1.
Talanta ; 167: 709-713, 2017 May 15.
Article in English | MEDLINE | ID: mdl-28340783

ABSTRACT

A fully automated sugaring-out assisted liquid-liquid extraction procedure was suggested. The procedure was based on the separation of the acetonitrile phase, containing a target analyte from the homogeneous sample solution after injection of sugaring-out reagent (glucose) into a mixing chamber of the flow system. Air bubbling was used to promote the extraction process and phase separation. After the fast phase separation in the mixing chamber, the acetonitrile phase containing the target analyte was transferred to an HPLC-UV system. Under the optimal conditions, the detector response of procainamide was linear in the concentration range of 6×10-7-4×10-5molL-1. The limit of detection, calculated from a blank test based on 3σ, was 2×10-7molL-1. The proposed method was successfully applied for the determination of procainamide in human urine samples and the analytical results agreed fairly well with the results obtained by reference CE method.


Subject(s)
Acetonitriles/chemistry , Automation , Chromatography, High Pressure Liquid/methods , Glucose/chemistry , Liquid-Liquid Extraction/methods , Procainamide/urine , Adolescent , Adult , Female , Healthy Volunteers , Humans , Limit of Detection , Male , Ultraviolet Rays , Young Adult
2.
Electrophoresis ; 37(22): 3017-3019, 2016 11.
Article in English | MEDLINE | ID: mdl-27494259

ABSTRACT

Fast isotopic separation of 10 B and 11 B boric acid by CZE was demonstrated. The BGE contained 25 mM phenylalanine and 5 mM putrescine (рН 8.95). The running conditions were +25 kV at 20°C with indirect photometric detection at 210 nm. Baseline separation was achieved in less than 9 min. RSD of migration times and corrected peak areas were less than 0.5 and 3%, respectively (n = 5). Linearity was demonstrated in the range 0.2-2 mM for 11 B and 0.2-0.5 mM for 10 B.


Subject(s)
Boric Acids/chemistry , Boric Acids/isolation & purification , Electrophoresis, Capillary/methods , Boric Acids/analysis , Hydrogen-Ion Concentration , Isotopes/analysis , Isotopes/chemistry , Isotopes/isolation & purification , Limit of Detection , Linear Models , Reproducibility of Results
3.
Electrophoresis ; 36(24): 3014-7, 2015 Dec.
Article in English | MEDLINE | ID: mdl-26449380

ABSTRACT

Separation of (6)Li and (7)Li isotopes by CZE was demonstrated. The BGE contained 5 mM 4-aminopyridine, 0.9 mM oxalic acid, 0.25 mM CTAB, and 0.25% w/v Tween 20 (рН = 9.2). The running conditions were +25 kV at 30°C with indirect photometric detection at 261 nm. Under optimal experimental conditions, the analysis time was less than 21 min. Separation of Li preparations with mole fraction of (6)Li ranging from 3.44 up to 90.38% was demonstrated.


Subject(s)
Electrophoresis, Capillary/methods , Lithium/chemistry , Lithium/isolation & purification , Cetrimonium , Cetrimonium Compounds , Ions/analysis , Ions/chemistry , Ions/isolation & purification , Isotopes/analysis , Isotopes/chemistry , Isotopes/isolation & purification , Limit of Detection , Lithium/analysis , Polysorbates