Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 8 de 8
Filter
1.
Eur J Heart Fail ; 25(2): 274-283, 2023 02.
Article in English | MEDLINE | ID: mdl-36404397

ABSTRACT

AIMS: Excessive prolongation of PR interval impairs coupling of atrio-ventricular (AV) contraction, which reduces left ventricular pre-load and stroke volume, and worsens symptoms. His bundle pacing allows AV delay shortening while maintaining normal ventricular activation. HOPE-HF evaluated whether AV optimized His pacing is preferable to no-pacing, in a double-blind cross-over fashion, in patients with heart failure, left ventricular ejection fraction (LVEF) ≤40%, PR interval ≥200 ms and either QRS ≤140 ms or right bundle branch block. METHODS AND RESULTS: Patients had atrial and His bundle leads implanted (and an implantable cardioverter-defibrillator lead if clinically indicated) and were randomized to 6 months of pacing and 6 months of no-pacing utilizing a cross-over design. The primary outcome was peak oxygen uptake during symptom-limited exercise. Quality of life, LVEF and patients' holistic symptomatic preference between arms were secondary outcomes. Overall, 167 patients were randomized: 90% men, 69 ± 10 years, QRS duration 124 ± 26 ms, PR interval 249 ± 59 ms, LVEF 33 ± 9%. Neither peak oxygen uptake (+0.25 ml/kg/min, 95% confidence interval [CI] -0.23 to +0.73, p = 0.3) nor LVEF (+0.5%, 95% CI -0.7 to 1.6, p = 0.4) changed with pacing but Minnesota Living with Heart Failure quality of life improved significantly (-3.7, 95% CI -7.1 to -0.3, p = 0.03). Seventy-six percent of patients preferred His bundle pacing-on and 24% pacing-off (p < 0.0001). CONCLUSION: His bundle pacing did not increase peak oxygen uptake but, under double-blind conditions, significantly improved quality of life and was symptomatically preferred by the clear majority of patients. Ventricular pacing delivered via the His bundle did not adversely impact ventricular function during the 6 months.


Subject(s)
Cardiac Resynchronization Therapy , Heart Failure , Male , Humans , Female , Bundle of His , Cross-Over Studies , Stroke Volume , Quality of Life , Exercise Tolerance , Ventricular Function, Left , Oxygen , Treatment Outcome , Cardiac Pacing, Artificial/methods , Cardiac Resynchronization Therapy/methods , Electrocardiography/methods
2.
Europace ; 24(5): 796-806, 2022 05 03.
Article in English | MEDLINE | ID: mdl-35079787

ABSTRACT

AIMS: To determine whether triventricular (TriV) pacing is feasible and improves CRT response compared to conventional biventricular (BiV) pacing in patients with left bundle branch block (LBBB) and intermediate QRS prolongation (120-150 ms). METHODS AND RESULTS: Between October 2015 and November 2019, 99 patients were recruited from 11 UK centres. Ninety-five patients were randomized 1:1 to receive TriV or BiV pacing systems. The primary endpoint was feasibility of TriV pacing. Secondary endpoints assessed symptomatic and remodelling response to CRT. Baseline characteristics were balanced between groups. In the TriV group, 43/46 (93.5%) patients underwent successful implantation vs. 47/49 (95.9%) in the BiV group. Feasibility of maintaining CRT at 6 months was similar in the TriV vs. BiV group (90.0% vs. 97.7%, P = 0.191). All-cause mortality was similar between TriV vs. BiV groups (4.3% vs. 8.2%, P = 0.678). There were no significant differences in echocardiographic LV volumes or clinical composite scores from baseline to 6-month follow-up between groups. CONCLUSION: Implantation of two LV leads to deliver and maintain TriV pacing at 6 months is feasible without significant complications in the majority of patients. There was no evidence that TriV pacing improves CRT response or provides additional clinical benefit to patients with LBBB and intermediate QRS prolongation and cannot be recommended in this patient group. CLINICAL TRIAL REGISTRATION NUMBER: Clinicaltrials.gov: NCT02529410.


