Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 13 de 13
Filter
Add more filters










Publication year range
1.
Opt Lett ; 49(11): 2890-2893, 2024 Jun 01.
Article in English | MEDLINE | ID: mdl-38824285

ABSTRACT

We have developed a new, to the best of our knowledge, beam swinging coherent Doppler wind lidar (BS-CDWL) by employing a wavelength switching method using mass-produced components for wavelength division multiplexing (WDM) optical communication systems. This BS-CDWL also has a single and position-to-angle conversion telescope for multiple LOS measurement which contributes to cost-effectiveness. Preliminary wind sensing result is shown with measurable range of up to 350 m.

2.
Appl Opt ; 63(7): 1681-1694, 2024 Mar 01.
Article in English | MEDLINE | ID: mdl-38437267

ABSTRACT

We report performance of a satellite-borne coherent Doppler wind lidar (SCDWL), which equips a planer waveguide amplifier (PWA) operating in a wavelength of 1.5 µm. The performance is defined by detection probability, measurement precision, and bias, and is characterized with a Doppler wind lidar (DWL) simulation that considers a realistic wind velocity profile, and instrumental and atmospheric parameters. Among the parameters, we carefully model those related to the PWA whose figure of merit has great impact on the performance of SCDWL and has shown rapid improvement in recent years. Moreover, we introduce three models for a backscattering coefficient (high, moderate, and low) to assess the influence from variation of atmospheric backscattering. Our simulation demonstrates that the SCDWL can work with reasonable performance for the target altitude of 6 km in the case of the high-backscattering model. The simulation also exhibits that the SCDWL can observe wind velocity at the altitude of 12 km if improved instrumental parameters or higher backscattering coefficients are considered. In addition, we reveal that non-uniform wind velocity distribution degrades the performance of the SCDWL and induces a bias between measured and real wind velocity.

3.
Opt Express ; 30(11): 20038-20062, 2022 May 23.
Article in English | MEDLINE | ID: mdl-36221764

ABSTRACT

The intelligent and compact coherent Doppler lidar (CDL) for wind sensing is demonstrated. The configuration is fiber-based. Several functions for the robust wind sensing in various atmospheric and environmental conditions are shown. The main feature of this CDL is the intelligent functions of the beam focusing, spectral accumulation, and window wiping. The supplemental functions of the robust noise floor reduction and motion compensation are also introduced. The effect of the above-mentioned main feature is demonstrated for the improvement of data availability. The evaluation results of the highly accurate wind velocity measurement are additionally shown.

4.
Appl Opt ; 61(2): 352-361, 2022 Jan 10.
Article in English | MEDLINE | ID: mdl-35200869

ABSTRACT

We have developed an active alignment of receiving beam (AARB) function for coaxial optics in wind sensing coherent Doppler lidar using feedback control based on the heterodyne-detected signal processing of backscattered light from the aerosols. The proposed method needs only the simple alignment components and contributes to the robustness for the coherent lidars with the high-power laser transmitter under the risky condition of misalignment, for example, in the airborne application. The concept, design, and evaluation results of the alignment precision are shown. The effect of the AARB is demonstrated for both cases of the hard target and soft target (i.e., wind sensing). To the best of our knowledge, this is the first demonstration of the AARB concept for the wind sensing coherent lidar.

5.
Opt Express ; 28(18): 27078-27096, 2020 Aug 31.
Article in English | MEDLINE | ID: mdl-32906968

ABSTRACT

The 1.53-µm coherent differential absorption lidar (DIAL) is demonstrated for the simultaneous profiling of water vapor (H2O) density and wind speed. The optical setup is fiber-based. The wavelength locking circuit can achieve precise locking of 13.0 MHz by the combination of the line center locking to the hydrogen cyanide (HCN) absorption line and offset locking to the H2O absorption wavelength. The measurable range for the simultaneous profiling is up to 1.2 km. The DIAL-measured H2O density is compared with the one measured by an in-situ sensor. Qualitative good agreement is shown with the random error of 0.56 g/m3.

6.
Appl Opt ; 59(8): 2238-2247, 2020 Mar 10.
Article in English | MEDLINE | ID: mdl-32225753

ABSTRACT

A feasibility study of coherent differential absorption lidar is conducted using a 1.53-µm wavelength for simultaneously retrieving the water vapor density and wind speed profiles. We selected the ON and OFF wavelengths to be 1531.383 and 1531.555 nm, respectively, for minimizing the effect of the temperature change in the atmosphere. The systematic measurement error can be reduced to below 5% by stabilizing the ON wavelength from ${-64}$-64 to 102 MHz around the center of the water vapor absorption line. Analysis of the speckle and photon statistics errors reveal that the relative error of the water vapor density is less than 10% at the altitude from 0.1 to 1.7 km with the 100 m range resolution with 10 min data accumulation time. The simultaneous measurement of wind speed and direction can also be achieved by employing a conical scan mechanism.

