case report describing the application of BeGraft coronary stent-grafts to salvage fistuloplasty of a radio-cephalic arteriovenous fistula stenosis complicated by juxta-anastomotic arterial rupture and pseudoaneurysm formation. We demonstrate the safety and short-term efficacy of this technology.

3.
Insights Imaging ; 11(1): 50, 2020 Mar 19.
Article in English | MEDLINE | ID: mdl-32193698

ABSTRACT

OBJECTIVES: To develop a paediatric radiology themed escape room session for undergraduate education and secondly, to determine participant satisfaction and improvement in knowledge. METHODS: A paediatric radiology escape room with accompanying tutorial was developed around key learning objectives set within the RCR and ESR undergraduate curriculum. Students were recruited from two different universities and undertook the escape room themed teaching. An 8-question single best answer (SBA) test was completed before, immediately after and at 2 weeks post-teaching to determine participant improvement and retention of knowledge. The general feedback was also collected. RESULTS: The escape room sessions were held three times, for 19 students (6-7 students per session). All groups completed the escape room in ≤ 20 min. Students enjoyed the experience, assigning an average satisfaction score of 9.4/10 (range 7-10). The majority (17/19, 89.5%) preferred this method of teaching to a lecture-based tutorial alone, although all said they found the tutorial component useful. For the SBA test, there was an average increase in 3.6 marks (range 1-6 marks) per participant between before and after the escape room. This improved knowledge was mostly sustained after 2 weeks, with an average increase of 3.4 marks difference (range 1 to 6) per participant compared to before the teaching. CONCLUSIONS: A paediatric radiology themed escape room is a feasible teaching method, enjoyed by participants and associated with an increase in radiological knowledge. Further work with larger sample size and direct comparison with other traditional teaching methods is required.

SELECTION OF CITATIONS
SEARCH DETAIL
...