Subject(s)
Cardiac Resynchronization Therapy , Heart Failure , Bundle-Branch Block/diagnosis , Bundle-Branch Block/therapy , Cardiac Resynchronization Therapy/adverse effects , Cardiac Resynchronization Therapy/methods , Heart Failure/diagnosis , Heart Failure/therapy , Humans , Prospective Studies , Treatment Outcome
3.
Heart Rhythm O2 ; 2(1): 19-27, 2021 Feb.
Article in English | MEDLINE | ID: mdl-34113901

ABSTRACT

BACKGROUND: No periprocedural metric has demonstrated improved cardiac resynchronization therapy (CRT) outcomes in a multicenter setting. OBJECTIVE: We sought to determine if left ventricular (LV) lead placement targeted to the coronary sinus (CS) branch generating the best acute hemodynamic response (AHR) results in improved outcomes at 6 months. METHODS: In this multicenter randomized controlled trial, patients were randomized to guided CRT or conventional CRT. Patients in the guided arm had LV dP/dtmax measured during biventricular (BIV) pacing. Target CS branches were identified and the final LV lead position was the branch with the best AHR and acceptable threshold values. The primary endpoint was the proportion of patients with a reduction in LV end-systolic volume (LVESV) of ≥15% at 6 months. RESULTS: A total of 281 patients were recruited across 12 centers. Mean age was 70.8 ± 10.9 years and 54% had ischemic etiology. Seventy-three percent of patients in the guided arm demonstrated a reduction in LVESV of ≥15% at 6 months vs 60% in the conventional arm (P = .02). Patients with AHR ≥ 10% were more likely to demonstrate a reduction of ESV ≥ 15% (84% of patients with an AHR ≥10% vs 28% with an AHR <10%; P < 0.001). Procedure duration and fluoroscopy times were longer in the pressure wire-guided arm (104 ± 39 minutes vs 142 ± 39 minutes; P < .001 and 20 ±16 minutes vs 28 ± 15 minutes; P = .002). CONCLUSIONS: AHR determined by invasively measuring LV dP/dtmax during BIV pacing predicts reverse remodeling 6 months after CRT. Patients in whom LV dP/dtmax was used to guide LV lead placement demonstrated better rates of reverse remodeling.

6.
Pacing Clin Electrophysiol ; 41(5): 546-552, 2018 05.
Article in English | MEDLINE | ID: mdl-29572881

ABSTRACT

PURPOSE: Many centers perform day-case cardiac rhythm management (CRM) device implantation. However, there is a paucity of prospective data concerning this approach. We performed a prospective single-center study of day-case device implantation, including data on patient satisfaction. METHODS: All patients scheduled for a new elective device were considered for a day-case procedure. Exclusion criteria were living alone or without a suitable carer, advancing age/frailty, a metallic valve, and persistent complete heart block. Following discharge, patients were reviewed in device clinic at 6 weeks with an anonymized questionnaire. RESULTS: During the study period (May 2014-August 2016), 797 new CRM devices were implanted. Of these, 232 were elective and included in the analysis; 101 were planned to be day-case and 131 scheduled for overnight stay. Of the 101 day-case patients, 52 had a pacemaker, 28 an implantable cardioverter defibrillator (ICD), 16 a cardiac resynchronization therapy pacemaker/defibrillator, and five a subcutaneous-ICD. Complications were similar in the day-case (n  =  12, 12%) and overnight stay (n  =  15, 11%) groups (P  =  0.92). In the day-case group, 93 (92%) patients went home the same day. An estimated 111 overnight bed days were saved, translating to a cost saving of £61,912 (euro 70,767, $79,211). Note that 99% (n  =  100) of patients returned the questionnaire. Patient satisfaction was universally high. The majority (n  =  98, 98%) felt ready to go home on discharge; only a minority (n  =  5, 5%) would have preferred an overnight stay. CONCLUSIONS: A significant proportion of elective new CRM device implants can be performed as day-case procedures. With appropriate selection patient acceptability of same-day discharge is high.