8.
Opt Express ; 27(17): 24175-24187, 2019 Aug 19.
Article in English | MEDLINE | ID: mdl-31510311

ABSTRACT

We have developed a high-gain, high-peak-power laser amplifier at an eye-safe 1.55 µm wavelength using an Er,Yb:glass planar waveguide for wind sensing coherent Doppler lidars (CDLs). Our planar waveguide is free from stimulated Brillouin scattering and realizes high gain thanks to its multi-bounce optical-path configuration. A peak power of 5.5 kW with a pulse energy of 3.2 mJ is achieved at the repetition frequency of 4 kHz, which leads to an average power of 12.8 W. The gain is more than 23 dB. The wind sensing at more than 30 km is demonstrated with a CDL using the developed amplifier.

9.
Opt Lett ; 37(13): 2688-90, 2012 Jul 01.
Article in English | MEDLINE | ID: mdl-22743496

ABSTRACT

We have demonstrated the laser-absorption spectrometer system using frequency chirped intensity modulation at 1.57 µm wavelength for measurement of CO(2) concentration. Using this technique, backscattered laser radiation from different ranges can be discriminated in the frequency domain of the electrical signal. We have reported the discrimination of two signals from the targets with different ranges. It is shown that stable measurements with short time fluctuation corresponding to 4 ppm (rms) were obtained with 32 s measurement intervals. Furthermore, there is qualitative good agreement on, at least, the diurnal changes between the results of the laser absorption spectrometer system and the in-situCO(2) sensor.

10.
Appl Opt ; 50(14): 2055-68, 2011 May 10.
Article in English | MEDLINE | ID: mdl-21556107

ABSTRACT

A feasibility study is carried out on a 1.6 µm continuous-wave modulation laser absorption spectrometer system for measurement of global CO(2)concentration from a satellite. The studies are performed for wavelength selection and both systematic and random error analyses. The systematic error in the differential absorption optical depth (DAOD) is mainly caused by the temperature estimation error, surface pressure estimation error, altitude estimation error, and ON wavelength instability. The systematic errors caused by unwanted backscattering from background aerosols and dust aerosols can be reduced to less than 0.26% by using a modulation frequency of around 200 kHz, when backscatter coefficients of these unwanted backscattering have a simple profile on altitude. The influence of backscattering from cirrus clouds is much larger than that of dust aerosols. The transmission power required to reduce the random error in the DAOD to 0.26% is determined by the signal-to-noise ratio and the carrier-to-noise ratio calculations. For a satellite altitude of 400 km and receiving aperture diameter of 1 m, the required transmission power is approximately 18 W and 70 W when albedo is 0.31 and 0.08, respectively; the total measurement time in this case is 4 s, which corresponds to a horizontal resolution of 28 km.

11.
Appl Opt ; 50(11): 1560-9, 2011 Apr 10.
Article in English | MEDLINE | ID: mdl-21478929

ABSTRACT

In a previous study, we developed a 1.6 µm continuous-wave (cw) modulation laser absorption spectrometer system for CO(2) sensing and demonstrated the measurement of small fluctuations in CO(2) corresponding to a precision of 4 parts per million (ppm) with a measurement interval of 32 s. In this paper, we present the process to achieve this highly specific measurement by introducing important points, which have not been shown in the previous study. Following the results of preliminary experiments, we added a function for speckle averaging on the optical antenna unit. We additionally came up with some ideas to avoid the influences of etalon effects and polarization dependence in optical components. Because of the new functions, we realized a calibration precision of 0.006 dB (rms), which corresponds to a CO(2) concentration precision of less than 1 ppm for a 2 km path. We also analyzed the CO(2) sensing performance after the improvements described above. The measured short time fluctuation of the differential absorption optical depth was reasonably close to that calculated using the carrier-to-noise ratio of the received signal.

12.
Appl Opt ; 49(27): 5169-74, 2010 Sep 20.
Article in English | MEDLINE | ID: mdl-20856293

ABSTRACT

We present a semianalytic pulsed coherent laser radar (CLR) equation for coaxial and apertured systems. It combines the conventional CLR equation, numerical Fresnel integration (NFI), and nearest Gaussian approximation, using correction factors that correspond to beam truncation. The range dependence of the signal-to-noise ratio obtained by this semianalytic equation was found to agree well with the precise NFI solution for not only the focal range, but also the near-field range. Furthermore, the optimum beam truncation condition depending on the atmospheric refractive index structure constant is shown. The derived equation is useful for precisely predicting the CLR performance simply by its semianalytic expression.

13.
Opt Lett ; 34(10): 1513-5, 2009 May 15.
Article in English | MEDLINE | ID: mdl-19448805

ABSTRACT

We have demonstrated the 1.6 mum cw modulation hard-target differential absorption lidar system for CO(2) sensing. In this system, ON and OFF wavelength laser lights are intensity modulated with cw signals. Received lights of the two wavelengths from the hard target are discriminated by modulation frequencies in the electrical signal domain. The optical circuit is fiber based, and this makes the system compact and reliable. It is shown that a stable CO(2) concentration measurement corresponding to a fluctuation of 4 ppm (rms) (ppm is parts per million) has been achieved in 32 s measurement intervals and the 1 km path.

SELECTION OF CITATIONS
SEARCH DETAIL
...