Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 2 de 2
Filter
Add more filters










Database
Language
Publication year range
1.
J Clin Pharmacol ; 63(9): 1002-1008, 2023 09.
Article in English | MEDLINE | ID: mdl-37114401

ABSTRACT

Hypersensitivity reactions induced by nonionic iodine contrast media sometimes occur and can be life threatening. However, independent factors affecting their occurrence remain to be fully established. Therefore, the purpose of this study was to clarify independent factors affecting the occurrence of hypersensitivity reactions induced by nonionic iodine contrast media. Patients who received nonionic iodine contrast media at Keiyu Hospital from April 2014 to December 2019 were included. The adjusted odds ratio (OR) and 95% confidence interval (CI) for factors affecting hypersensitivity reactions induced by contrast media were calculated by logistic regression analysis. The multiple imputation method was used to impute missing data. Hypersensitivity reactions occurred in 0.72% (163 cases) of 22,695 cases enrolled in this study. In univariate analysis, 10 variables met the criteria of P < .05 and proportion of missing data <50%. In multivariate analysis, age (OR, 0.98; 95% CI, 0.97-0.99), outpatient status (OR, 2.08; 95% CI, 1.20-3.60), contrast medium iodine content (OR, 1.02; 95% CI, 1.01-1.04), history of drug allergy (OR, 2.41; 95% CI, 1.50-3.88), and asthma (OR, 17.4; 95% CI, 7.53-40.1) were identified as independent factors affecting contrast media-induced hypersensitivity reactions. Among these factors, history of drug allergy and asthma appear to be clinically relevant and reliable due to their high OR and plausible biological mechanisms, but the other three factors require further validation.


Subject(s)
Asthma , Drug Hypersensitivity , Hypersensitivity , Iodine , Humans , Iodine/adverse effects , Contrast Media/adverse effects , Drug Hypersensitivity/epidemiology , Drug Hypersensitivity/etiology
2.
Support Care Cancer ; 28(12): 5953-5961, 2020 Dec.
Article in English | MEDLINE | ID: mdl-32281031

ABSTRACT

PURPOSE: Incorporation of patient-generated health data (PGHD) into clinical research requires an investigation of the validity of outcomes and feasibility of implementation. This single-arm pilot trial investigated the feasibility of using a commercially available activity tracking wearable device in cancer patients to assess adherence to the device and real-time PGHD collection in a clinical research setting. METHODS: From July to November 2017, enrolled adult patients were asked to wear a wristband-style device. Brief Fatigue Inventory (BFI) and MD Anderson Symptom Inventory (MDASI) were assessed at baseline and on day 29. Furthermore, 29-day Pittsburgh Sleep Quality Index, global impression of the devices, and NCI CTCAE v4 were evaluated. RESULTS: Of 30 patients (mean age, 58.6 years; male, 21 [70%]), 15 (50%) and 11 (36.7%) had gastrointestinal and lung cancer, respectively, and 27 (90%, 95% CI: 0.74-0.98) were well adhered (> 70%) to the device for 28 days. The mean adherence was 84.9% (range: 41.7-95.2%). More frequent PGHD synchronization tended to show better device adherence, with moderate correlation (r = 0.62, 95% CI: 0.33-0.80, p < 000.1). CONCLUSIONS: The feasibility of using a wearable activity tracker was confirmed in cancer patients receiving chemotherapy for a month. For future implementation in clinical trials, there is a need for further comprehensive assessment of the validity and reliability of wearable activity trackers. TRIAL REGISTRATION: This trial was registered at the University Hospital Medical Information Network Clinical Trials Registry as UMIN: UMIN000027575.


Subject(s)
Activities of Daily Living , Fitness Trackers/statistics & numerical data , Neoplasms/drug therapy , Patient Compliance/statistics & numerical data , Adult , Aged , Antineoplastic Agents/therapeutic use , Data Collection , Feasibility Studies , Female , Humans , Japan , Male , Middle Aged , Reproducibility of Results
SELECTION OF CITATIONS
SEARCH DETAIL
...