Subject(s)
Ambulatory Care , Defibrillators, Implantable , Patient Satisfaction , Aged , Female , Humans , Male , Prospective Studies , Surveys and Questionnaires , Treatment Outcome
7.
J Interv Card Electrophysiol ; 49(2): 181-189, 2017 Aug.
Article in English | MEDLINE | ID: mdl-28386821

ABSTRACT

PURPOSE: Patients at high non-sudden cardiac death risk may gain no significant benefit from implantable cardioverter-defibrillator (ICD) therapy. A number of approaches have been proposed to identify these patients, including single clinical markers and more complex scoring systems. The aims of this study were to use the proposed scoring systems to (1) establish how many current ICD recipients may be too high risk to derive significant benefit from ICD therapy and (2) evaluate how well the scoring systems predict short-term mortality in an unselected ICD cohort. METHODS: We performed a single-centre retrospective observational study of all new ICD implants over 5 years (2009-2013). We used four published scoring systems (Bilchick, Goldenberg, Kramer and Parkash) and serum urea to identify new ICD recipients whose short-term predicted mortality risk was high. We evaluated how well the scoring systems predicted death. RESULTS: Over 5 years, there were 406 new implants (79% male, mean age 70 (60-76), 58% primary prevention). During a follow-up of 936 ± 560 days, 96 patients died. Using the scoring systems, the proportion of ICD recipients predicted to be at high short-term mortality risk were 5.9% (Bilchick), 34.7% (Goldenberg), 7.4% (Kramer), 21.4% (Parkash) and 25% (urea, cut-off of >9.28 mM). All four risk scores predicted mortality (P < 0.0001); however, none outperformed urea for the prediction of 1- or 3-year mortality. CONCLUSIONS: Using published scoring systems, a significant proportion of current ICD recipients are at high short-term mortality risk. Although all four scoring systems predicted mortality during follow-up, none significantly outperformed serum urea.


Subject(s)
Death, Sudden, Cardiac/prevention & control , Defibrillators, Implantable , Patient Selection , Primary Prevention , Risk Assessment , Aged , Biomarkers , Female , Humans , London , Male , Middle Aged , Retrospective Studies , Risk Factors
8.
J Interv Card Electrophysiol ; 46(3): 335-43, 2016 Sep.
Article in English | MEDLINE | ID: mdl-27259568

ABSTRACT

PURPOSE: Randomised trials have shown that empiric ICD programming, using long detection times and high detection zones, reduces device therapy in ICD recipients. However, there is less data on its effectiveness in a "real-world" setting, especially secondary prevention patients. Our aim was to evaluate the introduction of a standardised programming protocol in a real-world setting of unselected ICD recipients. METHODS: We analysed 270 consecutive ICD recipients implanted in a single centre-135 implanted prior to protocol implementation (physician-led group) and 135 after (standardised group). The protocol included long arrhythmia detection times (30/40 or equivalent) and high rate detection zones (primary prevention lower treatment zone 200 bpm). Programming in the physician-led group was at the discretion of the implanter. The primary endpoint was time-to-any therapy (ATP or shocks). Secondary endpoints were time-to-inappropriate therapy and time-to-appropriate therapy. The safety endpoints were syncopal episodes, hospital admissions and death. RESULTS: At 12 months follow-up, 47 patients had received any ICD therapy (physician-led group, n = 31 vs. standardised group, n = 16). There was a 47 % risk reduction in any device therapy (p = 0.04) and an 86 % risk reduction in inappropriate therapy (p = 0.009) in the standardised compared to the physician-led group. There was a non-significant 30 % risk reduction in appropriate therapy (p = 0.32). Results were consistent across primary and secondary prevention patients. There were no significant differences in the rates of syncope, hospitalisation, and death. CONCLUSIONS: In unselected patients in a real-world setting, introduction of a standardised programming protocol, using long detection times and high detection zones, significantly reduces the burden of ICD therapy without an increase in adverse outcomes.


Subject(s)
Defibrillators, Implantable/statistics & numerical data , Defibrillators, Implantable/standards , Heart Failure/mortality , Heart Failure/prevention & control , Practice Guidelines as Topic , Therapy, Computer-Assisted/standards , Aged , Causality , Diagnosis, Computer-Assisted/mortality , Diagnosis, Computer-Assisted/standards , Diagnosis, Computer-Assisted/statistics & numerical data , Electric Injuries/mortality , Electric Injuries/prevention & control , Female , Guideline Adherence/statistics & numerical data , Heart Failure/diagnosis , Humans , Male , Medical Errors/prevention & control , Medical Errors/statistics & numerical data , Prevalence , Quality of Life , Retrospective Studies , Risk Factors , Survival Rate , Therapy, Computer-Assisted/statistics & numerical data , Treatment Outcome , United Kingdom/epidemiology
SELECTION OF CITATIONS
SEARCH DETAIL
...